Why does my multimeter not show results?
1) The plugs of test leads are not fully inserted or not inserted into the correct sockets. Please refer to the manual to reinsert them. 2) Please make sure the dial is set to the correct range.
What should I do if this item does not work?
Incorrect testing may have caused the fuse to blow. Please replace it with new fuses.
Does it work for Low voltage?
Note: This multimeter can not measure AC voltage below 100mV. It does not apply to scenarios such as body voltage.

AstroAI Multimeter Series
Specifications


Why does my multimeter not show results?
1) The plugs of test leads are not fully inserted or not inserted into the correct sockets. Please refer to the manual to reinsert them. 2) Please make sure the dial is set to the correct range.
What should I do if this item does not work?
Incorrect testing may have caused the fuse to blow. Please replace it with new fuses.
Does it work for Low voltage?
Note: This multimeter can not measure AC voltage below 100mV. It does not apply to scenarios such as body voltage.

AstroAI Multimeter Series
![]() AM33D Multimeter | ![]() DM200M Multimeter | ![]() M4K0R Multimeter | ![]() DM6000AR Multimeter | ![]() MUS10KRD Smart Multimeter | ![]() CM600 Clamp Meter | ![]() Higher Resolution DM2000 |
|---|---|---|---|---|---|---|
| Customer Reviews | ||||||
| — | — | — | — | — | — | — |
| Price | ||||||
| — | — | — | — | — | — | — |
| Maximum Display | ||||||
| 2000 Counts | 2000 Counts | 4000 Counts | 6000 Counts | 10000 Counts & Carrying case | 6000 Counts | 20000 Counts & Carrying case |
| Range Selection | ||||||
| Manual | Manual | Auto | Manual and Auto | Manual and Smart Auto | Manual and Auto | Auto |
| AC/DC Voltage | ||||||
| ? | ? | ? | ? | AC 750v / DC 1000v | 750V AC /1000V DC | DC V Accuracy: ±(0.08% + 5) |
| AC/DC Current | ||||||
| Only DC Current | ? | ? | ? | — | 1000A AC/DC | ? |
| Resistance/Continuity | ||||||
| ? | ? | ? | ? | ? | ? | ? |
| Diode | ||||||
| ? | ? | ? | ? | ? | ? | ? |
| Capacitance/Frequency | ||||||
| X | X | Only Capacitance | ? | ? | ? | ? |
| Temperature | ||||||
| X | X | X | ? | ? | ? | ? |
| Inrush | ||||||
| X | X | X | X | X | ? | X |
| VFD / LoZ | ||||||
| X | X | X | X | X | ? | X |
Specifications
| Environmental Conditions | CAT II 600 V; CAT Ill 300 V |
|---|---|
| Pollution Level | 2 |
| Temperature and Humidity | 32-104 ° F (0-40 °C);(<80% RH, <10 °C RH) |
| Range Selection | Manual |
| Fuse Protection | mA: F250 mA/250 V Fuse;10 A: F10 A/250 V Fuse |
| Sample Speed | 3 Times Per Second |
| Digital Display | 2000 Counts. The unit symbols will automatically appear according to the measured functions |
| Overload Indication | "OL" Displayed |
| Power | 2 x 1.5 V AAA Batteries |
| DC Voltage | 200mV/2V/20V/200V/600V ±(0.5%+3) |
| AC Voltage | 200V/600V ±(0.8%+5) |
| DC Current | 200µA/200mA/10A ±(1.2% +3) |
| Resistance | 200O/2KO/20KO/200KO ±(1.0%+3);20MO ±(1.5%+3) |