Skip to main content
Out of stock
  • $7,573.99
  • This item is not returnable
Sold by Newegg

Shipped by Newegg

Price alert
Shop it at NeweggBusiness.

Eaton 9PX G2 6000VA 5400W 208/120V Online Double-Conversion UPS - L6-30P Input - 6x 5-20R - 1x L6-30R - 1x L14-30R - Cybersecure Network Card - Extended Run - 6U Rack/Tower - 9PX6KP1G2

  • 6U Rack/Tower
  • 3 Hour Recharge - 3 Minute Stand-by
  • 230 V AC Input - 240 V AC, 230 V AC, 220 V AC, 208 V AC, 200 V AC, 100 V AC, 110 V AC, 120 V AC Output
  • Single Phase - Pure Sine Wave
  • Serial Port - USB
  • LCD Display
  • 6 x NEMA 5-20R, 1 x NEMA L6-30R, 1 x NEMA L14-30R Receptacle(s)
  • Network-M3 Card, INDGW-M2 Card, Relay-MS Card
This item is covered under the Manufacturer Only Return Policy.
+
+
Overview
Specs
Reviews
See all Q & A

Any questions? Ask CelesteSM will help you find out quickly.

6kVA/5.4kW/120V/208V Battery Backup for Distributed IT and Edge Networks; Delivers Maximum Power Reliability with Best-in-Class Efficiency; Expandable Internal Battery Backup Keeps You Operational Through Power Outages
Humidity Range Operating:0-95% non-condensing
Max Operating Temperature:40 CELSIUS
Min Operating Temperature:0 CELSIUS
Voltage Output:120V; 208V; 240V; 200V; 220V; 230V
Power / Device Type:UPS
Power / Voltage Required:200V AC; 208V AC; 220V AC; 230V AC; 240V AC
Power Device / Form Factor:Rack-Mountable; Tower
UPS Technology:Online
  1. Power
Surge Suppression:Yes
Power Provided (VA):6000 VA
Power / Provided (W):5.4 KW
  1. Dimensions&Miscellaneous
Depth:27.000 Inch
Height:10.200 Inch
Width:17.300 Inch
Model:9PX6KP1G2
Weight:203 lbs.
  1. Connection
Output Connector(s):(6) 5-20R; (1) L6-30R; (1) L14-30R
Input Connector(s):NEMA L6-30P
Interfaces & Connections:NEMA L6-30P;(6) 5-20R; (1) L6-30R; (1) L14-30R
  1. Battery
Battery Type:Valve Regulated Lead Acid
Battery Technology:VRLA


Warranty & Returns

Warranty, Returns, And Additional Information

Return Policies

Manufacturer Contact Info

LOADING...

The Eaton 9PX6KP1G2 is a 6,000VA/5,400W online double-conversion UPS for businesses and IT teams protecting server, network, and other critical equipment; it includes a cybersecure Gigabit network card, maintenance-bypass distribution module, and rack/tower mounting hardware.

Recommended For

  • IT teams protecting rack servers, storage, and network equipment that need online double-conversion power conditioning and a safe-shutdown window during outages.
  • MSPs and infrastructure teams that need remote UPS monitoring and control, plus a maintenance bypass for servicing connected equipment.
  • Facilities with a suitable 200–240V supply that need to protect a substantial IT load and connect a mix of 120V and higher-voltage equipment.
  • Operators who need longer backup time and can add compatible external battery modules as their runtime needs grow.

Real-World Use Scenarios

  • A small server room or rack uses the UPS to ride through brief outages and give administrators time to save work or shut servers down cleanly; at heavier loads, the built-in battery is a short bridge, not long-duration backup.
  • An IT team protects a rack of servers, storage, and network equipment from power interruptions; the 6 kVA unit can serve as a shared rack-level backup when the connected load and power connections are within its limits.
  • A site with brief sags, surges, or line disturbances uses online double conversion to keep sensitive IT equipment supplied with conditioned power; the practical benefit is reducing exposure to incoming power fluctuations, not extending runtime during a prolonged outage.
  • A remote IT team monitors a protected rack over the network and configures supported servers for orderly shutdown when an outage lasts longer than the battery can cover; the included network card supports remote access, while shutdown behavior depends on compatible software and setup.
  • A rack containing both 120 V and 208 V equipment uses the included distribution module to connect compatible loads from one UPS; the maintenance-bypass feature can help keep loads supplied from utility power during UPS servicing when the installation is configured for bypass.

Spec Summary

AttributeValue
Best ForShort-term backup power for connected equipment, with a 6,000 VA / 5,400 W capacity and multiple outlet types
Capacity And Output6,000 VA / 5,400 W, with 50 Hz and 60 Hz output frequencies
Input And Output Voltage230 V AC input; selectable output voltages of 100, 110, 120, 200, 208, 220, 230, or 240 V AC
OutletsSix NEMA 5-20R, one NEMA L6-30R, and one NEMA L14-30R receptacle
Battery And Runtime180 V DC valve-regulated lead-acid battery system; runtime is 3 minutes at full load and 8.3 minutes at half load
Battery RechargeTypical recharge time is 3 hours
Dimensions And Weight10.2 in H × 17.3 in W × 27 in D; 203 lb
Included AccessoriesPowerPass distribution module with maintenance bypass, NETWORK-M3 Gigabit Network Card, USB and RS-232 cables, rack-mounting hardware, tower support stands, and quick start guide
Model IdentifiersEaton model 9PX6KP1G2; part number 9PX6KP1G2