PINTECH High Frequency Differential Probes for Oscilloscope 800V, 150MHZ 20X/200X Attenuation Rate, Oscilloscope Probe with Standard BNC Interface, PT-5108
- Rise Time: 2.3ns. This differential probe measures signals with very fast rise times.
- DC-150MHz, Accuracy (Typical):±2%, Attenuation Ratio: 20X/200X.
- Maximum differential test voltage : 800Vp-p.
- Widely Used: The oscilloscope probe features BNC interface, compatible with all oscilloscopes.
- Package Included: PT-5108 differential probe x 1, Adapter x 1, Probe Hook x 2, Alligator Clip x 2, BNC cable x 1, Dedicated Input Cable x 1, Manual x 1. PINTECH offers 1 Year warranty, you can contact us if you have any questions!
Any questions? Ask CelesteSM will help you find out quickly.
MODEL: PT-5108
Bandwidth (-3dB): DC-150MHz
Testing Voltage(Vp-p): 20X:80V; 200X: 800V
Input DC Voltage: 20X:40V; 200X: 400V
Attenuation Rate: 20X/200X
Rising Time: 2.3ns
Accuracy: ±2%
Input Impedance: Between the two ends: 20M//5pF, Single-ended to ground: 10M//10pF
Common-mode voltage: 280V
CMRR: 60Hz:>80dB; 100Hz:>60dB; 1MHz:>50dB
Oscilloscope Input Impedance: 50M
Noise: 1mV rms
Weight: 450g/0.99lb
Dimension(LxWxH): 220x85x30 mm
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: 30 days
- This item is covered by GUANGZHOU PINTECH CO LTD Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory
The PINTECH PT-5108 is a high-frequency differential oscilloscope probe designed for engineers, technicians, and lab users who need to measure floating or differential signals up to 800Vp-p with 150MHz bandwidth and 20X/200X attenuation through a standard BNC oscilloscope connection.
Recommended For
- Engineers debugging offline power supplies, PFC stages, inverters, or half-bridge nodes who need to view floating high-side waveforms on a standard BNC oscilloscope. Differential probes are commonly positioned for mains-referenced and line-to-line measurements where grounded passive probes are a mismatch, and community discussions frequently mention half-bridge sensing as a primary use case.
- Bench technicians and electronics labs that already use general-purpose oscilloscopes and want a dedicated differential probe instead of tying up two channels with A-B math. Community discussions repeatedly describe differential probes as the cleaner option when two passive probes do not provide enough accuracy or convenience.
- Users measuring fast switching edges in power electronics who need more bandwidth than entry-level high-voltage probes typically offer. The PT-5108 is positioned as a 150 MHz differential probe with 2.3 ns rise time, which fits tasks like observing switching transitions, gate-related waveforms, and ripple/noise on floating nodes rather than only low-frequency mains checks.
- Repair and validation workflows on mains-powered equipment where safety and proper reference isolation matter more than maximum channel count. Professional guidance consistently recommends high-voltage differential probes for floating primary-side measurements instead of standard grounded probes.
Real-World Use Scenarios
- Checking switching-node or gate-drive waveforms in offline SMPS and inverter circuits: users connect the probe across two non-ground-referenced points to see the real differential waveform without ground-clipping one side, and the typical result is safer, clearer debugging of ringing, duty-cycle behavior, and switching transitions than with a standard single-ended probe.
- Measuring line-to-line outputs on motor drives or VFD-style power stages: the practical use is comparing two high-side phases that a bench scope cannot safely reference to earth ground, and the likely outcome is that engineers can verify PWM shape, switching symmetry, and noise problems without shorting a phase to scope ground.
- Looking at fast edges in half-bridge, MOSFET, or IGBT designs during development: in real bench work the probe is used to capture high-side transitions and overshoot that are hard to trust with improvised two-channel subtraction, and the usual experience is more stable waveform viewing with enough bandwidth to spot ringing and timing issues.
- Debugging mains-referenced sections of power electronics prototypes: users rely on a differential probe when they need to inspect bridge rectifier outputs, primary-side controller signals, or floating shunts, and the expected outcome is practical access to measurements that would be risky or misleading with a normal grounded probe.
- Upgrading a standard BNC oscilloscope for differential measurements in lab or repair work: buyers typically use this type of probe when their scope lacks isolated inputs, and the real-world result is that an ordinary bench scope becomes usable for floating-voltage troubleshooting as long as the waveform stays within the probe's attenuation and voltage limits.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | Measuring differential signals up to 800 Vp-p and frequencies to 150 MHz; suitable for oscilloscope diagnostics, signal verification, and mid‑band high-frequency work where a differential probe with BNC output is required |
| Electrical Performance | DC to 150 MHz bandwidth with 2.3 ns rise time and typical accuracy ±2%, rated for differential test voltages up to 800 Vp-p |
| Attenuation And Input | Differential probe offering 20X and 200X attenuation rates with a standard BNC interface for connection to oscilloscope inputs |
| Compatibility And Interface | Standard BNC output; described as compatible with oscilloscopes (fits oscilloscopes that accept BNC‑connected differential probes) |
| Physical And Packaging | Probe body 220 × 85 × 30 mm; package includes PT-5108 probe, adapter, 2 probe hooks, 2 alligator clips, BNC cable, dedicated input cable, and manual |
| Standards And Warranty | CE certified and covered by a 1 year warranty |
| Model Identifiers | PINTECH PT-5108 differential oscilloscope probe, sold per each unit |
Reference Q&A
Q: Should I choose the PINTECH PT-5108 or a 50 MHz, 800 V differential probe?
