Minuteman RPM308I2LCD-HW 8-Outlets PDU - Switched - IEC 60320 C20 - 8 x IEC C13 - Network (RJ-45) - 0U - Horizontal/Vertical - Rack-mountable
- The Minuteman RPM EV6 and LCD (Remote Power Manager) Switched PDU series is the ultimate power nerve center for controlling multiple network devices and services. The RPM EV6 and LCD PDUs allow for remote management, monitoring of PDU vitals, and control of outlets and networked clients.
- Power status can be monitored over the network, via a web browser and/or SNMP card, allowing for full control to remotely reboot connected equipment by switching the outlet on and off.
- Features include mail notification, threshold sensing, overload alerts, power sequencing, and central management - via the free centralized monitoring software.
- Network Connection: The RPM is a smart IP-based PDU that connects to your network via CAT5 cable
- Control Individual Outlets: Power on/off, reboot, and monitor up to 24 individual devices from a single IP address
+
+
Specs
Reviews
Any questions? Ask CelesteSM will help you find out quickly.
Try me now
Learn more about the MINUTEMAN RPM308I2LCD-HW
| Brand | MINUTEMAN |
|---|---|
| Model | RPM308I2LCD-HW |
| Type | Power Distribution Units |
|---|---|
| Style | Horizontal Installation, 0U Vertical Installation |
| Certifications | 62368-1 Certification |
| Input Voltage | 208V |
|---|---|
| Maximum Input Current | 30A |
| Input Connector(s) | Hardwire |
| Cord Length | 10 ft |
| Output Connector(s) | Rear Panel Receptacles: (8) C13 |
|---|---|
| Maximum Output Current | 30A |
| Overload Protection | Input Circuit Breaker Protection |
| Features | IP-addressable Remote Power Manager Built-in Web Server to support Remote Power Management Event Notifications via Email or SNMP Traps Local LCD displays Amps, IP Address, Temperature and/or Humidity Daily, Weekly, Monthly & Yearly Power Consumption Data 10/100 Base-T Ethernet Port IPv4, IPv6 Support and SNMP Support (v1,v2c,v3) Telnet, SSH Encryption Support Radius Authentication User Account for Three Different Permissions Management Systems Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm SSL Web Browser for Set Up and Operation IP Address Filtering Maximum 5,000 Entries for Each Power Consumption Data and Event log Remote Firmware Upgrade Support SNMP Heart Beat Trap Available Reports in Fahrenheit or Celsius Export and Import RPM Configuration True RMS Current Measurement Provides Voltage, Frequency, Power Factor, Active Power, Apparent Power and kWh information Remote Outlet On/Off Power Switching Remote Outlet Current Monitoring User Defined Alarm Thresholds for Warning and Overload User Defined Power On/Off Sequence Timing Timed & Scheduled On/Off/Reboot Switching Alternative Outlet Restart Mode: Memorize Previous Status, Always On or Always Off Ping No-Answer Alarm Outlet Action via Preset-Event: Including Power Event, Environment Event and Receiving Trap from Other Devices Circuit Breaker Protection Free Bundle Management Utility |
|---|
| First Listed on Newegg | June 10, 2025 |
|---|
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Limited Warranty period (parts): 3 years
- Limited Warranty period (labor): 3 years
- Read full details
Return Policies
- Contact Manufacturer for Assistance
- This item is covered by Newegg.com's Manufacturer Warranty Only Return Policy.
- Read full return policy for details.
Manufacturer Contact Info
- Manufacturer Product Page
- Manufacturer Website
- Support Phone: 1-800-238-7272
- Support Email: mmsupport@minutemanups.com
- Support Website
- View other products from MINUTEMAN
LOADING...
The Minuteman RPM308I2LCD-HW is a network-managed, switched 208V PDU with eight IEC C13 outlets, designed for IT teams that need to monitor and remotely power-cycle equipment in a rack.
Recommended For
- IT administrators managing a 208V rack who need to switch or reboot individual C13-connected devices remotely through a browser or SNMP.
- Network and server teams supporting equipment at remote or unmanned sites, where remote outlet control can reduce trips to power-cycle a device.
- Rack operators who want scheduled power-on, shutdown, or restart actions, plus auto-ping monitoring and alerts for connected equipment.
- Teams consolidating up to eight 208V C13-powered devices in a rack and needing horizontal or 0U vertical mounting.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | Rack-mounted network equipment that needs individually switched outlets, remote power control, and monitoring |
| Input And Output Power | 208V input, rated for up to 30A input and output; hardwire input with an 8-receptacle rear panel of C13 outlets and a 10 ft cord |
| Installation And Form Factor | Supports horizontal installation or 0U vertical rack installation |
| Remote Outlet Control | Remotely switch outlets on or off, reboot connected equipment, monitor outlet current, and configure timed or scheduled switching, power-on sequencing, and restart behavior |
| Network Management And Security | IP-addressable management through a built-in web server and 10/100 Base-T Ethernet; supports IPv4, IPv6, SNMP v1/v2c/v3, Telnet, SSH, SSL web access, RADIUS authentication, IP filtering, and three permission levels |
| Power Monitoring And Reporting | LCD reports amperage, IP address, and temperature and/or humidity; provides true RMS current, voltage, frequency, power factor, active and apparent power, and kWh, with consumption history and event logs of up to 5,000 entries each; reports temperature in Fahrenheit or Celsius |
| Alerts And Protection | Input circuit-breaker protection; configurable warning and overload thresholds with notifications by email, SNMP, syslog, LED, or audible alarm, plus ping no-answer alerts and SNMP heartbeat traps |
| Automation And Configuration | Supports event-triggered outlet actions, configuration export and import, remote firmware upgrades, and a bundled management utility |
| Dimensions And Weight | 17 × 8.5 × 1.8 inches; 8.8 lb |
| Certification | 62368-1 certified |
| Model Identifiers | Minuteman RPM308I2LCD-HW |