Features: Package Contents:
Dominion PX DPXS20-20 20-Outlets 1.9kVA PDU
Rack Mount Brackets
Power Rating:1.90 kVA
Power Rating:1.90 kVA
Number of Output Connections:20
Current:20 A Line Current Per Phase
20 A Maximum Current Draw
Output Receptacles:20 x NEMA 5-15R
Product Name:Dominion PX DPXS20-20 20-Outlets 1.9kVA PDU
Input Receptacles:NEMA 5-20P
Product Type:PDU
Interfaces/Ports:RJ-45 10/100Base-T Ethernet
RJ-45 RS-232
Form Factor:Zero U
Form Factor:Zero U Rack-mountable
Dimensions: 2.6" Height x 2.0" Width x 60.6" Depth
Features: Package Contents:
Dominion PX-2000 PX2-2180R 8-Outlets 3.3kVA PDU
Rack Mount Brackets
Current:16 A Rated Current
20 A Line Current
20 A Maximum Current Draw
Form Factor:1U
Form Factor:1U Horizontal Rackmount
Power Rating:3.30 kVA
Power Rating:3.30 kVA
Number of Output Connections:8
Output Receptacles:8 x IEC 60320 C13
Interfaces/Ports:DB-9 RS-232 Serial
RJ-12
RJ-45
RJ-45 10/100Base-T Ethernet
Type A USB
Type B USB
Product Name:Dominion PX-2000 PX2-2180R 8-Outlets 3.3kVA PDU
Input Receptacles:NEMA L6-20P
Product Type:PDU
Features: Power Rating:5.76 kVA
Form Factor:Vertical Rackmount
Product Type:PDU
Color:Black
Power Rating:5.76 kVA
Form Factor:Vertical Rackmount
Input Receptacles:1 x NEMA L14-30P
Product Name:ePDU Metered EMI200-10 34-Outlet PDU
Output Receptacles:20 x IEC 60320 C13
6 x IEC 60320 C19
8 x NEMA 5-20R
Specifications: Switch Type: Open Transition
Switching Time: 6 ms
Plug/Connector Type:
Hardwired
NEMA 5-15P
Receptacles:
Hardwired
NEMA 5-15R
Protection Type:
Over Current
Surge
Input Voltage: 110 V AC
Input Voltage Range: 120 V AC
Output Voltage:
120 V AC
208 V AC
Current:
12 A Rated Current
15 A Maximum Current
Frequency:
50 Hz
60 Hz
Temperature:
32 degrees F (0 degrees C) to 104 degrees F (40 degrees C) Operating
-4 degrees F (-20
Specifications: Load Rating: 20 amps @ 120 volts
Maximum Load Inrush Energy: 1400 Joules total during power-up
UL 1449 Adjunct Classification Test Results: 1000 surges, 6000 volts, 3000 amps, B3 pulse; Measured suppressed voltage: 170 volts; no failures
Federal Guidelines: Grade A, Class 1, Mode 1(CID A-A-55818)
EMI/RFI Filter, Normal Mode (50-ohm load): > 30 dB 100 KHz - 50 MHz
EMI/RFI Filter, Common Mode (50-ohm load): > 20 dB 1 MHz - 50 MHz
Under-Voltage Auto Shutdown: Adjustable from 90V to 110V
Over-Voltage Auto Shutdown: Adjustable from 130V to 150V
Endurance (C62.41-1991 Category B3 pulses): 1 kV>500,000; 3 kV>10,000; 6 kV>1000
Control Inputs: Momentary Switch, Latching Switch,Contact Closure or 5-30 Vdc
Input Control Current: 3 mA
DC Voltage Output: 12 Vdc, 40 mA maximum load
Auxiliary Relay Cont...