CONTEC PM50 handheld Patient Monitor,NIBP+SPO2+PR+Adult cuffs,USB PC software 24h recorder

In stock.
Ships from China.
Most customers receive within 5-32 days.
  • Heart Rate Monitor
  • White
  • 376*239*65mm
Overview
Specs
Reviews
Introduction PM50 is a multifunctional patient monitor, it can monitor SPO2 and NIBP for a long time, and applies to the hospital wards or family daily health care. Features ¦Compact and portable, easy to use ¦With Integrative SpO2 Probe ¦Double working modes, monitoring function and 24 hours ambulatory NIBP measure function can be flexibly set ¦NIBP and SpO2 can be monitored for a long time ¦NIBP and SpO2 data record for large capacity ¦With friendly user interface, the user can see list menu and review measure results ¦The device can display low power information, alarm information, error information and time information richly ¦Parameter alarm function is optional ¦Patient information can be flexibly set ¦Case management function.

PC software can achieve data review, analysis measure results, seeing trend, printing reports and other functions
Performance ¦NIBP Measure Method: Oscillometry
Measure Mode: The upper arm measure
Measure range:
ADULT:
SYS: 40mm
Hg~270mm
Hg MAP: 20mm
Hg~235mm
Hg DIA: 10mm
Hg~215mm
Hg PEDIATRIC:
SYS: 40mm
Hg~200mm
Hg MAP: 20mm
Hg~165mm
Hg DIA: 10mm
Hg~150mm
Hg NEONATAL:
SYS: 40mm
Hg~135mm
Hg MAP: 20mm
Hg~110mm
Hg DIA: 10mm
Hg~100mm
Hg Automatic measure
Interval: 5, 10, 15, 20, 30, 45, 60, 90, 120 minutes
Resolution: 1mm
Hg Accuracy: ±3mm
Hg Increasing pressure mode: force pump increases pressure automatically
Reducing pressure mode: self-motion ladder reducing pressure mode
Alarm parameter: SYS / MAP /
DIA ¦SPO2 Measure range: 0%~100%
(Resolution: 1%)
Accuracy: 70-100%, ±2%, below 70% unspecified Error in Weak
Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4 %. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
¦Pulse Rate Measuring range: 0bpm~250bpm
Resolution: 1bpm
Accuracy: ±2 bpm or ±2% (select larger)
¦Display: 2.4" TFT colour
LCD ¦Power: DC 3V(Two "AA", 1.5V
Alkali Battery) ¦Product safety type: Type BF applied part (Internally powered, defibrillation-proof) Physics speciality
Dimension: 128mm*69mm*36 mm (No including Packing)
Weight: <350g (Including Batteries) Accessories ¦Cuff for adult ¦Cuff for child ¦Large adult cuff ¦Integrative SpO2 Probe ¦USB data line ¦Disk (PC software) ¦Pack ¦User manual