Skip to main content
  • $85.99
  • Free 30-day Returns
  • Price alert
    Shop it at NeweggBusiness.

    9999 Counts 1000A AC/DC Digital Clamp Multimeter with Color Screen

    • Ultimate Safety for Professional Use: Neoteck digital clamp meter boasts a CAT III 1000V / CAT IV 600V safety rating, delivering superior protection against high-voltage transients. It offers electricians and HVAC technicians maximum safety and compliance when troubleshooting main power supplies, industrial panels, and heavy machinery
    • True-RMS & LoZ & VFD & Inrush Current Mode for Modern Systems: Engineered with True-RMS technology and VFD mode, this clamp multimeter accurately measures complex waveforms from variable-frequency drives and non-linear loads. It also features inrush current measurement and LoZ mode to prevent ghost voltage, ensuring precise diagnostics for motor-driven systems and industrial equipment
    • All-in-One Electrical Diagnostics: This clamp meter multimeter offers comprehensive testing: 1000A AC/DC current, 750V AC voltage, 1000V DC voltage, temperature, capacitance, inductance, and NCV. Its 40mm jaw handles thick cables, making it ideal for industrial, automotive, and HVAC applications
    • High-Readability Color Display with Analog Bar: Featuring a 9999-count color screen and real-time analog bar, this digital clamp multimeter ensures clear visibility of measurements and trends, even in low light. It supports efficient diagnostics in panels, crawl spaces, or bright environments
    +
    +
    Overview
    Specs
    Reviews
    avatar

    Any questions? Our AI mode will help you find out quickly.

    Professional Clamp Multimeter with True RMS for Electricians & HVAC Techs

    clamp meter

    Neoteck clamp multimeter is designed for electricians, HVAC technicians, and industrial maintenance crews, ideal for troubleshooting motor drives, electrical panels, and distribution systems. Clamp meter ensures safe, accurate measurements in commercial, residential, and industrial settings.

    Reasons for Inaccurate Current Measurement

    Both wires clamped together If you clamp both the live and neutral wires, their currents cancel out, giving a near-zero reading. Always clamp only one wire.
    Wire not centered The wire should be placed in the middle of the clamp opening. Off-center placement reduces accuracy.
    Clamp not fully closed Dirt or a loose hinge can cause a gap, giving weak readings. Close the clamp tightly. If you hear a noise, open and close it again. If the noise stays, clean the dirty surfaces.
    Wrong range selected If the manual range is set too high (e.g., 200A for a 0.5A current), the reading may appear very low or inaccurate. Use auto-range or select a lower range.
    Current is too small Some clamp meters have poor resolution at low currents (e.g., below 0.1A). Try wrapping the wire around the clamp several times and divide the reading by the number of wraps.
    Low battery A weak battery can cause erratic or incorrect readings. Replace the battery if needed.
    Nearby conductors cause error Strong magnetic fields from other current-carrying wires near the clamp can affect accuracy. Try to isolate the wire being measured.

    Portable Clamp Meter Kit with Test Leads, Case & User Manual

    clamp meter multimeter

    Get everything you need in one kit. This clamp multimeter comes with test leads, a user manual, and a convenient storage case. Its compact, rugged design makes this amp clamp multimeter easy to carry to any job site, ensuring you're always prepared for electrical testing and troubleshooting tasks.

    • Estimate current first. If you are not sure, start with the highest range, then switch to a lower range for a more accurate reading. Never measure large current on a small range – it can damage the meter.

    • Clamp only one wire – Never clamp both live and neutral together, or their currents will cancel out and the reading will be zero.

    • Because that "single wire" might still contain both live and neutral inside (like a power cord). Their currents cancel out. To get a reading, you must clamp onto one of the phase wires.

    • If the current is too small for your clamp meter, try this trick:Wrap the same wire around the clamp several times (e.g., 5 or 10 turns).Then divide the reading on the display by the number of turns.

    • Voltage is not measured with the clamp. You must use the test leads (red and black probes).

    Neoteck Clamp Meter Series for Home, Industrial, Laboratories, Factories, etc..

