    KEHIPI Digital Clamp Meter 6000 Count - 800A AC/DC Current AC/DC Voltage Multi Tester, TRMS NCV Continuity Capacitance Resistance Frequency Diode LPF LOZ Test

    • MULTI-PURPOSE CLAMP METER: AC/DC Current, Accurate AC/DC Voltage , Frequency, Duty Cycle, Diode, Capacitance and Resistance Measurement. Unique DC current measurement
    • CLAMP JAW measures AC current up to 28mm without interrupting the circuit, which makes it much safer to use on mains cables and high current loads in vehicles
    • AUTO-RANGING WITH NCV: The 6000 Counts meter will automatically select the appropriate decimal point place due to auto range; NCV detects the existence of AC voltage on conductors and cables in-wall, troubleshooting electrical problems in a safe way
    • ADD LOWZ & LPF: Low impedance (LoZ) mode for identifying and eliminating ghosting or stray voltages. Low Pass Filter (LPF) for accurate measurement of variable frequency drive signals when measuring motors and transformer. Only one wires can be measured at a time. if two or more wires are measured at the same time, the measurement reading will be incorrect
    • EASY TO USE & READ: Small and Portable to Carry and Use. High Resolution, Large Backlit LCD Screen Improves Visibility. The flashlight can Access Measurement in a Dark Place. Low Battery Display.Widely used in your life. A soft zippered pouch included keeps everything neatly together and organized
    +
    +
    Overview
    Specs
    Reviews
    avatar

    Any questions? Our AI beta will help you find out quickly.

    Proster Multi-test Series

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/fe3f4467-850a-463f-877a-92256fa5f0c2.__CR184,0,1588,1786_PT0_SX200_V1___.jpg

    Clamp Meter 6000count

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/7d14ac69-26e5-457d-8696-86facebdf08e.__CR400,0,1600,1800_PT0_SX200_V1___.jpg

    Clamp Meter Color Screen

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/88c8e8e4-7fab-4106-a44e-263a0ba973b2.__CR0,0,200,225_PT0_SX200_V1___.jpg

    Updated Multimeter 6000

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/b9c8d8b2-3cf8-4e4b-a0c2-024dedb8f55d.__CR0,0,200,225_PT0_SX200_V1___.jpg

    Multimeter 6000 Count

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/5a117a44-0292-496e-abd8-69dc790622a5.__CR0,0,200,225_PT0_SX200_V1___.jpg

    TRMS Multimeter 6000

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/faa1a739-5937-4809-a58b-50da5458fd10.__CR378,0,1512,1701_PT0_SX200_V1___.jpg

    Proster LCR Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/a3718708-e761-4cdd-b3e5-1b1d5beaf931.__CR194,0,1511,1700_PT0_SX200_V1___.jpg

    Proster LCR Meter

    Customer Reviews
    Price
    DCV/ACV
    ? ? ? ? ? ? ?
    DCA/ACA
    ? ? ? ? ? ? ?
    Inductance
    ? ? ? ? ? ? ?
    Capacitance
    ? ? ? ? ? ? ?
    Resistance
    ? ? ? ? ? ? ?
    PST219
    PST219
    Digital Clamp Meter
    Digital Clamp Meter
    Digital Clamp Meter
    Digital Clamp Meter
    Digital Clamp Meter
    Digital Clamp Meter

    Proster Multi-test Series

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/fe3f4467-850a-463f-877a-92256fa5f0c2.__CR184,0,1588,1786_PT0_SX200_V1___.jpg

    Clamp Meter 6000count

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/7d14ac69-26e5-457d-8696-86facebdf08e.__CR400,0,1600,1800_PT0_SX200_V1___.jpg

    Clamp Meter Color Screen

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/88c8e8e4-7fab-4106-a44e-263a0ba973b2.__CR0,0,200,225_PT0_SX200_V1___.jpg

    Updated Multimeter 6000

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/b9c8d8b2-3cf8-4e4b-a0c2-024dedb8f55d.__CR0,0,200,225_PT0_SX200_V1___.jpg

    Multimeter 6000 Count

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/5a117a44-0292-496e-abd8-69dc790622a5.__CR0,0,200,225_PT0_SX200_V1___.jpg

    TRMS Multimeter 6000

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/faa1a739-5937-4809-a58b-50da5458fd10.__CR378,0,1512,1701_PT0_SX200_V1___.jpg

    Proster LCR Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/a3718708-e761-4cdd-b3e5-1b1d5beaf931.__CR194,0,1511,1700_PT0_SX200_V1___.jpg

    Proster LCR Meter

    Customer Reviews
    Price
    DCV/ACV
    ? ? ? ? ? ? ?
    DCA/ACA
    ? ? ? ? ? ? ?
    Inductance
    ? ? ? ? ? ? ?
    Capacitance
    ? ? ? ? ? ? ?
    Resistance
    ? ? ? ? ? ? ?
    PST219
    PST219
    Digital Clamp Meter
    Digital Clamp Meter
    Digital Clamp Meter
    Digital Clamp Meter
    Digital Clamp Meter
    Digital Clamp Meter

    Specification:

    Max display:6000

    DCV: 600mV/6V/60V/600V ±(0.5%+5)

    ACV: 6V/60V/600V ±(0.8%+5)

    DCA: 60A/200A/800A ±(1.5%+5)

    ACA: 60A/200A/800A ±(1.5%+5)

    Resistance: 600/6k/60k/600k/6M/60M ±(0.8%+1)

    Capacitance: 6nF/60nF/600nF/6uF/60uF/600uF/6mF/60mF ±(2.5%+5)

    Frequency: 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz ±(0.5%+4)

    Temperature: (-40~1000 )/(0~1832 ) ±(1.0%+5) Resolution: 1/1

    Clamp opens:28mm

    LowZ:

    LPF:

    Diode test:

    Continuity test: Less than 50±10, it will be shown OL when it is above 600

    Low battery indicator:Approx. less than 2.4 V

    Data hold:

    NCV:

    Auto power off:About 15 minutes

    Trms test:

    Function protection:

    Clamp light:

    Backlight display:

    Input impedance:10M

    Sampling rate:3 times/s

    AC frequency response: Current 40-1kHz/ voltage 40-2kHz

    Operation method:Auto or manual range

    Battery:3V (2*AAA battery)

    General Characteristic:

    Meter color:Orange and Black

    Meter weight:About 200g (including battery)

    Meter size: 185mm×65mm×32mm

    Standard accessory:Test leads, battery, manual, temperature probe,alligator clip

    Notes

    1. All clamp meters can measure current through a single wire, if you put two wires into the clamp jaw, the reading will be zero, only from one wire, you will get exact digits.

    2. Measure one wire in one time. If measure more than one wires in one time, the reading will be inaccurate.

    3. When measuring current, to get more accurate readings, the ambient temperature must be 0 to 40.

    Warranty & Returns

    Warranty, Returns, And Additional Information

    Warranty

    • Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
    • CONTACT

    Return Policies

    Manufacturer Contact Info

    LOADING...