ETCR9220 H/L Voltage Clamp Current Meter 0.00mA~60.0A CT Size f68mm

  • ETCR9220 H/L Voltage Clamp Current Meter 0.00mA~60.0A CT Size f68mm
+
+
Overview
Specs
Reviews
ETCR9220 H/L Voltage Clamp Current Meter 0.00mA~60.0A CT Size f68mm
Notice:
  The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.
At the same time, please forgive us that we are unable to provide the English user manual. If you need it, please contact the customer service after purchase.
Thanks for your support!
Product Main Function
1. Measurement of H/L voltage AC leakage current (operate with insulation rod above 600V)
2. Range : 0.00mA~60.0A
3. Resolution : 0.01mA
4. Data Storage : 99 groups
5. Line Voltage : Test of the wire with insulation skin below 60kV, test of  bare wire below 35kV (operate with insulation rod)
6. CT Size :f68mm
   ETCR 9220 H/L Voltage Clamp Current Meter adopts CT  technology and mask digital integration technology, the instrument composed of special clamp current meter and  high voltage insulation rod, If not use  insulation rod, which can be used as high accuracy low voltage clamp current meter.
      ETCR 9220 H/L Voltage Clamp Current Meter connect with insulation rod, which can use for hight voltage line current measurement of   the wire with insulation skin below 60KV or  bare wire below 35KV, online current measurements, also with peak hold, data hold and data storage and so on function, the special clamp current meter convenient to clamp or withdraw the tested wire operate by push or pull back the insulation rod.It is widely used in substations, power plants, industrial and mining enterprises, inspection stations, electrical maintenance departments for current detection and electrical field operations. It can replace the H/L voltage transformation ratio tester, which can measure the H/L voltage current of the primary circuit and the secondary circuit respectively, and then calculate the H/L voltage transformation ratio. The insulation rod is handiness, and has the characteristics of moisture-proof, high temperature resistance, impact resistance, bending resistance, high insulation, scalable and so on.
Technical Parameter
Function Description
 Function  Measurement of H/L voltage AC leakage current
 Power Supply  DC 6V (LR03×4 alkaline dry batteries)
 Measurement Method  Clamp CT, integration method, the instrument can be hung on the line to test, more convenient to operation
 CT Size  f68mm
 Range  0.00mA~60.0A(50/60Hz automatic)
 Resolution  0.01mA
 Shift  0.00A~60.0A automatic shift
 Accurac(23?±5?RH<80%)  0.00mA~999mA:±1%±5dgt
 1.00A~60.0A:±1.5%±5dgt
 Sampling Rate  2 time/second
 Display Mode  4-digit LCD display
 LCD Size  Detector: 35mm×21.5mm
 Meter Size  Detector: 135mm×218mm×60mm
 Data Storage  99 groups , stored process display MEM symbol, “FULL” symbol display indicate that storage full
 PEAK Hold  Automatically hold the highest test value,In usual test mode, press PEAK key The "PE" symbol is displayed in the upper right corner of the LCD to keep data, Press the PEAK key again to cancel this function.
 Line Voltage  Below 60kV current test with insulated skin wire; below 35kV bare wire test (operate with insulation rods)
 Data Hold  In general test mode, press HOLD key to hold data, “DH” symbol display. press HOLD Key once again to cancel this function
 Data Access  “MR” symbol indication, can access all storage data
 Overflow Display  Exceed measure range overflow function: “OL A” symbol display
 Automatic Shutdown  15 minutes after boot up, the meter shuts down automatically without any operation, to reduce battery consumption
 Batter Voltage  When battery voltage is lower than 4.8V, display low battery voltage symbol “ ”, and remind to replace the battery
 Weight  3930g including insulation rod and battery
 Working Environment  -10?~40?; Below 80%rh
 Store Environment  -10?~60?; Below 70%rh
 Interference  Should avoid extremely strong electromagnetic fields, avoid 315MHz, 433MHz same-frequency signal interference
 Insulation Rod Dimension  f32mm,1m×5PCS
 Insulation Rod Withstand Voltage  Detcetor/Receiver: AC 2kV/rms ( between the out shell screws)
AC110kV/rms(all 5pcs insulation rod connect, between the two ends) 
 Structure  Anti-Dripping Type II
Package  Outer Package  Carton
Inner Package  Cloth bag
 Accessory   Detector  1 PCS
Insulation Rod(1M)  5 PCS
Tool Bag  1 PCS
Manual  1 PCS
Certificate  1 PCS
Warranty Card  1 PCS

Warranty & Returns

Warranty, Returns, And Additional Information

Return Policies*

  • Return for refund within: 30 days
  • Return for replacement within: non-replaceable
  • This item is covered by FeiPengLin Return Policy
  • *Subject to applicable law
  • Warranty Notice:

    This product does not include manufacturer warranty when purchased or used outside of its designated sales region. By purchasing internationally, you acknowledge that warranty support from the manufacturer will not be available.

Manufacturer Contact Info

LOADING...