The CyberPower OR500LCDRM1U is a 1U rackmount UPS rated for 500VA/300W, with an LCD, automatic voltage regulation, and six outlets—four with battery backup and surge protection and two with surge protection only. It suits small network, telecom, or workstation setups that need compact rack power protection.
Recommended For
- Home-lab and small-network owners fitting a UPS into a shallow 19-inch rack who want short-outage backup for a router, switch, modem, or similar equipment.
- Small-office or departmental IT teams protecting a modest server or workstation load that fits within 300W and needs time for a brief outage or controlled shutdown.
- NAS and home-server operators who want a rack-mounted backup with USB-based power management for monitoring and shutdown during an outage.
- Network or telecom users in areas with brief voltage dips who want AVR to regulate minor power fluctuations without switching to battery.
Real-World Use Scenarios
- In a small network rack, a user can connect a modem, router, firewall, or switch to battery-backed outlets so brief power interruptions are less likely to drop the network; available backup time depends on the total load.
- For a small office server or workstation, the UPS can provide a short window during an outage to save work or initiate a controlled shutdown through its USB connection and PowerPanel software; it is intended for brief backup, not extended operation.
- In a compact equipment rack, a user can mount the UPS alongside essential network or telecom gear and reserve battery backup for the devices that need to stay on; the remaining outlets provide surge protection only.
- Where household or office power has minor dips or fluctuations, the UPS can regulate the incoming voltage without switching to battery for every small change, helping connected equipment continue running through those disturbances.
- At a small point-of-sale station, a user can put a compatible terminal and essential networking equipment on battery-backed outlets to reduce interruptions during brief outages; runtime will be shorter as the connected load increases.
Spec Summary
| Attribute | Value |
|---|
| Best For | Rack-mounted electronics that need battery backup and surge protection, including PCs and home-theater equipment |
|---|
| Power Capacity And Output | 500VA/300W capacity with 120V AC output, regulated to ±5% |
|---|
| Input And Plug | 90–140V AC input range, 57–63Hz input frequency, and NEMA 5-15P connector |
|---|
| Outlets And Protection | Six NEMA 5-15R outlets: four battery- and surge-protected and two surge-only; 1030-joule surge rating with RJ11/45 combo data-line protection |
|---|
| Battery And Runtime | Sealed lead-acid battery with 8-hour recharge; runtime is 60 minutes at 40W, 12 minutes at 150W, and 3 minutes at 300W |
|---|
| Rackmount And Dimensions | 1U rackmount form factor; 17.25 × 1.75 × 9.25 inches and 18 lb |
|---|
| Monitoring And Power Management | Front-panel LCD displays UPS status and power diagnostics; PowerPanel software supports power management, with USB and serial DB9 interface ports |
|---|
| Power Conditioning And Alerts | Automatic voltage regulation, GreenPower UPS, EMI/RFI filtering, LED status indicators, audible alarms, and a resettable circuit breaker |
|---|
| Model And Compliance | CyberPower Smart App Intelligent LCD Rackmount GreenPower UPS, model OR500LCDRM1U; UL 1778, cUL, and FCC DOC Class B |
|---|
Reference Q&A
Q: CyberPower OR500LCDRM1U vs OR700LCDRM1U: which should I choose?
A: Choose the OR500LCDRM1U for a rackmount load of up to 300 W; choose the OR700LCDRM1U when you need capacity for up to 400 W. Both are 1U Smart App LCD models with six outlets, line-interactive topology, simulated sine-wave output, and AVR.
Q: Should I get the OR500LCDRM1U or OR1000LCDRM1U for a 1U rack?
A: The OR500LCDRM1U is a fit for a 1U rack load up to 300 W. Choose the OR1000LCDRM1U when the connected equipment needs up to 600 W; both models are 1U rackmount units with six outlets and simulated sine-wave output.
Q: OR500LCDRM1U vs OR1500LCDRT2U: which is better for a small rack setup?
A: Choose the OR500LCDRM1U when a 1U rackmount format and a load up to 300 W suit the setup. The OR1500LCDRT2U is a 2U rack/tower model rated for up to 900 W, with eight battery- and surge-protected outlets, for setups that need more capacity or outlets.
Q: How long will this UPS keep my equipment running during an outage?
A: Runtime depends on the total connected load. The listed estimates are about 12 minutes at 150 W and 3 minutes at 300 W; a lighter load may run longer, but the exact time depends on the equipment and battery condition.
Q: Is this UPS suitable for rack-mounted network or server equipment?
A: It is a 1U rackmount UPS rated for up to 500 VA/300 W, with four battery-backed outlets and two surge-only outlets. It is suited to compatible, lower-power rack equipment, but its short runtime at higher loads makes it better for brief outages or shutdown time than extended operation.
Q: Can I replace the battery when it wears out?
A: Yes. The battery is user-replaceable. It uses a sealed lead-acid battery, so check the unit’s documentation for the correct replacement before ordering.
Q: Do all six outlets provide battery backup?
A: No. Four outlets provide battery backup and surge protection; the other two provide surge protection only. Connect equipment that must stay powered during an outage to one of the four battery-backed outlets.
Q: Is the OR500LCDRM1U suitable for a small network rack?
A: It may suit a compact rack with networking equipment and a modest power draw. Reddit users describe using it in short-depth racks and with network gear, but check your equipment’s combined wattage: the UPS is rated for up to 300W.
Q: How do I know whether 500VA/300W is enough for my equipment?
A: Add up the connected equipment’s actual wattage and keep the total within the 300W limit. Runtime falls as load rises: the supplied specifications estimate about 12 minutes at 150W and 3 minutes at 300W. A Reddit user seeking more capacity after adding rack devices illustrates why checking the load matters.
Q: Can the battery be replaced without replacing the whole UPS?
A: Yes. CyberPower’s battery-replacement video specifically lists the OR500LCDRM1U and identifies its battery pack as RB0670X2. Verify the compatible pack for your unit and follow the model’s safety instructions before replacing it.
Q: Is this a good choice for keeping equipment running through a long outage?
A: It is better suited to short outages or time for an orderly shutdown than to extended backup. The supplied estimates range from about 60 minutes at 40W to 3 minutes at 300W; actual runtime depends on load and battery condition. Reddit discussions also describe using it to protect network equipment during intermittent outages.