Important instruction: This CM2K0R clamp meter can not test DC Current.
Note: The clamp Jaw is only used to measure current. Do not measure voltage by clamping the conductor being measured. To measure the current, you need to clamp the meter around one of the wires and not the whole power cord. The power cord contains two wires carrying current and a ground wire. The current in the two wires always flows in opposite directions, so the magnetic fields from the two wires cancel each other; therefore, the meter reads 0 A.
The NCV function can test the voltage without contact. When the Meter senses a weak AC signal, the green indicator light will be on and the buzzer will emit a slow, audible beep. When the Meter senses a strong AC signal, the red indicator light will be on and the buzzer will emit a quick beep.

PLEASE ATTENTION
Incorrect operations may cause no work or inaccurate readings:
- Incorrect current: The conductor to be tested is not in the center of the clamp head. (Refer to the right picture for correct use.)
- Incorrect voltage: The plugs of test leads are not fully inserted or not inserted into the correct sockets. It will cause incorrect voltage readings or the clamp meter may not work.
- Doesn't work: Clamp the whole power cord when measuring the current. You need to clamp the meter around one of the wires.


Versatile Clamp Meter
CM2KOR Clamp Meter can accurately measure AC/DC Voltage, AC Current, Resistance, Capacitance etc.

Detects Live Wires
Live wire testing with the red test lead. When it detects a live wire, the clamp meter will reflect with the audio alarm

Backlit LCD and Flashlight
The Backlit LCD and Flashlight ensure clear measuring in a dimly area.

Correct Measurement
Please measure in the correct way, otherwise the readings will not be accurate.

NCV Detection
It features NCV testing with a sound and light alarm. When the indicator light is on, it means there is voltage, please pay attention to your safety.

Continuity Test
Connect test leads to the circuit, the buzzer inside the Meter will beep if the resistance<50O

Convenient battery replacement
Built-in 2×AAA (1.5V) batteries, it can last longer and provide convenient battery replacement.

Automatic Shutdown
If the meter is not in operation for 15 minutes, it will turn off automatically.

Important instruction: This CM2K0R clamp meter can not test DC Current.
Note: The clamp Jaw is only used to measure current. Do not measure voltage by clamping the conductor being measured. To measure the current, you need to clamp the meter around one of the wires and not the whole power cord. The power cord contains two wires carrying current and a ground wire. The current in the two wires always flows in opposite directions, so the magnetic fields from the two wires cancel each other; therefore, the meter reads 0 A.
The NCV function can test the voltage without contact. When the Meter senses a weak AC signal, the green indicator light will be on and the buzzer will emit a slow, audible beep. When the Meter senses a strong AC signal, the red indicator light will be on and the buzzer will emit a quick beep.


PLEASE ATTENTION
Incorrect operations may cause no work or inaccurate readings:
- Incorrect current: The conductor to be tested is not in the center of the clamp head. (Refer to the right picture for correct use.)
- Incorrect voltage: The plugs of test leads are not fully inserted or not inserted into the correct sockets. It will cause incorrect voltage readings or the clamp meter may not work.
- Doesn't work: Clamp the whole power cord when measuring the current. You need to clamp the meter around one of the wires.

Versatile Clamp Meter
CM2KOR Clamp Meter can accurately measure AC/DC Voltage, AC Current, Resistance, Capacitance etc.

Detects Live Wires
Live wire testing with the red test lead. When it detects a live wire, the clamp meter will reflect with the audio alarm

Backlit LCD and Flashlight
The Backlit LCD and Flashlight ensure clear measuring in a dimly area.

Correct Measurement
Please measure in the correct way, otherwise the readings will not be accurate.

NCV Detection
It features NCV testing with a sound and light alarm. When the indicator light is on, it means there is voltage, please pay attention to your safety.

Continuity Test
Connect test leads to the circuit, the buzzer inside the Meter will beep if the resistance<50O

Convenient battery replacement
Built-in 2×AAA (1.5V) batteries, it can last longer and provide convenient battery replacement.

Automatic Shutdown
If the meter is not in operation for 15 minutes, it will turn off automatically.
| Digital Display | 3,½, 2000 |
|---|---|
| Sampling Speed | 3 times per second |
| LCD Size | 35 x 25mm |
| Range Selection | Auto or Manual |
| Overload Indication | “OL” Displayed |
| Working Environment | 32°F~104°F (0°C~40°C); <80% RH |
| Storage Temperature | 14°F~122°F (-10°C~6°C); <70% RH |
| Power | 1.5V AAA Batteries x 2 Included |
| Dimensions | 195x68x29mm |
| Weight | Approx. 203g |
| Safety/Compliances | CAT.III 600V; Pollution Level: 2; Altitude <2000m |
| DC Voltage | 2V/20V/200V/600V ±(0.5%+5) |
| AC Voltage | 2V/20V/200V/600V ±(1.0%+5) |
| AC Current | 2A/20A/200A/400A, 50~60Hz : ±(2.5 +5), Other : ±(3.0% +10) |
| Resistance | 200O/2KO/20KO/200KO/2MO/20MO ±(1.0%+5) |
| Capacitance | 2nF/20nF/200nF/2µF/20µF/200µF/2mF ±(4.0%+5) |