PERFORMANCE
Pulses per revolution 600
Measuring step 90° electronically/pulses
Measuring step deviation ± 18° / pulses per revolution
Error limits ± 54° / pulses per revolution
Duty cycle = 0.5 ± 5 %
Initialization time < 3 ms
ELECTRICAL DATA
Electrical interface 7 V ... 30 V, HTL/Push pull
Connection type Cable, 8-wire, universal, 0.5 m
Operating current = 50 mA
Power consumption = 0.5 W (without load)
Load current = 30 mA
Output frequency = 300 kHz
Reference signal, number 1
Reference signal, position 90°, electric, logically gated with A and B
Reverse polarity protection ?
Short-circuit protection of the outputs ? 1)
MTTFd: mean time to dangerous failure 600 years (EN ISO 13849-1) 2)
MECHANICAL DATA
Mechanical design Solid shaft, face mount flange
Shaft diameter 8 mm x 15.5 mm
Weight 180 g (with connecting cable)
Shaft material Stainless steel
Flange material Aluminum
Housing material Aluminum
Material, cable PVC
Start up torque 0.9 Ncm (+20 °C)
Operating torque 0.6 Ncm (+20 °C)
Permissible shaft loading radial/axial
30 N (axial)
50 N (radial)
Operating speed 6,000 min?¹ 1)
Maximum operating speed 8,000 min?¹ 2)
Moment of inertia of the rotor 0.65 gcm²
Bearing lifetime 2 x 10^9 revolutions
Angular acceleration = 500,000 rad/s²