Vertiv Liebert POD PD2 - (4) NEMA 5-20R| (2) L6-30R| (2) L6-20R| UPS Maintenance - Hardwire 4-wire (2PH+N+G) Input Connector | 60A|POD for GXT4 8-10kVA models| PD2-104
Any questions? Ask CelesteSM will help you find out quickly.
For installation flexibility, Vertiv Liebert GXT4 8-10kVA UPS models allow you to choose from several different input/output power wiring configurations made possible by the use of removable power output distribution boxes (PODs) installed in the rear of the UPS. When the ease of plug-and-play power connections is desired, optional versions of the power distribution box convert Vertiv Liebert GXT4 8-10kVA UPS units to a hardwire input with receptacles for output distribution, and also offers maintenance bypass capability that allows hot-swapping of the entire UPS without interruption of power to the connected load.
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Limited Warranty period (parts): 2 years
- Limited Warranty period (labor): 2 years
- Read full details
Return Policies
- Contact Manufacturer for Assistance
- This item is covered by Newegg.com's Manufacturer Warranty Only Return Policy.
- Read full return policy for details.
Manufacturer Contact Info
- Manufacturer Product Page
- Manufacturer Website
- Support Phone: 1-800-543-2378
- Support Website
- View other products from Liebert
The Vertiv Liebert PD2-104 is a 60A power distribution and maintenance-bypass unit for Liebert GXT4 8–10kVA UPS systems, suited to data-center and IT teams that need to distribute power to equipment with mixed NEMA 5-20R, L6-20R, and L6-30R plugs.
Recommended For
- IT teams maintaining a Vertiv Liebert GXT4 8–10 kVA UPS in a server room or network closet who need to move connected equipment to bypass power while servicing or replacing the UPS.
- Data-center and infrastructure teams distributing power to a mix of equipment that needs NEMA 5-20R, L6-20R, and L6-30R connections from a compatible UPS.
- Facilities teams or electrical contractors fitting out a fixed UPS installation with hardwired input and receptacle-based output, where the site is equipped for the required high-current electrical connection.
- Organizations that want an output-distribution module matched to a compatible Liebert UPS, rather than a standalone rack PDU, and value a maintenance-bypass path for planned UPS work.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | UPS maintenance and power distribution for Liebert GXT4 8–10 kVA systems, with mixed outlet types |
| Output Receptacles | 8 outlets: 4 NEMA 5-20R, 2 NEMA L6-20R, and 2 NEMA L6-30R |
| Input And Electrical | 60 A; hardwired terminal block input, 3W + G |
| Physical Specifications | 20.7 × 12 × 8.8 in; 6.60 lb |
| Model Identifiers | Liebert PD2-104 PDU |