Features: Higher Availability
Provides utility power to attached equipment when switched to maintenance bypass mode.
Allows UPS maintenance or replacement of the UPS without discontinuing power to critical equipment.
Flexibility
Easily installed - the UPS and utility power are both connected to the MicroPOD with the supplied cords.
Allows scheduled UPS maintenance to ensure continuous uptime without having to shut down protected equipment.
Rotary switch with indicators make the unit simple to operate.
Plug-and-play connectability for both input and output.
Compatible with any brand of UPS system.
Lowest Total Cost Of Ownership
Assures system uptime during maintenance activities.
Extreme affordability.
Features: Package Contents:
Metered PDU3MV6L2130 48-Outlets 8.6kW PDU
Cord Retention Brackets
Rack Mounting Brackets
Owner's Manual
Current:24 A Input Current
Number of Output Connections:36
6
Output Receptacles:36 x IEC 60320 C13
6 x IEC 60320 C19
6 x NEMA 5-15/20R
Power Rating:8.60 kVA
Power Rating:8.60 kVA
Product Name:Metered PDU3MV6L2130 48-Outlets 8.6kW PDU
Input Receptacles:NEMA L21-30P
Product Type:PDU
Form Factor:Zero U
Form Factor:Zero U Vertical Rackmount
Dimensions: 70.0" Height x 2.7" Width x 2.2" Depth
Front Panel LEDs: 8 LEDs display power on-off status for each C13 output receptacle, plus 2 additional LEDs to indicate input power status for primary and secondary inputs
Certifications: Tested to UL 60950-1 (USA, Canada), CE (EU), NOM (Mexico), GOST (Russia), EN55032:2015 and EN62040-2:2006, FCC Class A (Emissions), TAA Compliant
Front Panel LEDs: 8 front panel LEDs display power on - off status for each C13 outlet, plus 2 LEDs for power status on Primary and Secondary input connection. Digital current meter display shows the amount of power consumption in amps for entire PDU output.
Certifications: Tested to UL 60950 (USA, Canada), CE (Europe), Class A (Emissions), NOM (Mexico), RoHS Complaint
Front Panel LEDs: Set of 3 diagnostic LEDs continuously report status for LINE OK (green), suppressor or wiring FAULT (red) and PROTECTION PRESENT (green)
Certifications: Tested to UL1449 3rd Edition (USA) and CSA (Canada), RoHS Compliant
Front Panel LEDs: 8 LEDs display power on-off status for each C13 output receptacle, plus 2 additional LEDs to indicate input power status for primary and secondary inputs
Certifications: Tested to UL 60950 (USA, Canada), CE (Europe), Class A (Emissions), NOM (Mexico)
Certifications: Tested to UL60950-1: 2007 R10.14 (USA), CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011+A2: 2014 (Canada), FCC CLASS A PART 15 (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant