CEM DT-9812 1000A AC Leakage Current Tester Large LCD Display with Backlight
Notice:
The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.
At the same time, please forgive us that we are unable to provide the English user manual. If you need it, please contact the customer service after purchase.
Thanks for your support!
1000A AC Leakage Current Tester
Large tranceformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
Frequency filter switch to eliminate the effect of the harmonics.
Measurement from mA up to AC 1000A
True RMS enables an accurate measurement for distorted waveforms.
Peak hold function
Data hold function: Allows for easy reading in dimly light or hard-to-reach locations
Large LCD display with backlight
International safety standard IEC61010-1 CAT.III 600V
Features
Large tranceformer jaws of 68mm diameter makes it possible to clamp on all three or four wires (3 phases) together for leakage current measurement.
Frequency filter switch to eliminate the effect of the harmonics.
Measurement from mA up to AC 1000A
True RMS enables an accurate measurement for distorted waveforms.
Peak hold function
Data hold function: Allows for easy reading in dimly light or hard-to-reach locations
Large LCD display with backlight
International safety standard IEC61010-1 CAT.III 600V
Size (H x W x D): 250mm x 113mm x 45mm
Weight: 490g
Specifications
Function Range Range Accuracy(50/60Hz) Accuracy(40~1kHz)
AC Current 200mA 0.1mA ±(1.5%+10d) ±(3.0%+10d)
2A 1mA ±(1.5%+10d) ±(3.0%+10d)
20A 10mA ±(1.5%+10d) ±(3.0%+10d)
200A 100mA ±(2.0%+10d) ±(3.5%+10d)
1000A 1A ±(5.5%+10d) ±(10%+10d)
AC Voltage 600V 0.1V ±(1.0%+5d)
DC Voltage 600V 0.1V ±(1.0%+5d)
Resistance 600? 0.1? ±(1.0%+5d)
Continuity Test Threshold 40?, Continuity Beeper 2KHz
Conductor size F68mm max.
Frequency response 40Hz-1kHz
Effect of external stray magnetic ?eld F15mm 100A 10mA AC max.
Applicable standards IEC 61010-1 CAT.? 600V