ETCR3200C Double Clamp Multi-function Earth Resistance Tester CT Size F70mm
Product Main Function
1. 2/3/4-wire method measure earth resistance,Range: 0.00O ~ 30.00kO
2. Selection method meausre earth resistance, Range: 0.00O ~ 3000O
3. Doule clamp method measure earth resistance,Range: 0.00O~100O
4. Soil resistivity measurement, Range: 0.00Om ~ 9000kOm
5. Earth voltage measurement,Range: AC 0.0 ~ 100.0V
6. AC current measurement, Range: 0.0mA ~ 600.0A
7. Data storage: 2000 sets
8. Alarm function: audible and visual alarm
9. CT size: F70mm
10. Waterproof case + Super large capacity lithium battery
ETCR3200C Double Clamp Multi-function Grounding Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. Apply digital processing technology, precision 4-wire method, 3-wire method and simple 2-wire method, selection method, double-clamp method to measure grounding resistance; Large caliber clamp design can measure the grounding system which using large grounding down lead, and can flexibly and accurately measure any grounding resistance value of various complex grounding conditions such as single point and mesh grounding. It is not necessary to disconnect any parallel grounding pole to measurement, maximize the convenience of measurement. Import FFT (Fast Fourier Transform) technology, AFC (Automatic Frequency Control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for long-term measurement. The tester case is made of waterproof protection box, anti-collision, anti-drop, waterproof (protection grade IP65), strong and durable, and also equipped with a large-capacity rechargeable lithium battery pack, especially suitable for outdoor construction. Widely used in power, telecommunications, meteorology, oil fields, construction, lightning protection and industrial electrical equipment, such as grounding resistance, soil resistivity, grounding voltage, alternating current, leakage current measurement.
Technical Specifications
Function Description
Power Supply DC7.4V 2600mAh rechargeable lithium battery
2/3/4-wire Method Measure Earth Resistance Range:0.00O~300KO; Resolution:0.01O; Accuracy:±2%rdg±3dgt
Selection Method Measure Earth Resistance Range:0.00O~3000O; Resolution:0.01O; Accuracy:±2%rdg±3dgt
Double Clamp Method Measure Earth Resistance Range:0.00O~100O; Resolution:0.01O; Accuracy:±10%rdg±5dgt
Earth Voltage Measurement Range:0.0~100.0V AC; Resolution:0.1V; Accuracy:±2%rdg±3dgt
Earth current Measurement Range:0.0mA~600.0A Resolution:0.00mA; Accuracy:±2%rdg±3dgt
Soil Resistivity Measurement (?) Range:0.00Om~9000KOm; Resolution:0.01Om
CT Size f70mm
Short-circuit Test Current AC 250mA max
Open-circuit Test Current AC 40V max
Test Frequency 128Hz/111Hz/105Hz/94Hz(AFC)
Data Storage 2000 groups
Automatic Shutdown 15 Minutes after power on, will automatic shut down without any operation
LCD Dimension LCD Frame Dimension: 128mm×75mm; LCD Display Dimension:124mm×67mm
Tester Dimension 280mm(L)×260mm(W)×160mm(H)
Total Weight 6700g(include package)
Working Current Standby: around 25mA (Backlight close); Measurement:100mA (Backlight close)
Test Wires Red 20m, black 20m, yellow 10m, green 10m, red 1.6m, black 1.6m (total 6 pcs wires)
Auxiliary Ground Rod 4PCS, f10mm×150mm
USB Interface With USB interface, software monitoring, storage data can be uploaded to computer, saved and printed
Bluetooth Communication Support the bluetooth communication function of Android system, after installation the APP, mobile terminals can be used to testing operations and view test records
Alarm Function Measure value exceed alarm setting value, will "Toot-toot-toot" alarm indication
Battery Voltage While battery voltage decreases to around DC 7.2V±0.1V, will display low battery voltage symbol“”, and remind to replace the battery
Accessories Tester:1PC;Current Clamp Sensor:2PCS; Ground Rod:4PCS; Testing wires:6PCS; USB communication cable :1PCS; Special charger: 1PCS; Tester bag:1PCS
Intrinsic error and performance indicators under base conditions
Measurement Function Measurement Range Intrinsic Error Resolution
2/3/4 pole method measure earth resistance(Re) DC resistance(R--) 0.00O-29.99O ±2%rdg±5dgt 0.01O
30.0O-299.9O ±2%rdg±3dgt 0.1O
300O-2999O ±2%rdg±3dgt 1O
3.00kO-300kO ±4%rdg±3dgt 10O
Selection method measure grounding resistance(Re) 0.00O-29.99O ±2%rdg±5dgt 0.01O
30.0O-299.9O ±2%rdg±3dgt 0.1O
300O-3000O ±2%rdg±3dgt 1O
Double clamp method measure grounding resistance(Re) 0.01O-0.99O ±10%rdg±5dgt 0.01O
1.0O-29.9O 0.1O
30O-100O 1O
Soil Resistivity(?)
0.00Om-99.99Om Accuracy:According to the precision of R (?=2paR, a:1 m-100m,p=3.14) 0.01Om
100.0Om-999.9Om 0.1Om
1000Om-9999Om 1Om
10.00kOm-99.99kOm 10Om
100.0kOm-999.9kOm 100Om
1000kOm-9000kOm 1kOm
Earth Voltage(50Hz/60Hz) AC 0.0-100.0V ±2%rdg±3dgt 0.1V
Alternatingcurrent(50Hz/60Hz) 0.0mA-600.0A ±2%rdg±3dgt 0.01mA
Meter 1 PCS
Meter Bag 1 PCS
Auxiliary Grounding Rod 4 PCS
Test Wires 4PCS (Red 20m; Yellow: 10m; Green: 10m; Black:20m)
Simple Test Wires 2 PCS (Red 1.6m; Black 1.6m)
Current Clamp 2 PCS
Monitoring sortware CD 1 COPY
USB Communication Cable 1 PCS
Special Charger 1 PCS
Manul/Warranty Card/Certificate 1 SET