LIFE-SUPPORT MEDICAL DEVICE COMPONENT HIGHEST LEVEL OF CAUTION
This battery is a critical component of a regulated Class III medical device (defibrillator). Its performance directly impacts patient safety. Use and replacement are governed by strict clinical and regulatory protocols.
SPECIFICATIONS & COMPATIBILITY
Primary Battery Model: CMLI3X4I003B (Compatible Replacement, High-Capacity ~6800mAh)
Also Replaces: CMLI2X4I005B (~5000mAh), CMLI2X4I002B, CML13X41003B, CML12X41005B, CML12X41002B.
Voltage: 14.4V
Typical Capacities: 97.92W h (~6800mAh) for CMLI3X4I003B; 72Wh (~5000mAh) for CMLI2X4I005B. Confirm which capacity your device requires.
Chemistry: Lithium-Ion (Li-ion)
Condition: 100% Brand New, Medical-Grade Cells
Compatible Device: Comen S8 Series Patient Monitor / Defibrillator.
WHY MEDICAL-GRADE BATTERY SPECIFICATIONS ARE NON-NEGOTIABLE
Defibrillator Energy Reserve: The battery must reliably charge the device's high-voltage capacitors to the precise energy level selected for defibrillation.
Monitoring Uptime: Provides extended runtime for continuous ECG, SpO2, NIBP, and EtCO2 monitoring during transport or in areas without AC power.
Device Self-Tests: Powers the daily/weekly automated self-tests that verify the defibrillator's readiness for use.
Patient Safety: A failing or incompatible battery can render the entire life-saving device inoperable.
MANDATORY SAFETY, INSTALLATION & COMPLIANCE PROTOCOLS
Authorized Personnel Only: Battery replacement MUST be performed by certified biomedical technicians (BME
Ts) or clinical engineering staff following the Comen S8 Service Manual.
Device Decontamination: If the defibrillator is used in patient care, ensure all applicable disinfection protocols are completed before and after servicing.
Use Comen Approved Charger Only: Charge exclusively with the official Comen S8 AC power adapter/charger. Using any other charger is a critical safety violation that risks battery/device failure and voids compliance.
Post-Installation Testing: After installation, the entire Comen S8 device must undergo a full performance verification test, including a defibrillation energy output test (discharged into a test load), as per the manufacturer's instructions and hospital policy.
Regulatory Compliance: Using non-OEM parts may affect the device's regulatory status (e. g., FDA, CE Mark). The facility's Clinical Engineering department must approve and document the use of this compatible part.
PACKAGE INCLUDES
1 x CMLI3X4I003B / CMLI2X4I005B Compatible Replacement Battery ( 14.4V, High Capacity)