FEATURES Housing Rectangular Housing Standard Dimensions (W x H x D) 80 mm x 105 mm x 40 mm Sensing range Sn 60 mm Safe sensing range Sa 48.6 mm Installation type Non-flush Switching frequency 4 Hz Connection type Terminal connection with M20 gland Switching output PNP / NPN Output function NC or NO Output characteristic Wire configurable Electrical wiring AC/DC 2-wire Enclosure rating IP65 1) MECHANICS/ELECTRONICS Supply voltage 20 V AC/DC... 250 V AC/DC Voltage drop = 6.5 V (AC) Hysteresis 1 %... 15 % Reproducibility = 10 % 1) 2) 3) Temperature drift (of Sr) ± 10 % EMC As per EN 55011, class B According to EN 60947-5-2 Continuous current Ia = 350 mA 4) = 250 mA 5) = 100 mA 6) Off-state current = 2.5 mA (AC 250 V) Minimum load current > 5 mA Short-time withstand current 2.2 A 7) Cable gland clamping area M20 1.5 Wire size = 2.5 mm2 Short-circuit protection – 8) Shock and vibration resistance 30 g, 11 ms / 10.