CyberPower RMCARD205 Remote Management Card - Black
- Supported Protocols: TCP/IP, UDP, FTP, SCP, DHCP, DNS, SSH, Telnet, HTTP/HTTPS, SNMPv1/v3, IPv4/v6, NTP, SMTP, and Syslog
- Remote management: Web browser, CLI, SNMP or NMS
- Auto shutdown: Workstations, multiple servers
- Auto shutdown clients: 50
- Auto event notification: Email, SMS, SNMP Traps, Syslog
- Remote scheduling: Shutdown, startup, reboot
- Ethernet speeds: 10/100 Mbps
- Environmental Sensor compatible: Yes
- Upgradable firmware: Yes, via FTP or SCP
Any questions? Ask CelesteSM will help you find out quickly.
CyberPower RMCARD205
- Supported protocols: TCP/IP, UDP, FTP, DHCP, DNS, SSH, Telnet, HTTP/HTTPS, SNMPv1/v3, IPv4/v6, NTP, SMTP and Syslog
- Remote management: web browser, CLI, SNMP or NMS
- Auto shutdown: workstations and multiple servers
- Auto shutdown clients: 50
- Auto event notification: email, SMS, SNMP Traps and Syslog
- Remote scheduling: shutdown, startup and reboot
- Ethernet speeds: 10/100Mbps
- Environmental-sensor compatibility: Yes
- Upgradable firmware: Yes
- Warranty: 3 years
Being a full-featured network-management card, the CyberPower RMCARD205 remotely manages, monitors and controls select CyberPower UPS systems and ATS PDUs via a standard web browser, command line interface (CLI), simple network management protocol (SNMP) or network management system (NMS). Especially suited to handle enterprise installations, the RMCARD205 provides scheduling for UPS shutdown, startup and rebooting, along with event-action settings, event logging, status recording and automatic event notifications via email, SMS, SNMP traps, or Syslog. PowerPanel® Business Edition Client software protects servers and workstations from data loss due to power failure by initiating auto-shutdown command from a UPS when a power-loss event occurs.
An optional environmental sensor (ENVIROSENSOR) can be connected to the RMCARD205 to monitor the ambient temperature and humidity of a server room, IT closet or other critical environments. Administrators define temperature parameters in Fahrenheit or Celsius and thresholds can be configured to prompt the RMCARD205 to send a predefined notifications. The RMCARD205 comes with a three-year warranty.
The optional ENVIROSENSOR connects to the Universal port on the RMCARD205 to monitor ambient temperature and humidity. Notifications are enabled by default and alert thresholds can be easily customized to fit environmental-control requirements.
Allows administrators to control and configure the UPS without being onsite via a standard web browser, command line interface (CLI) or network management system (NMS).
In conjunction with the PowerPanel Business Edition Client, you can protect servers and workstations from data loss due to power failure.
Lets administrators conduct scheduled times for UPS and ATS PDU shutdown, startup and reboot. Functionality includes event-action management, event logging, and automatic event notification.
Provides immediate updates about power events via email, SMS, SNMP traps or Syslog server.
Traces the UPS and ATS PDU operational history, tracking events and input/output power-status records.
Allows administrators to customize UPS actions in response to power and system events.
Keep the RMCARD205 up to date with the latest firmware version. New firmware releases include new functionality, feature enhancements and bug fixes.
Maintain UPS firmware that manages features and keeps functions up-to-date. The UPS firmware upgrade is easy to complete via the web-management interface.
Covers defects in materials and workmanship in the product under normal use and conditions within three years of the purchase date. See warranty for details.
*Select UPS models only. Please contact your CyberPower Systems representative for information.
- CyberPower Remote Management Card
- RJ45/DB9 Serial Port Connection Cable
- Quick-Start Guide
- Spare Jumper
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Limited Warranty period (parts): 3 years
- Limited Warranty period (labor): 3 years
- Read full details
Return Policies
- Contact Manufacturer for Assistance
- This item is covered by Newegg.com's Manufacturer Warranty Only Return Policy.
