Your Browsing History
Vertiv Liebert GXT5-500LVRT2UXLN Vertiv Liebert GXT5 500VA 120V UPS with SNMP/Webcard - 2U Rack/Tower - 3 Hour Recharge - 15 Minute Stand-by - 120 V AC Input - 120 V AC Output - 6 x NEMA 5-15R
- Application/Usage Mission Critical Equipment
- Emergency Power OFF Yes
- Plug/Connector Type NEMA 5-15P
- Cord Length 10 ft
- Phase Single Phase
- Receptacle Type NEMA 5-15R
- Transfer Time 0 ns
- Receptacle Detail 6 x NEMA 5-15R
- Circuit Breaker Yes
- Input Voltage 120 V AC
- Output Voltage 120 V AC
- Input Current 6 A
- Waveform Type Pure Sine Wave
- Output Current 4.20 A
- Input Voltage Range 110 V AC - 125 V AC
- Input Frequency 60 Hz
- Load Capacity (VA) 500 VA
- Load Capacity (Watt) 500 W
- Battery Life 5 Year
- Battery Chemistry Lead Acid
- Hot Swappable Yes
- Battery Size 12V
- Hot Pluggable Yes
- Number of Batteries 3
- Backup/Run Time (Half Load) 36.50 Minute
- Backup/Run Time (Full Load) 15 Minute
- Battery Characteristics Valve-regulated, Non-spillable
- DC System Voltage 12 V DC
- Typical Battery Recharge Time 3 Hour
- USB Yes
- VGA No
- Network (RJ-45) Yes
- Modem (RJ-11) No
- Serial Port Yes
- Maximum Operating Temperature 104°F (40°C)
- Country of Origin China
- TAA Compliant No
- Energy Star Yes
+
+
Overview
Specs
Reviews
See all Q & A
Any questions? Ask CelesteSM will help you find out quickly.
Try me now
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Limited Warranty period (parts): 1 year
- Limited Warranty period (labor): 1 year
- Read full details
Return Policies
- Contact Manufacturer for Assistance
- This item is covered by Newegg.com's Manufacturer Warranty Only Return Policy.
- Read full return policy for details.
Manufacturer Contact Info
LOADING...
The Vertiv Liebert GXT5-500LVRT2UXLN is a 500VA/500W, 2U rack/tower UPS with six NEMA 5-15R outlets, pure sine wave output, and a network card; it suits IT and other mission-critical equipment that needs backup power and network monitoring.
Recommended For
- Small server, NAS, and network-rack operators who need online double-conversion backup and power conditioning for a modest 120V equipment load.
- Homelab and small-office admins who want a UPS that can support graceful shutdown of a server or NAS during an outage, with USB and network-card monitoring options.
- IT teams outfitting a compact rack or tower setup that needs six standard 120V NEMA 5-15R outlets and a 2U UPS form factor.
- Operators of unattended or remote IT equipment who want to monitor UPS status over a network using a compatible IntelliSlot network card.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | Equipment needing 500 VA/500 W backup power, with six outlets and rack/tower installation |
| Capacity And Output | 500 VA / 500 W capacity; configurable 110/115/120/125 V AC output with ±3% regulation |
| Input And Power Connection | 60–150 V input range, 40–70 Hz auto-sensing, single NEMA 5-15P input connection |
| Outlets And Connectivity | Six NEMA 5-15R outlets; network card included, with network (RJ-45) and serial connectivity |
| Battery And Runtime | Valve-regulated lead-acid battery; runtime is 40.4 minutes at half load and 17.9 minutes at full load |
| Form Factor And Dimensions | Rack/tower form factor; 3.4 × 16.9 × 15.7 in |
| Weight | 37 lb |
| Operating Environment | Operating temperature: 32°F–104°F (0°–40°C); storage temperature: −4°F–140°F (−20°–60°C); humidity: 0%–95%, non-condensing |
| Safety And Compliance | UL 1778 4th Edition and CSA 22.2 No. 107.3 |
| Model Identifiers | Vertiv Liebert GXT5-500LVRT2UXLN; 120 V international version |