Specifications: The versatile D914 series impact tools include built-in probe pic/spudger and torque capability.
Industry standard, internationally accepted
Hook and spudger tools are built into the handle
Automatic spring handle --choose low impact for 24/26 gauge wire or high impact for 22-gauge wire
D914 and D914S impact tools accept Phillips-head or flat screwdriver blade
Convenient blade storage built into the handle
Adapter blade allows technician to use a variety of torque tool bits and sockets
Easy blade insertion, locks in place
D914STM soft touch impact tool features a rubber handle and special ergonomic design for better grip and to reduce hand fatigue
Package Contents: OptiFiber Pro OFP2-100-Q Cable Analyzer
1 x Versiv Mainframe
1 x OptiFiber Pro Quad OTDR Module
Shoulder Strap
Carry Case
USB Interface Cable
Versiv Open Source Software CD
AC Charger
Statement of Calibration and Getting Started Guides
Specifications: Test Services:
Fault Display
High Speed Testing
Generation of two tones for tracing cables and locating hidden cables
Length Measurement:
15.75" to 656 ft Twisted Pair
Ports: 1 x RJ-45
Status Indicators:
5 green LEDs for pairs and shield display
6 red LEDs (TONER, SHORT, REVERSED, MISWIRE, SPLIT PAIRS, and LOW BATTERY)
Batteries: Alkaline AAA
Features
Features
Auto-sleep mode
Generation of two tones for tracing cables and lication hidden cables
Packaging
Package Contents
MicroMapper MT-8200-49A Network Testing Device
MicroMapper Remote
Patch Cable
6-Volt Alkaline Battery
User Guide
The MicroMapper quickly and easily tests twisted pair cabling, giving you visibility of opens, shorts, crossed, reversed and split pairs. Just push the TEST button and MicroMapper will automatically scan all wire pairs for any existing faults...
Specifications: Test Services:
Graphical wiremap, length, cable ID, and distance to fault displayed on one screen.
Tests all common media types including RJ11, RJ45, Coax, with no need for adapters.
Locates virtually any cable or wire pair with IntelliTone digital and analog toning.
Verifies today's media services, including 10/100/1000 Ethernet, POTS, and PoE.
Integrated rubber holster enhances grip and makes it durable enough for the toughest jobs.
Large, backlit LCD makes results crystal clear whether in bright sunshine or in a dark closet.
Length Measurement: 11.81" to 1509 ft
Ports: RJ-45 10/100/1000Base-T Network
Connectivity Media: UTP
Display Screen: Monochrome LCD with backlight
Batteries: AA Standard
Dimensions: 3.00" x 6.40" x 1.40"
Weight (Approximate): 12.80 oz
Specifications: The versatile D914™ series impact tools include built-in probe pic/spudger and torque capability.
Industry standard, internationally accepted
Hook and spudger tools are built into the handle
Automatic spring handle --choose low impact for 24/26 gauge wire or high impact for 22-gauge wire
D914 and D914S impact tools accept Phillips-head or flat screwdriver blade
Convenient blade storage built into the handle
Adapter blade allows technician to use a variety of torque tool bits and sockets
Easy blade insertion, locks in place
D914STM soft touch impact tool features a rubber handle and special ergonomic design for better grip and to reduce hand fatigue
Specifications: User interface
Slide switch selects Continuity or Tone Mode
Push button switch selects SOLID, ALT or OFF
Tone mode LED
Continuity/Polarity LED
Solid Frequency
1000 Hz nominal
Alternating Frequency
1000/1500 Hz nominal
Over Voltage Protection
60 Vdc in Toner/Polarity Mode
Output Power in Tone Mode
8 dbm into 600 ohms
Output Voltage Level in Continuity Mode
8 Vdc with fresh battery
Battery
9V alkaline
Temperature
Operating: -20° C to 60° C, Storage: -40° C to 70° C
Case dimensions
2.7 in. x 2.4 in. x 1.4 in. (6.9 cm x 6.1 cm x 3.6 cm)
Specifications: Electrical
Loop Limit
2.4 kOmaximum at 48 VDC (nominal 15 mA minimum loopcurrent)
DC Resistance (Talk Mode)
150 Otypical at 80 mA current
AC Impedance (Monitor Mode)
Low impedance (Ring position) 600 Oat 1 KHz typical
High impedance (HI Z position) 100 kOminimum at 1 KHz
Rotary Dial Output
10 pps .5 pps
Pulsing Rate 60 % ± 2 %
Percent Break 800 ms typical
Interdigit Interval Leakage During Break
> 50 kO
DTMF Output
±1 % maximum
Tone Frequency Error Level per Tone Pair
dBm maximum, - dBm minimum
High versus Low Tone Difference
4 dB maximum
Physical
Length
8.75 in (22.2 cm)
Width
2.375 in (6.03 cm)
Height
3.375 in (8.57 cm)
Weight
10.8 oz (.307 kg) maximum
Environmental
Temperature
Operating: -5 °C to °C
Storage: -40 °C to °C
Drop
1 meter, 4 times
Altitude
To 3,000 meters (10,000 feet) maximum
Relative Humidity
10 %to 80 % (non...
Specifications: Application/Usage: Cable Termination
Additional Information:
Unique design easily accommodates close-to-wall installation.
Replaceable blade head for use with multiple jack types.
For Leviton 61110, 5G110, 6110G.
Specifications: The TS®30 Test Set top features include:
High impedance monitor mode
Automatic regulation of speech levels
Tone and pulse operation
Last number redial in tone and pulse modes
RainSafe™ weather protection for use in extreme weather conditions
Hook flash button
Fully functional with either line polarity
Audible electronic ringer for call backs
High current and over voltage protection
High impact polycarbonate case
Field replaceable spring-loaded belt clip
Hearing aid compatible receiver
Transmitter Mute switch
Talk and Monitor modes
Ergonomic design
Lightweight unit is easily transported
Package Contents: OptiFiber Pro OFP2-100-QI Cable Analyzer
1 x Versiv Mainframe
1 x OptiFiber Pro Quad OTDR Module
Shoulder Strap
Carry Case
USB Interface Cable
Versiv Open Source Software CD
AC Charger
2 x Quick Clean Cleaners (1.25/2.50 mm)
2 x SC/LC Multimode Launch Cables-50 µm
2 x SC/LC Singlemode Launch Cables-9 µm
2 x OTDR Source Port Interchangeable LC Adapters
USB Fiber Inspection Video Probe with 4 Tips
SC/SC Simplex Adaptor
2 x Launch Fiber Hanging Straps and Magnets
Statement of Calibration and Getting Started Guides