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/c9f10072-ac2e-48ce-8e4e-2d447d385390.__AC_SR200,225___.jpg

    9999 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/202d562f-b077-4a08-8b65-68db1da5704f.__AC_SR200,225___.jpg

    6000 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/31517678-ddc6-4704-ad80-c53359d6ddf9.__AC_SR200,225___.jpg

    4000 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/073bce5d-4e63-4209-86d4-b08258b3101d.__AC_SR200,225___.jpg

    6000 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/2795bad8-fc4a-4136-8e4e-466747537d30.__CR0,0,200,225_PT0_SX200_V1___.png

    2000 Counts Multimeter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/7add195c-9530-4c34-a3bf-5ffa2c2ebf32.__AC_SR200,225___.jpg

    6000 Counts Multimeter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/15c437ef-eaf6-4f6c-be4c-b4091dd997d7.__CR0,0,200,225_PT0_SX200_V1___.jpg

    Pen Type Multimeter

    Customer Reviews
    Price
    Security Level
    CAT III 1000V CAT III 600V CAT III 600V CAT III 600V CAT III 1000V CAT III 600V CAT II 600V
    AC Current
    100A/600A/1000A 6A/60A/800A 1A/40A/600A 6A/60A/800A 200uA/2000uA/20mA/200mA/10A 600uA/6000uA/60mA/600mA/6A/10A -
    DC Current
    100A/600A/1000A - - 6A/60A/800A 200uA/2000uA/20mA/200mA/10A 600uA/6000uA/60mA/600mA/6A/10A -
    AC Voltage
    1V/10V/100V/750V 600mV/6V/60V/600V 4V/40V/400V/600V 600mV/6V/60V/600V 2V/20V/200V/600V 6V/60V/600V 10mV-600V
    DC Voltage
    1V/10V/100V/1000V 600mV/6V/60V/600V 400mV/4V/40V/400V/600V 600mV/6V/60V/600V 200mV/2V/20V/200V/600V 600mV/6V/60V/600V/600V 0.1mV-600V
    Capacitance
    10nF - 100mF(8 Ranges) 60nF-60mF(7 Ranges) 4nF - 40mF(7 Ranges) 60nF-60mF(7 Ranges) 4uF-2000uF 60nF - 60mF (7 Ranges) 10nF- 40mF
    Resistance/Frequency/DutyCycle
    Resistance/Frequency/DutyCycle Resistance/Frequency/DutyCycle Resistance Resistance/Frequency/DutyCycle Resistance/Frequency Resistance/Frequency Resistance/Frequency
    NCV/Continuity
    NCV/Continuity(=50O±30O) NCV/Continuity(=50O±10O) NCV/Continuity(=50O) NCV/Continuity(=50O±10O) Continuity NCV/Continuity NCV/Continuity
    Clamp Size
    40MM 26MM 26MM 26MM - - -
    Power Source
    2 x 4.5V AAA Battery(Included) 2 x 3V AAA Battery(Included) 2 x 3V AAA Battery(Included) 2 x 3V AAA Battery(Included) 1 x 9V Battery(Included) 2 x 1.5V AAA Battery(Included) 2 x 1.5V AAA Battery(Included)
    Range Selection
    Auto/Manual Auto/Manual Auto Auto/Manual Auto Auto/Manual Auto/Manual
    Temperature Detection
    ? ? ? ? ? ? ?

    Professional Clamp Multimeter with True RMS for Electricians & HVAC Techs

    clamp meter

    Neoteck clamp multimeter is designed for electricians, HVAC technicians, and industrial maintenance crews, ideal for troubleshooting motor drives, electrical panels, and distribution systems. Clamp meter ensures safe, accurate measurements in commercial, residential, and industrial settings.

    Reasons for Inaccurate Current Measurement

    Both wires clamped together If you clamp both the live and neutral wires, their currents cancel out, giving a near-zero reading. Always clamp only one wire.
    Wire not centered The wire should be placed in the middle of the clamp opening. Off-center placement reduces accuracy.
    Clamp not fully closed Dirt or a loose hinge can cause a gap, giving weak readings. Close the clamp tightly. If you hear a noise, open and close it again. If the noise stays, clean the dirty surfaces.
    Wrong range selected If the manual range is set too high (e.g., 200A for a 0.5A current), the reading may appear very low or inaccurate. Use auto-range or select a lower range.
    Current is too small Some clamp meters have poor resolution at low currents (e.g., below 0.1A). Try wrapping the wire around the clamp several times and divide the reading by the number of wraps.
    Low battery A weak battery can cause erratic or incorrect readings. Replace the battery if needed.
    Nearby conductors cause error Strong magnetic fields from other current-carrying wires near the clamp can affect accuracy. Try to isolate the wire being measured.

    Portable Clamp Meter Kit with Test Leads, Case & User Manual

    clamp meter multimeter

    Get everything you need in one kit. This clamp multimeter comes with test leads, a user manual, and a convenient storage case. Its compact, rugged design makes this amp clamp multimeter easy to carry to any job site, ensuring you're always prepared for electrical testing and troubleshooting tasks.

