DIN Rail Power Supplies Trio-ps/1ac/24dc/10 Trio 24v 10a 1phase
- Worldwide use of wide-range output and international approval package
- High reliability through high MTBF >500 000 hrs
- Parallel switch bar for increased output and redundancy
- Simplified operation by LED fault monitoring
- Balancing of voltage cases and charging of battery by adjustable output voltage.
+
+
Overview
Specs
Reviews
Any questions? Ask CelesteSM will help you find out quickly.
Try me now
Input data Nominal input voltage range 100 V AC ... 240 V AC
Input voltage range 85 V AC ... 264 V AC (Derating <90 V AC: 2,5 % / V)
Dielectric strength maximum 300 V AC
AC frequency range 45 Hz ... 65 Hz
Discharge current to PE <3.5 mA
Inrush surge current <15 A
Power failure bypass > 24 ms (120 V AC)
> 24 ms (230 V AC)
Input fuse 6.3 A (slow-blow, internal)
Choice of suitable circuit breakers 10 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi) 0.99
Type of protection Transient surge protection
Protective circuit/component Varistor
Back to top Output data Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage 22.5 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current 10 A (UOUT = 24 V DC)
Derating 55 °C ... 70 °C (2.5%/K)
Connection in parallel Yes, for redundancy and increased capacity
Connection in series Yes
Max. capacitive load Unlimited
Active current limitation Approx. 14 A (for short-circuit)
Control deviation <1 % (change in load, static 10 % ... 90 %)
<2 % (change in load, dynamic 10 % ... 90 %)
<0.1 % (change in input voltage ±10 %)
Residual ripple <10 mVPP
Output power 240 W
Typical response time <1 s
Peak switching voltages nominal load <50 mVPP
Maximum power dissipation in no-load condition 6.7 W
Power loss nominal load max. 30 W
Input voltage range 85 V AC ... 264 V AC (Derating <90 V AC: 2,5 % / V)
Dielectric strength maximum 300 V AC
AC frequency range 45 Hz ... 65 Hz
Discharge current to PE <3.5 mA
Inrush surge current <15 A
Power failure bypass > 24 ms (120 V AC)
> 24 ms (230 V AC)
Input fuse 6.3 A (slow-blow, internal)
Choice of suitable circuit breakers 10 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi) 0.99
Type of protection Transient surge protection
Protective circuit/component Varistor
Back to top Output data Nominal output voltage 24 V DC ±1 %
Setting range of the output voltage 22.5 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current 10 A (UOUT = 24 V DC)
Derating 55 °C ... 70 °C (2.5%/K)
Connection in parallel Yes, for redundancy and increased capacity
Connection in series Yes
Max. capacitive load Unlimited
Active current limitation Approx. 14 A (for short-circuit)
Control deviation <1 % (change in load, static 10 % ... 90 %)
<2 % (change in load, dynamic 10 % ... 90 %)
<0.1 % (change in input voltage ±10 %)
Residual ripple <10 mVPP
Output power 240 W
Typical response time <1 s
Peak switching voltages nominal load <50 mVPP
Maximum power dissipation in no-load condition 6.7 W
Power loss nominal load max. 30 W
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: 30 days
- This item is covered by Forestgrand Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory
LOADING...