it can automatically turn off the power after 10 minutes, If you forget to turn off the power when you are not using it. Compactness-durability and portability.
The transmitter is integrated with the function of AC/DC voltmeter, which
can measure: 12 to 400V AC/DC voltage on a linear basis:
AC: 12 ~ 400V (50 to 60 Hz) ± 2.5 %.
DC: 12~400V ± 2.5 %
Applications: Installation and maintenance of weak current system, communication line, comprehensive wiring circuit, telephone system, computer network, other metal wire circuit etc.
Technical parameters of transmitter
Output signal 125kHz
External voltage DC 12~400V ± 2.5 %;
identification range AC 12~400V(50~60Hz) ± 2.5 %
Display LCD, with function display and column chart
External voltage Max. 400V AC/DC
dielectric strength CAT III 300V
Overvoltage type 2
Power supply 3.7V 1400 mAh Lithium battary
MIN curren 80mA
MAX curren 300mA
Fuse 0°C ~ 40 °C, with maximum relative humidity
In work of 80% (non-condensation)
In storage -20°C ~ 60°C, with maximum relative humidity of
Altitude 80% (non-condensation) Max. 2000m
Dimensions (HxW*D) 156 x 80 x32 mm
Weight 235g with battary
Technical parameters of receiver
Depth of tracking The depth of tracking depends on the material and specific applications
Single pole application About 0~1m
Dual-pole application About 0- 0.5 m
Single loop line Up to 2.5 m
Grid voltage identification About 0~ 0.4 m
Display LCD, with function display and column chart
Power supply 3.7V 1400 mAh Lithium battary
MIN current 100mA
MAX current 300mA
In work 0°C ~ 40°C, with maximum relative humidity of 80% (non-condensation)
In storage -20°C ~ +60°C, with maximum relative humidity of 80% (non-condensation)
Altitude Max. 2000m
Dimensions (HxWxD) 226 x 73 x29 mm
Weight 235g with battary