    • Estimate current first. If you are not sure, start with the highest range, then switch to a lower range for a more accurate reading. Never measure large current on a small range – it can damage the meter.

    • Clamp only one wire – Never clamp both live and neutral together, or their currents will cancel out and the reading will be zero.

    • Because that "single wire" might still contain both live and neutral inside (like a power cord). Their currents cancel out. To get a reading, you must clamp onto one of the phase wires.

    • If the current is too small for your clamp meter, try this trick:Wrap the same wire around the clamp several times (e.g., 5 or 10 turns).Then divide the reading on the display by the number of turns.

    • Voltage is not measured with the clamp. You must use the test leads (red and black probes).

    Neoteck Clamp Meter Series for Home, Industrial, Laboratories, Factories, etc..

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/c9f10072-ac2e-48ce-8e4e-2d447d385390.__AC_SR200,225___.jpg

    9999 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/202d562f-b077-4a08-8b65-68db1da5704f.__AC_SR200,225___.jpg

    6000 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/31517678-ddc6-4704-ad80-c53359d6ddf9.__AC_SR200,225___.jpg

    4000 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/073bce5d-4e63-4209-86d4-b08258b3101d.__AC_SR200,225___.jpg

    6000 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/2795bad8-fc4a-4136-8e4e-466747537d30.__CR0,0,200,225_PT0_SX200_V1___.png

    2000 Counts Multimeter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/7add195c-9530-4c34-a3bf-5ffa2c2ebf32.__AC_SR200,225___.jpg

    6000 Counts Multimeter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/15c437ef-eaf6-4f6c-be4c-b4091dd997d7.__CR0,0,200,225_PT0_SX200_V1___.jpg

    Pen Type Multimeter

    Customer Reviews
    Price
    Security Level
    CAT III 1000V CAT III 600V CAT III 600V CAT III 600V CAT III 1000V CAT III 600V CAT II 600V
    AC Current
    100A/600A/1000A 6A/60A/800A 1A/40A/600A 6A/60A/800A 200uA/2000uA/20mA/200mA/10A 600uA/6000uA/60mA/600mA/6A/10A -
    DC Current
    100A/600A/1000A - - 6A/60A/800A 200uA/2000uA/20mA/200mA/10A 600uA/6000uA/60mA/600mA/6A/10A -
    AC Voltage
    1V/10V/100V/750V 600mV/6V/60V/600V 4V/40V/400V/600V 600mV/6V/60V/600V 2V/20V/200V/600V 6V/60V/600V 10mV-600V
    DC Voltage
    1V/10V/100V/1000V 600mV/6V/60V/600V 400mV/4V/40V/400V/600V 600mV/6V/60V/600V 200mV/2V/20V/200V/600V 600mV/6V/60V/600V/600V 0.1mV-600V
    Capacitance
    10nF - 100mF(8 Ranges) 60nF-60mF(7 Ranges) 4nF - 40mF(7 Ranges) 60nF-60mF(7 Ranges) 4uF-2000uF 60nF - 60mF (7 Ranges) 10nF- 40mF
    Resistance/Frequency/DutyCycle
    Resistance/Frequency/DutyCycle Resistance/Frequency/DutyCycle Resistance Resistance/Frequency/DutyCycle Resistance/Frequency Resistance/Frequency Resistance/Frequency
    NCV/Continuity
    NCV/Continuity(=50O±30O) NCV/Continuity(=50O±10O) NCV/Continuity(=50O) NCV/Continuity(=50O±10O) Continuity NCV/Continuity NCV/Continuity
    Clamp Size
    40MM 26MM 26MM 26MM - - -
    Power Source
    2 x 4.5V AAA Battery(Included) 2 x 3V AAA Battery(Included) 2 x 3V AAA Battery(Included) 2 x 3V AAA Battery(Included) 1 x 9V Battery(Included) 2 x 1.5V AAA Battery(Included) 2 x 1.5V AAA Battery(Included)
    Range Selection
    Auto/Manual Auto/Manual Auto Auto/Manual Auto Auto/Manual Auto/Manual
    Temperature Detection
    ? ? ? ? ? ? ?
    9999 Counts 1000A AC/DC Digital Clamp Multimeter with Color Screen

    Warranty & Returns

    Warranty, Returns, And Additional Information

    Warranty

    • Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
    • CONTACT

    Return Policies

    Manufacturer Contact Info

    LOADING...