- Read full return policy for details.
Manufacturer Contact Info
- Manufacturer Product Page
- Manufacturer Website
- Support Phone: 1-877-297-6937
- Support Website
- View other products from CyberPower
The CyberPower RMCARD205 is a network management card for monitoring and remotely controlling compatible CyberPower UPS systems and ATS PDUs. It suits IT administrators who need browser, CLI, SNMP, or NMS access, event notifications, and remote power scheduling.
Recommended For
- IT administrators managing a compatible CyberPower UPS in an unattended server room or network closet who need browser, SSH, or SNMP access without visiting the equipment.
- Small-business or homelab operators who need a compatible UPS to signal connected servers and workstations to shut down during a power event, helping protect data.
- Teams already using SNMP or a network management system that want UPS status, event logs, and power-event notifications integrated into their existing monitoring workflow.
- Facilities staff monitoring a compatible UPS in an IT closet or server room who want optional temperature and humidity alerts through CyberPower’s environmental sensor.
- Administrators responsible for multiple compatible CyberPower UPS units or ATS PDUs who need remote status checks and scheduled shutdown, startup, or reboot tasks.
Real-World Use Scenarios
- When a UPS protects an unattended server room or IT closet, an administrator can check its status over the network and receive alerts about power events without going to the site.
- In a small server environment, an administrator can pair the card with PowerPanel Business Edition Client so connected servers and workstations can shut down gracefully during a power failure, helping reduce the risk of data loss or corruption.
- For teams already using an SNMP monitoring system, the card can report UPS status and power events to that system, making it easier to track outages, load, and battery runtime alongside other infrastructure.
- When a site has a compatible UPS or ATS PDU that needs planned maintenance, an administrator can schedule a remote shutdown, startup, or reboot rather than relying on someone to operate it locally.
- In a server room where temperature or humidity needs monitoring, adding the optional environmental sensor lets administrators set thresholds and receive notifications when readings exceed them.
- When an administrator wants email alerts for UPS events, the card can send notifications through a configured email setup; a CyberPower-focused video demonstrates configuring email notifications for the RMCARD205.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | Remote monitoring and management of compatible CyberPower UPS systems and ATS PDUs, including coordinated shutdown of connected servers and workstations |
| Compatible Equipment | CyberPower Smart App Sinewave UPS systems, Smart App Intelligent LCD/AVR UPS systems, and ATS PDUs; CPS1500AVR is unsupported, as are UPS systems manufactured in or before 2010 with a ribbon cable at the RMCARD port |
| Remote Management And Networking | Manage and configure UPS and ATS PDUs through a web browser, CLI, SNMP, or NMS; 10/100 Mbps Ethernet connection |
| Supported Protocols | TCP/IP, UDP, FTP, SCP, DHCP, DNS, SSH, Telnet, HTTP/HTTPS, SNMPv1/v3, IPv4/IPv6, NTP, SMTP, and Syslog |
| Monitoring And Event Management | Real-time UPS monitoring, event notifications by email, SMS, SNMP traps, and Syslog, plus event and graphical power-condition logging |
| Shutdown And Scheduling | Can manage up to 50 PowerPanel Business Edition client servers and workstations, trigger shutdown during power events, and remotely schedule UPS shutdown, startup, and reboot |
| Security And Authentication | Supports SSL and TLS for secure email authentication, and RADIUS, LDAP, LDAPS, and Windows Active Directory for external authentication |
| Sensors And Firmware | Compatible with an optional ENVIROSENSOR; firmware is user-upgradable via FTP or SCP |
| System Requirements | Ethernet network connection and web browser; an SNMPv1/v3-compliant NMS is optional |
| Configuration And Installation | Hot-swappable; supports saving and restoring settings, configuring and updating multiple units at once, and managing multiple event-action settings |
| Dimensions And Included Components | Black card measuring 1.61 × 3 × 1.42 in; includes an RJ45/DB9 serial port connection cable, quick start guide, and spare jumper |
| Model Identifiers | CyberPower RMCARD205 remote management card |