Your Browsing History
Meet Your Seller
2Pcs 1 Channel Switch Relay Module Modbus Rtu Switching Input Output Relays Board with Anti-Reverse Connection Protection RS485 TTL Communication
- The 1 Channel Modbus relay module is equipped with mature and stable 8-bit MCU and RS485 level communication chips. RS485 communication protocol using standard MODBUS RTU format can realize 1-way input signal detection and 1-way relay output, which can be used in digital quantity detection or power control occasions. Device address: range 1-255, default 255, support power-down saving Baud rate, input signal, relay status, equipment address can be read using software/instructions Onboard relay switch indicator
+
+
Overview
Specs
Reviews
Any questions? Our AI mode will help you find out quickly.
Try me now
On-board mature and stable 8bit MCU and MAX485 level conversion chips;
Output signal: relay switch signal, supports manual, flash-off and flash-off modes, the delay base of flash-off/flash-off is 0.1S, and the maximum flash-off/flash-off time can be set to be 0xFFFF * 0.1S = 6553.5S; Onboard 1 Channel 5V, 10A/250V AC 10A/30V DC relay, which can be continuously closed for 100, 000 times, with diode laxative protection, short response time;
Communication protocol: supports standard Modbus RTU protocol, communication
interface: supports RS485/TTL UART interface, communication
baud rate: 4800/9600/19200, default 9600bps, supports power failure storage;
Optocoupler input signal range: DC 3.3 -30V (this input cannot be used for relay control);
Power supply voltage: DC7-24V, supports DC seat/ 5.08 mm terminal power supply, with input anti-reverse connection protection
Output signal: relay switch signal, supports manual, flash-off and flash-off modes, the delay base of flash-off/flash-off is 0.1S, and the maximum flash-off/flash-off time can be set to be 0xFFFF * 0.1S = 6553.5S; Onboard 1 Channel 5V, 10A/250V AC 10A/30V DC relay, which can be continuously closed for 100, 000 times, with diode laxative protection, short response time;
Communication protocol: supports standard Modbus RTU protocol, communication
interface: supports RS485/TTL UART interface, communication
baud rate: 4800/9600/19200, default 9600bps, supports power failure storage;
Optocoupler input signal range: DC 3.3 -30V (this input cannot be used for relay control);
Power supply voltage: DC7-24V, supports DC seat/ 5.08 mm terminal power supply, with input anti-reverse connection protection
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: 30 days
- This item is covered by Kepler Forge Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory
LOADING...