Weather Alert: Severe winter storms may impact delivery times in some regions. We appreciate your patience as carriers work to deliver orders as quickly as possible. UPS Service Alerts.
  • $518.69
  • Free 30-day Returns
  • Ships from Hong Kong.
    Price alert
    Sold by FeiPengLin

    Shipped by FeiPengLin

    Shop it at NeweggBusiness.

    Meet Your Seller

    ETCR9600 LV Transducer Transformation Ratio Tester Data Storage 3000 Groups

    • ETCR9600 LV Transducer Transformation Ratio Tester Data Storage 3000 Groups
    +
    +
    Overview
    Specs
    Reviews
    avatar

    Any questions? Our AI beta will help you find out quickly.

    ETCR9600 LV Transducer Transformation Ratio Tester Data Storage 3000 Groups
    Notice:
      The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.
    At the same time, please forgive us that we are unable to provide the English user manual. If you need it, please contact the customer service after purchase.
    Thanks for your support!
    Reference Condition
    Influence Quantity Base Condition Working Condition
    Environment Terperature 23?±5? -15?~50?
    Environment Humidity 40%~60% <80%
    Sine Wave Distortion =1% =3%
    Signal Frequency 50HZ±5HZ 45HZ~65HZ
    Angel Error Test Primary Current Clamp 60A±1A 0.0A±800A
    Secondary Current Clamp 1A±0.2A 10mA~5A
    External Electric & magnetic Field Should avoid
    The tested wire position The tested wire is at the center of the clamp
    Technical Parameter
    Function Description
     Fuction  Current, transformation ratio, ratio error, angle error test, phase and polarity adjustment of the low voltage primary and secondary circuit of the current transducer
     Primary Current Clamp Test Accuracy   Range:0.0A~800A;Resolution:0.1A; Accuracy:±0.5%FS( 23?±3?,below 70% RH,the detected conductor is in the center position of the clamp);
     Secondary Current Clamp Test Accuracy  Range:0.00mA~5A;Resolution:0.01mA;Accuracy:±0.5%FS
     Transformation Ratio Measurement Range  1~500
     Transformation Ratio Resolution  0.1
     Angle Error Test Accuracy  Range:0~360°;Accuracy:±3°
     Automatic Shut Down  15 minutes after boot up, the meter shuts down automatically without any operation
     Battery Specification  Alkaline batteries (1.5V AAA × 4)
     Battery Voltage  When battery voltage is lower than 4.8V, low battery voltage symbol  will display and remind to replace battery. 
     Overflow Display  Exceed measure range overflow function: “OLA” symbol display
     Sampling Rate  3 times/second
     Data Storage  3000 groups
     Primary Current  Clamp Size  Jaw Size:f80mm×80mm; Out Shape Size: 76mm×255mm×31mm
     Secondary Current Clamp Size  Jaw Size: f8mm; Out Shape Size: 137mm×40mm×19.5mm
     Host Dimension  75mm×170mm×30mm
     Current Clamp Cable Length  2M
     Instrument Weight  1000g
     Insulation Strength  AC3700V/rms between the core and shell
     Host  1 PCS
     Primary Current Clamp  1 PCS
     Secondary Current Clamp  1 PCS
     Tool bag  1 PCS
     Manual  1 PCS
     Certificate  1 PCS
     Warranty Card  1 PCS

    Warranty & Returns

    Warranty, Returns, And Additional Information

    Warranty

    • Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
    • CONTACT

    Return Policies

    • Return for refund within: 30 days
    • Return for replacement within: non-replaceable
    • This item is covered by FeiPengLin Return Policy

    Manufacturer Contact Info

    LOADING...