Vertiv Liebert PSI5-2200RT120LI PSI5 Lithium-Ion UPS 1920VA/1920W 120V AVR Rack/Tower - 2U Line Interactive UPS| Remote Management Capable| With Programmable Outlets
- Status Indicators LCD Display
- Maximum Operating Temperature 104°F (40°C)
- Circuit Breaker Yes
- Waveform Type Pure Sine Wave
- Load Capacity (VA) 1920 VA
- Load Capacity (Watt) 1920 W
- Battery Life 10 Year
- Battery Chemistry Lithium Ion (Li-Ion)
- Hot Swappable Yes
- Backup/Run Time (Half Load) 20 Minute
- Backup/Run Time (Full Load) 9 Minute
- Typical Battery Recharge Time 2.10 Hour
- VGA No
- Network (RJ-45) Yes
- Modem (RJ-11) Yes
- Serial Port No
- EPO Port Yes
- USB (HID Compliant) Port Yes
- Application/Usage: Network Equipment, Mission Critical Equipment, Server
- Dataline Protection RJ-11/RJ-45
- Emergency Power OFF Yes
- Plug/Connector Type NEMA L5-20P
- Cord Length 10 ft
- Phase Single Phase
- Receptacle Type: NEMA L5-20R, NEMA 5-20R
- EMI/RFI Noise Filter Yes
- AVR Yes
- Transfer Time 4 ms
- Receptacle Detail: 6 x NEMA 5-20R, 1 x NEMA L5-20R
- Country of Origin China
- Environmentally Friendly Yes
- TAA Compliant No
- Energy Star No
+
+
Overview
Specs
Reviews
See all Q & A
Any questions? Ask CelesteSM will help you find out quickly.
Try me now
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Limited Warranty period (parts): 1 year
- Limited Warranty period (labor): 1 year
- Read full details
Return Policies
- Contact Manufacturer for Assistance
- This item is covered by Newegg.com's Manufacturer Warranty Only Return Policy.
- Read full return policy for details.
Manufacturer Contact Info
LOADING...
LOADING...
The Vertiv Liebert PSI5-2200RT120LI is a 1920VA/1920W, 120V line-interactive lithium-ion UPS with pure sine wave output and AVR, suited to protecting servers, network equipment, and other critical loads that need short-term backup power.
Recommended For
- IT teams protecting network closets or branch-office racks—such as switches, routers, and edge servers—who want rack/tower flexibility and a lithium-ion battery designed to reduce replacement frequency.
- Small server-room and homelab operators who need short-term battery coverage to keep rack equipment running through brief outages or allow an orderly shutdown, rather than hours of backup.
- Operators of 120V IT equipment who want line-interactive protection with automatic voltage regulation and pure sine-wave output on battery, without requiring an online double-conversion UPS.
Spec Summary
| Attribute | Value |
|---|---|
| Best For | Network equipment, servers, and other mission-critical equipment that need battery backup and power conditioning |
| Power Capacity And Output | 1920 VA / 1920 W output, with pure sine wave power and single-phase operation |
| Input And Voltage Compatibility | 120 VAC default input and output, with selectable 100/110/115/125 VAC operation; input range 75–146 VAC and frequency 55–65 Hz (57–63 Hz for battery-to-normal comeback) |
| Battery And Runtime | Lithium-ion battery with 8.6 minutes of runtime at full load and 19 minutes at half load; recharges to 90% in 2 hours, is hot-swappable, and has a stated 10-year battery life |
| Outlets And Connectivity | Seven outlets: six NEMA 5-20R and one NEMA L5-20R; NEMA L5-20P input plug with a 5-20 adapter included, plus USB, RJ-45, RJ-11, and EPO ports |
| Power Protection And Controls | Automatic voltage regulation, 4 ms transfer time, circuit breaker, EMI/RFI noise filtering, and surge protection to ANSI C62.41 Category A, Level 3 |
| Installation And Dimensions | Rack- or tower-mountable 2U design; 3.38 × 17.24 × 20.07 inches and 39.5 lb |
| Operating Environment | Operating temperature 32–104°F (0–40°C), storage temperature 5–120°F (−15–50°C), and humidity 20%–90% non-condensing |
| Model Identifiers And Approvals | Liebert PSI5 series, model PSI5-2200RT120LI; approvals include UL 1642, UL 1973, UL 1778, and CSA 22.2 No. 107.3 |