A: Choose the PT-5108 when you need more bandwidth for faster switching edges, gate-drive waveforms, and higher-frequency power electronics work. Its published spec is DC to 150 MHz with 2.3 ns rise time, 20X/200X attenuation, and up to 800 Vp-p differential input, so it fits users who want more waveform detail than a 50 MHz probe usually shows. A 50 MHz alternative is the better fit when your measurements are slower and you want to prioritize simpler lower-bandwidth use over extra headroom. This is mainly a bandwidth trade-off rather than a voltage-range decision.
Q: Is the PT-5108 a better choice than a standard passive BNC probe for oscilloscope voltage measurements?
A: Choose the PT-5108 when you need to measure floating or high-side signals safely as a true differential measurement. Community guidance consistently treats differential probes as the right tool for mains-level, half-bridge, and non-ground-referenced measurements because standard passive probes reference the oscilloscope ground and are not the same tool for that job. A passive BNC probe is still the better choice for routine ground-referenced measurements because it is simpler and typically enough for low-voltage single-ended signals.
Q: Should I buy the PT-5108 or move up to a higher-voltage differential probe?
A: Choose the PT-5108 if your real requirement stays within its 800 Vp-p differential range and you want a moderate-bandwidth BNC differential probe. Move up to a higher-voltage model if you regularly test higher-energy power stages, inverter outputs, or applications that need more voltage margin. Official product lines from Tektronix, Siglent, and Micsig show that higher-tier differential probes usually increase maximum voltage first, and often add bandwidth or vendor-specific scope integration as well. The trade-off is that higher-voltage models are typically aimed at more demanding benches rather than basic 800 Vp-p work.
Q: PT-5108 vs a premium brand differential probe: which is the better fit?
A: Choose the PT-5108 when you want core differential-probe capability in a standard BNC form factor and your needs match its published 150 MHz and 800 Vp-p envelope. Move to a premium-brand probe when you specifically need broader voltage ranges, tighter integration with a matching oscilloscope platform, or access to higher-end probe families with more specialized options. Official product catalogs from Tektronix and Siglent show that premium lines often add deeper ecosystem integration and a wider range of performance tiers, while the PT-5108 stays focused on general-purpose standalone compatibility.
Q: Who is the PT-5108 most suitable for?
A: The PT-5108 is best suited for users who need to measure floating or high-side differential signals on a standard BNC oscilloscope, especially in power electronics, motor drives, converters, and similar high-voltage bench work. Its 150 MHz bandwidth, 20X/200X attenuation options, and 800 Vp-p maximum differential voltage make it more appropriate for engineering diagnostics than for basic hobby probing.
Q: Will the PT-5108 work with my oscilloscope?
A: Usually yes, if your oscilloscope accepts a standard BNC input and you can manually account for the probe attenuation. The PT-5108 is described as using a standard BNC interface and being compatible with all oscilloscopes, but buyers should still confirm their scope's input expectations, usable bandwidth, and attenuation setup method. As with comparable probes, matching probe bandwidth to the oscilloscope is important for getting the advertised performance.
Q: Is 150 MHz enough, or should I buy a higher-bandwidth differential probe?
A: 150 MHz is enough for many power supply, inverter, switching, and general high-voltage troubleshooting tasks, but it is not the best choice for very fast serial buses or advanced high-speed edge analysis. If your oscilloscope and signals are substantially faster, a higher-bandwidth probe will preserve more waveform detail. For typical bench measurements where safety and differential measurement matter more than extreme speed, 150 MHz is a practical middle-ground.
Q: What is the main trade-off of the PT-5108 versus a lower-voltage or lower-end differential probe?
A: The main benefit of the PT-5108 is broader usefulness for higher-voltage differential measurements, thanks to its 800 Vp-p rating and switchable 20X/200X attenuation. The trade-off is that differential probes are generally more specialized and more complex to use than basic passive probes, and higher attenuation can make very small signals less convenient to inspect. It is a better fit for safety-critical floating measurements than for everyday low-voltage probing.
Q: Is the PT-5108 a good choice for portable or field use?
A: It can work for portable use, but it is better thought of as a bench measurement accessory than a travel-friendly tool. Differential probes add setup complexity compared with a standard passive probe, and comparable models often rely on external power or batteries. If your priority is safe differential measurement on-site, it can be useful; if your priority is the simplest grab-and-go probe, a basic passive probe is easier.
Q: Who is this differential probe suitable for?
A: This probe is best suited for users who need to measure floating or non-ground-referenced signals on a standard BNC oscilloscope, especially in power electronics, mains-related circuits, or other higher-voltage differential measurements. It is less suitable if your work is mostly low-level, precision small-signal measurement, where attenuation and probe noise can make weak signals harder to see.
Q: Is this a good choice if I already have a regular oscilloscope with standard probes?
A: Yes, if your main need is safe differential measurement on a grounded oscilloscope. A differential probe solves problems that standard passive probes do not, such as measuring voltage between two non-ground points without tying one side to scope ground. The trade-off is extra cost and lower sensitivity than a direct low-voltage probe setup.
Q: Can this probe still be useful for lower-voltage measurements?
A: Yes, but it is not ideal for very small signals. Based on the product data, the PT-5108 uses 20X and 200X attenuation, so the measured signal is reduced before it reaches the oscilloscope. That is usually fine for tens of volts, but it becomes a disadvantage when measuring very low-amplitude signals because the displayed waveform will be smaller and may be harder to read cleanly.
Q: What are the main trade-offs of choosing this probe?
A: The main advantage is safer and more correct differential measurement on a standard grounded oscilloscope. The main trade-offs are attenuation, which reduces small-signal visibility, and a 150 MHz bandwidth limit, which may not be enough for very fast or higher-frequency work. It is a practical fit for general high-voltage differential troubleshooting, but not the best fit for the most demanding high-speed or low-level precision measurements.