Features
High voltage output acousto-optic warning
Switch gear error warning
Automatic release measured line capacitance power
Insulation resistance test current accords with IEC348 standard requirement
Large LCD display: the word 22mm, the maximum display number 1999
Insulation resistance measurement level output voltage: 250V, 500V, 1000V
Insulation resistance measuring range: 0 - 2000M
DC voltage measurement range: 0 - 1000V
The measuring range of AC voltage: 0 - 750V
Data retention
Insulation resistance manual, locking, timing measurement
Specification
Instrument should specify the annual cycle, at 18 C ~ 28 C, relative humidity less than 75% under the conditions of re-calibrated.
Summary
Measuring between the earth and the end of the maximum allowed voltage: 1000V DC or AC
Work mode: Dual-slope integration A / D converter
Sampling time: about 0.4 seconds / second.
Display: LCD display, character height 22mm.
Maximum display: 1999 (ie, three and a half).
Polarity Indication: '-' indicates negative.
Over-range display: '1 'or' -1 '.
Unit display: a battery units.
Power Supply: 1.5V × 6 (AA) batteries (alkaline or recommend the use of high-energy batteries).
Power consumption: 5mA (DC1000V, AC750V, 200, )
About 30mA (200M/250V)
About 50mA (200M/500V)
Approximately 100mA (2000M/1000V)
Battery voltage indication: LCD display symbols.
Operating temperature: 0 C ~ 40 C
Humidity: less than 85% RH
Storage temperature: -10 C ~ 50 C
Size: 192 × 122 × 55mm
Weight: about 545g
Note: Batteries are not included in the package
Attachment
1 X Table pen rating: 1000V 5A
1 X Test folder level: 1000V 5A
1 X a Instructions
1 X Bag