ETCR9000S Portable H/L Voltage Clamp Current Meter Range AC 0.00mA~1200A
Notice:
The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.
At the same time, please forgive us that we are unable to provide the English user manual. If you need it, please contact the customer service after purchase.
Thanks for your support!
Product Main Function
Measuring H/L Voltage AC leakage curren, current,
Range:AC 0.00mA~1200A
Peak hold, Data Storage: 99 Groups
Line voltage: below 10kV
Clamp size: F48mm
ETCR9000S H/L Voltage Clamp Current Meter applicable to below 10kV H/L voltage leakage current and current measurement . Range: 0.00mA~1200A, jaw size is F48mm, special alloy for current clamp, magnetic shield technology, strong anti-interference ability, ensure measurement accuracy and stability . The instrument has functions such as peak hold, data retention, and data storage (group 99). It can also be used as a tester for high and low voltage ratios, that is to measure the high and low voltage currents of the primary and secondary circuits, respectively, and can be calculated by manual calculation. The ratio of high and low pressure.
The Meter is composed of a high voltage detector and 3pcs HV insulated rods. The insulation rod is light, with features such as moisture resistance, high temperature resistance, impact resistance, bending resistance, high insulation, and detachability.
Technical Parameters
Function Description
Power Supply DC 6V(1.5V x4)
Clamp F48mm
LCD 47mm×28.5mm(with backlight)
Range AC 0.00mA~1200A
Resolution 1mA
Accuracy ±1%rdg±3dgt(23?±5? , below 80%rh)
Data storage 99 set
Auto Power-off 15 minutes off automatically
Working environment -10? ~ 40? , below 80%rh
Store environment -10? ~60? , below 70%rh
Structure Drip-proof type
Measurement method Clamp CT, Non-contact measurement, Points method
Frequency 50Hz, 60Hz Automatic Identification
Shift Automatic shifting
Peak Hold Automatically hold the test value at a high point. Press and hold the PEAK button in the test mode until the PEAK lamp lights up. The peak hold function is enabled.
Data Hold Press HOLD key to hold data in test mode, “HOLD” symbol display
Data review "MR" symbol indicates that you can flip through the stored data
Overflow display Overrange overflow function: "OLA" symbol display
Line voltage Bare lead test below 1kV, current insulation test for safety insulation under 10kV (with insulated handle operation)
Measure time 0.5 seconds/time
Voltage alarm When battery voltage decreases to about 4.8V, battery voltage low icon will display
Insulation rod 900 mm
Insulation AC 220kV/rms(Insulated handle and detector housing)
Weight Meter: 550g, about 2Kg
Dimension 255mm×76mm×31mm
Package outer packing Carton
inner packing Cloth bag
Accessory Meter 1 PCS
insulation rod 1 PCS
Cloth bag 1 PCS
Manual 1 PCS
Certificate 1 PCS
Warranty Card 1 PCS