Safety integrity level
SIL3 (IEC 61508) 1)
SILCL3 (EN 62061) 1)
Category Category 4 (EN ISO 13849) 1)
Performance level PL e (EN ISO 13849) 1)
B10d parameter
1.26 x 106 switching cycles (AC-15, 230 V, I = 1.5 A)
5.9 x 106 switching cycles (AC-15, 230 V, I = 0.75 A)
4.35 x 105 switching cycles (DC-13, 24 V, I = 2.5 A)
1 x 107 switching cycles (DC-13, 24 V, I = 0.63 A)
PFHD (mean probability of a dangerous failure per hour) 3.0 x 10-8 (EN ISO 13849)
TM (mission time) 20 years (EN ISO 13849)
INTERFACES
Connection type Fixed screw terminals
Number of enable current (N/O) contacts 3, relevant for safety
Voltage supply B1-B2/B3-B4
Output circuit > 25 V AC / 60 V DC PELV
Output circuit = 25 V AC / 60 V DC PELV or SELV
Power consumption 2.4 W (DC)
Overvoltage category III (see operating instructions)
Rated insulation voltage Ui 300 V AC
Rated impulse withstand voltage Uimp 4 kV
Test voltage 2 kV (50 Hz) (EN 60439-1)
Dimensions (W x H x D) 22.5 mm x 114 mm x 96.5 mm
Weight 0.2 kg