Specifications: AC
Current Range: 60A/600A( 2.5 %rdg+3dgt)AC
Current Resolution: 10mA/100mADC
Current Range: 60A/600A(3%rdg+3dgt)DC
Current Resolution: 10mA/100mAAC
Voltage Range: 6V/60V(1%rdg+4dgt), 600V( 1.2 %rdg+10dgt)AC
Voltage Resolution: 1mV/10mV/100mVDC
Voltage Range: 600mV/6V/60V( 0.5 %rdg+5dgt), 600V( 0.8 %rdg+5dgt)DC
Voltage Resolution: 0.1 mV/1mV/10mV/100mVTemperature
Range: -20~1000(-4~1832)( 1.0 %+3)rdgTemperature
Resolution: 1 (1)
Resistance Range: 600/6k/60k/600k/6M( 0.8 %rdg+5dgt), 60M( 1.2 %rdg+5dgt)Resistance
Resolution: 0.1 /1/10/100/1k/10kFrequency
Range: 60Hz/600Hz/6kHz/60kHz/600kHz/10MHz( 1.5 %rdg+5dgt)Frequency
Resolution: 0.01H z/ 0.1H z/ 0.001 kHz/ 0.01 kHz/ 0.1 kHz/ 0.001MH zCapacitance
Range: 60nF/600nF/6F/60F/600F/6mF( 4.0 %rdg+5dgt), 100mF( 5.0 %rdg+5dgt)Capacitance
Resolution: 0.01 nF/ 0.1 nF/1nF/10nF/100nF/ 0.1F / 0.001 mFMaterial: ABS
Range: Auto
rangingDisplay: 6000 counts displaySafety
Standard: 600V CAT II, pollution
grade: 2Conversion
Rate: Approx. 3s/secondTest or
Calibrate Surrounding Temperature: 202The Biggest Voltage Between Measurement End and
Ground: 600VData
Hold Function: YesAuto
Power-off: 15
minutesOverload: "OL"
displayedAltitude: <2000mWorking Temperature: 0~40 (<80%RH, not considered <10)Storage Temperature: -10~60 (<70%RH, take off battery)Power Supply: 2 * 1.5V AAA battery (NOT included)Clamp Open Size: 25mm / 0.98inItem Size: 185 * 65 * 25mm / 7.28 * 2.56 * 0.98inItem Weight: 155g / 5.49ozPackage Weight: 332g / 11.74ozPackage Size: 21.5 * 11 * 4cm / 8.46 * 4.33 * 1.57in Features:Multiple Functions: the clamp meter can be used to measure AC/DC current, AC/DC voltage, temperature(/), resistance, frequency, capacitance, diodes and buzzer.Safety Operation: the product is designed in accordance with the safety standards for electronic measuring instrument. Comply with safety standards of IEC61010-1 and 600V CAT and pollution degree 2.Low Power Consumption: powered by 2pcs AAA batteries, with low battery indicator and 15 minutes auto off functions to save power.NCV Test: simply place the sensing area of the clamp head close to the object to be tested (such as power distribution boards, wiring boards, and places with strong electric fields, etc.), once the AC electric field or voltage(> 20V) is induced, the NCV LED will flash continuously and quickly.
Clearly Display: 1.6 -inch LCD screen with a backlight, allowing you to check the measurement display in a dark place.
Practical Applications: with high measurement accuracy, fast response, and high safety level, and no change in long-term use in accuracy, perfectly for apply in electric engineering and electrical appliance repairing areas.