ETCR6800 Clamp Leakage Current Meter
Product Main Function
1. Measurement of AC current, leakage current, Range:AC 0.00mA~1200A
2. Data Storage: 99 groups
3. Peak Hold
4. Line Voltage: below 600V
5. CT Size: F68mm
ETCR6800 High Accuracy Clamp Leakage Current Meter suitable for measuring AC current and leakage current below 600V, range: 0.00mA~1200A, CT size: F68mm, the iron core adopts magnetic shielding technology, almost unaffected by the external magnetic field, strong anti-interference ability. Especially suitable for high accuracy small current measurement, adopt non-contact current measurement, safe and simple operation.The instrument is small size, high accuracy, performance stable and function perfect, which is one of the necessary tools for electrician safety inspection and maintenance.
The instrument with data hold, data storage and other functions, can store 99 groups of data, the instrument connect computer by RS232 interface, stotage data can be uploaded to the computer, easy to read, analysis, save, print and so on.
Function
Measurement of AC leakage current, AC current and on-line AC current.
Power Supply
Alkaline dry battery 6LR61 9V,continues working 80 hours(Battery not included)
CT Size
f68mm
Range
0.00mA~1200A
Resolution
0.01mA
Accuracy
(23?±3?,
below 70%RH)
0.00mA~59.9A: ±1.5%±5dgt
60.0A~199A: ±2%±5dgt
200A~599A: ±3%±5dgt
600A~1200A: ±4%±5dgt
Test Mode
Clamp CT, integration method
Display Mode
4digits LCD display
Meter Size
224mm×115mm×43mm
LCD Size
35mm×21.5mm;display area:32mm×15mm
Sampling Rate
about 2 times/s
Shift
Automatically
Line Voltage
Line measurement below DC 600V
USB Interface
With USB interface, storage data can upload to computer, software monitoring
USB Cable Length
1.5m
Data Storage
99 groups, display FULL symbol indicate storage full
Peak Hold
Peak capture and hold function, long pressHOLD key and not release can display peak value in measurement.
Data Hold
Data hold function:DH symbol display
Overflow display
Exceed measure range overflow function:OL symbol display
Auto Shut Down
5 Minutes after power on, the meter shuts down automatically without any operation to reduce battery consumption
Battery Voltage
While battery voltage decreases to around 7.2V, will display low battery voltage symbol“ ”, and remind to replace the battery
Meter Weight
500g
Working Current
5mA
Working Temperature
-10? ~ 40?,below 80%rh
Storage Temperature
-10? ~60?,below 70%rh
Insulating Strength
AC 2KV/rms (between the core and outside shell)
Suitable Safety Standard
IEC1010-1?IEC1010-2-032?pollution, etc 2?CAT?(600V)