APC Rack Mount PDU, Metered 208V/60A Three-Phase PDU, (18) Outlets, 0U Vertical Rackmount (AP8866)
- 208V Input, Metered 3Ph 60A rackmount Power Distribution Unit
- Input: IEC-309 60A 3P+PE (17.3 kW)
- Output Receptacles: Twelve (12) C19 Outlets, Six (6) C13 Outlets
- 0U Vertical Mounting PDU
- Cord Length: 5.9'
Overview
Specs
Reviews
RACK PDU 2G 208VAC 0U METERED 17.2KW 6 C13 AND 12 C19
Warranty & Returns
Warranty, Returns, And Additional Information
Return Policies*
- Return for refund within: 30 days
- Returns are subject to restocking fees and return shipping fees. Please click here to learn more about restocking fees and return shipping fees.
- This item is covered by Newegg.com's International Order Return Policy.
- Read full return policy for details.
- *Subject to applicable law
Warranty Notice:
This product does not include manufacturer warranty when purchased or used outside of its designated sales region. By purchasing internationally, you acknowledge that warranty support from the manufacturer will not be available.
Manufacturer Contact Info
- Manufacturer Product Page
- Manufacturer Website
- Support Phone: 1-800-555-2725
- Support Website
- View other products from APC
LOADING...
LOADING...
The APC AP8866 is a metered, 0U vertical rack PDU for 208V three-phase power, suited to data-center and enterprise rack installations that need to distribute power to multiple servers or network devices through 12 C19 and 6 C13 outlets.
Recommended For
- Data-center operators powering high-density 208V server racks can use the AP8866 to distribute power through its 12 C19 and 6 C13 outlets, with up to 17.2 kW listed capacity.
- Rack administrators who need to check connected load remotely can use its metering for real-time monitoring while powering servers, switches, and network devices.
- Teams equipping a rack with a compatible 208V three-phase IEC 60309 60A feed can use this vertical 0U PDU to distribute power without occupying rack-unit space.
- Operators powering a mix of equipment with C13 and C19 power cords can use its combination of six C13 and twelve C19 outlets; the outlet mix is suited to planning loads across its banks.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | Metered three-phase power distribution in a 0U vertical rack, for equipment with C13 or C19 power connections |
| Input And Electrical Ratings | 208V input at 50/60 Hz with an IEC 309 60A 3P+PE connector; rated for 60A per phase, with 48A maximum line current per phase after regulatory derating and a 17.3 kVA load capacity |
| Output And Outlets | 208V output across 18 outlets: 12 IEC 320 C19 and 6 IEC 320 C13; listed output power is 17.2 kW |
| Mounting And Physical Specifications | 0U vertical rackmount form factor; 6 ft cord, 72.01 × 2.2 × 2.01 in dimensions, 20.94 lb weight, black |
| Protection | Overload protection included |
| Operating And Storage Environment | Operating humidity: 5–95%; operating elevation: 0–3,000 m. Storage temperature: −25–65 °C, humidity: 5–95%, and elevation: 0–15,000 m |
| Model Identifiers | APC model AP8866 |