Product Main Function
1. Test leakage initiating current of various kinds of leakage protector Range: 5~1000mA
2. Test leakage operating time Range: 0ms~999ms
3. Line AC voltage Range: 0~600V
4. Line voltage below AC 600V in relay protection switch testing below AC 250V
5. LCD 7-inch TFT color touch screen
6. Internal wiring diagram
ETCR8600 Leakage Protector Tester is designed to test the line AC voltage, leakage initiating current, residual non-operating current and leakage initiating separation time of various leakage protectors online, the test current from 5~1000mA with 16 grade (5, 10, 15, 20, 30, 40, 50, 60, 100, 150, 200, 250, 300, 500, 600, 1000mA), range of the leakage initiating separation time is 0~999ms, adopts 854X480 colorful touch LCD display, with battery power display, setting fault voltage indication, backlight brightness adjustment, internal wiring guidance diagram, convenient and direct-viewing, easy to operate. With high precision, small size, light weight, delicate appearance and easy to carry, the meter is an ideal tool for on-site or indoor detection of various leakage protectors.
Technical Parameters
Function Description
Power Supply 7.4V, rechargeable lithium battery (full about 8.4V)
Test Line Voltage Below AC 600V, in relay protection switch testing: below AC 250V
Rated Voltage AC 220V
Leakage Current Gears (5, 10, 15, 20, 30, 40, 50, 60, 100, 150, 200, 250, 300, 500, 600, 1000)mA
AC Voltage Gears 0~600V
Leakage Operating Time Range 0~999ms.
Leakage Operating Time Accuracy 5%rgt±3%dgt
Gears Current Accuracy ±10%rgt±5dgt
Gears Voltage Accuracy ±2rgt%±3dgt
Failure Information Indication LCD display “999” over time indication, it is possible that the rated initiating current grade of tested is too small or the leakage protector is faulty.
Test Wire Length 1.8M
Test Mode Manual or automatic
Display Mode LCD: 7 inches, TPT color touch screen
Meter Dimension 215mm×178mm×83mm
Battery Voltage When the battery voltage lower than 7.0V, low battery voltage symbol display, and remind to replace the battery. The measurement value is also accurate at this time
Working Current 365mA Max
Working Temperature -10oC-40oC, below 80%rh.
Storage Temperature -10oC-60oC, below 70%rh.
Insulation Strength 100MO, AC 2kV/rms (between the shell and the screw).
Suitable Safety Standard IEC1010-1, IEC1010-2-032, Pollution degree 2, CAT = 3 \* ROMAN III(600V) IEC61326 (EMC standard).
Host 1PCS
Meter Bag 1PCS
Charger 1PCS
Probe Test Wire 1PCS
Crocodile Clip Test Wire 1PCS
Socket Test Wire 1PCS
Package Box 1PCS
Manual 1PCS
Certificate 1PCS
Warranty Card 1PCS