PV - Dedicated Automatic/Manual Transfer Switch Mini ATS Solar Auto Dual Power Switch 3P 100A AC110V Uninterrupted Power Supply DIN Rail Mount Toggle Changeover Module
- PrecautionsPhotovoltaic ATS Wiring Guide: Connect PV supply to upper terminals and continuously energized backup power to lower terminals. Ensure backup power is live for auto-transfer function and verify PV input voltage matches rated specs. Maintain voltage within ±15% of rating and current 5A to prevent coil damage.L1 and L2 denote live wires; N denotes the neutral wire; PE denotes the protective earthing wire
- Product Description Dual-Power ATS Core Functionality Quickly switches loads to backup power upon main power failure,Supports automatic/manual transfer between two power sources with real-time status monitoring. If main power (A) fails, backup power (B) activates within 0.03 seconds and automatically reverts once main power recovers.Operating Voltage:3P AC 110V 100amp, 50/60 Hz Dimensions: 6.7 x 4.5 x 3.5 inches Weight: 1.65 lbs Installation Rail Mounting: Compatible with standard DIN rails
Any questions? Ask CelesteSM will help you find out quickly.
Automatic Mode Automatic Mode: For 110V AC ATS in auto mode, set left switch to "Auto" and green handle to "Source A". When normal power A works, A (red) stays on; if A fails, it switches to backup B within 0.06s (A red off, B red on), and reverts when A recovers.
Manual Mode For ATS in manual mode, set left switch to "Manual". Choose A: turn right green handle to "Source A" (A red on). Choose B: turn handle to "Source B" (B red on).
Q1Can I use a PV inverter as normal power or reserve power?
Answer: Yes. For photovoltaic (PV) type automatic transfer switches, please select models prefixed with "PV", such as PV 3P 100A.
Q2: Will household appliances lose power when this ATS transfer?
Answer: No. Since the transfer only takes 8msa remarkably fast speedhousehold appliances will not lose power.
Q3: Will this ATS give the generator a start signal to automatically turn it on?
Answer: Yes.
Q4:Can we use 110V to connect this ATS?
Answer:Please select the 110V model of the ATS
Q5:What is the installation method of this ATS?
Answer:Rail mounting (refers to installation on a standard DIN rail)
The voltage of the common and backup power supplies must be within 85%110% of the rated voltage, and the current must not be less than 5A; otherwise, the coil may overheat or even get damaged.
Suitable common and backup power sources for this product include stable municipal power, photovoltaics, generators, etc. They must be alternating current (AC); otherwise, the product will not switch automatically.
NOTE





Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: 30 days
- This item is covered by Grandwood Tech Limited Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory