ETCR2800KB Split-core Ground Resistance Detector 0.010O~100O
Notice:
The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.
At the same time, please forgive us that we are unable to provide the English user manual. If you need it, please contact the customer service after purchase.
Thanks for your support!
Product Main Function
1. On - line monitoring the earth resistance of grounding system
2. Measure Range: 0.010O~100O
3. No need to disconnect the grounding down lead and no need with auxiliary electrodes
4. Rain and dust proof, can be installed and used in outdoor
5. Network system can be built to realize real-time detection and remote monitoring
6. EX-Mark: Exia?BT3Ga
7. Explosion Proof Certification: CE18.2332X
ETCR2800B Earth Resistance On - line Detector is high-tech product that "grounding resistance detection technology research" , specially design and manufacture for online monitoring grounding down lead connection status, circuit grounding resistance and metal circuit connection resistance. ETCR2800B is closed loop structure, convenient and efficient. On-line testing, non-contact measurement, grounding wire pass through the perforation of the detector, definitely not influence grounding for lightening effect and normal operation, real time on-line testing. Use by RS485 wire communication or GPRS wireless communication data transmission, realize remote online monitoring .Detector built-in sensor and circuit board, completely sealed, ensure high-accuracy, high stability and high reliability of long time on-line monitoring at field and indoors.
ETCR2800B Earth Resistance On - line Detector suitable for transmission line tower grounding; Meteorological lightning protection grounding; Petrochemical grounding; Communication grounding; Substation grounding; Railway facilities grounding; Construction warehouse grounding; Metal circuit resistance; Electrical equipment grounding etc.
ETCR2800B Earth Resistance On - line Detector could set up wired and wireless network system. Wired network system through RS485 communication protocol to transmit data, build up by the detector, ?communicator, monitoring software, power adapter, computer(above equipment need the user provide and secondary development) ?and other components; Suitable for short-distance ground resistance monitoring. Wireless network system through GPRS communication protocol to transmit data , build up by the detector(built-in GPRS transceiver module), ?SIM communication card, monitoring software, power adapter, computer(above equipment need the user provide and secondary development)? and other components for long-distance ground resistance monitoring. Wired network system is suitable for monitoring within 1,500 meters distance, wireless network system is not subject to distance restrictions.
Technical Parameter
Function Description
Function Return circuit grounding resistance on-line monitoring, metal return circuit resistance connection online monitoring, grounding condition monitoring.
CT structure Closed loop
Power Supply Detector:6VDC~12VDC,50mA Max(GPRS 12VDC 150mA Max). (Ui:6V;Ii:50mA;Ci:0µF;Li:0mH;Pi:0.1W)(User supply),
Instrument and safety barrier matching relation:Uo=Ui,Io=Ii,Po=Pi,Co=Ci,Lo=Li
Resistance Range 0.01O~100O
Resolution 0.001O
Accuracy ±2%rdg±3dgt(20?±5?,below 70%RH)
CT Size 56mm X 26mm
Overflow Indication test data>100O, system software or LCD display “OLO” symbol;
Connection line 1pcs ,1 meter cord(5 core wire)
Connection Identifier Red/brown---power supply input anode;
Black--- power supply input cathode;
Blue---RS485 signal anode;
Grey---RS485 signal cathode;
White--- grounding wire shield
(power supply input cathode can connects with analog grounding by short circuit connection)
Communication Method Wired network: RS485 communication protocol(support MODBUS)
Wireless network: RS485 or GPRS communication protocol(support MODBUS)
Network Points Wired network: 1 ~ 250 grounding points, scalable
Wireless network: 60000 grounding points, can be expanded
Communication distance Wired network: about 1500m,scalable
Wireless network: not limited
Alarm Indication the detector sound-light alarm
Alarm Setting System Software Settings
Data Display None
Dimensions Detector: 125mm × 119mm × 80mm
Weight Detector: 1KG
Working Temperature And Humidity -20?~55? ; 20%RH~90%RH
Humidors Error Within 5%
S hift Automatic shift
Grounding Lead Interference Current Should be avoid
External Magnetic Field <40A/m
External Electric Field <1V/m
Single Measurement time About 0.5 second
Working current Detector: 50mA Max.(GPRS: 12VDC 150mA Max)
Explosion-proof mark Ex ia ?B T3 Ga
Explosion-proof Certification CE18.2332X.
Protection Level IP54
Power Supply Mode External power supply (Equipped by user)
ETCR2800KB Accessories:
Detector
Fix Screw
RS485 Communication Wire
Warranty card/Qualification card
Paper Box