ETCR9500B Wireless High Voltage Current Transformation Ratio Tester

  • ETCR9500B Wireless High Voltage Current Transformation Ratio Tester
+
+
Overview
Specs
Reviews
ETCR9500B Wireless HV Transformation Ratio Tester

Product Main Function

1. Measurement of H/L voltage current transducer, transformer primary and secondary circuit current, transformation ratio, polarity and phase adjustment

2. Transformation Ratio Measurement Range:1~500

3. Transformation Ratio Resolution :0.1

4. Primary Current Test Accuracy :

5. Range:0.0A~800A;Resolution:0.1; Accuracy:±0.5%FS

6. Secondary Current Test Accuracy :
7. Range:0.00mA~5A;Resolution:0.01mA;Accuracy:±0.5%FS

8. Primary Current Clamp Size:f48mm

9. Secondary Current Clamp Size :f8mm

ETCR9500B Wireless HV Transformation Ratio Tester special designed and manufactured for online measurement of current transducer, transformaer primary current and secondary current, transformation ratio, phase and polarity judgment below 35kV in operation. The product is composed of primary current clamp (high voltage detector), secondary current clamp, host machine, high voltage insulation rod, monitoring software, communication cable, etc. the test data of primary current clamp adopt wireless to transmt which transmission distance of 100 meters.

The current clamp is made of high performance permalloy with magnetic shielding technology, which is almost free from the influence of the external magnetic field, ensuring the long time uninterrupted monitoring of high accuracy, high stability and high reliability. The host LCD display clear, with large storage space, can store 3000 groups of data. the hight voltage detector connect with 5pcs insulation rod, which can use for hight voltage line current measurement of the wire with insulation skin below 60KV or bare wire below 35KV, high voltage current clamp have unique automatic plug and pull structure, by pressing or pulling out the insulation rod can be easy to clamp or withdraw the tested wire, saving time and more effective. It is widely used in substations, power plants, industrial and mining enterprises, inspection stations, electrical maintenance departments for current detection and electrical field operations. The insulation rod is handiness, and has the characteristics of moisture-proof, high temperature resistance, impact resistance, bending resistance, high insulation, scalable and so on. insulation level 110KV.

The monitoring software has the functions of online real-time monitoring and historical query, dynamic display, maximum, minimum and average indication, alarm value setting and alarm indication, and with historical data reading, accessing, saving, printing and other functions. ETCR9500B Wireless HV Transformation Ratio Tester, at the same time: H/L voltage clamp current meter, high altitude current telemeter and other products functions.


Function H/L voltage current transducer, transformer primary and secondary circuit current, transformation ratio, polarity and phase adjustment
Power Supply DC 6VLR03(1.5V AAA×4)(Battery does not include)
Test Mode Clamp CT
Primary Current Test Accuracy

Range:0.0A~800A;Resolution:0.1; Accuracy:±0.5%FS

Secondary Current Test Accuracy

Range:0.00mA~5A;Resolution:0.01mA;Accuracy:±0.5%FS

Transformation Ratio Measurement Range

1~500

Transformation Ratio Resolution 0.1
Primary HV Current Clamp Size
Jaw Size: f48mm

Out Shape Size: 76mm×255mm×31mm

Secondary LV Current Clap Size

Jaw Size: f8mm

Out Shape Size: 137mm×40mm×19.5mm

Shift Automatic shifting
Sampling Rate

2 times/second
Data Storage
3000 groups, Press the left arrow key to keep the data and store automatically (Power down or replace the battery will not lose data)

Data Hold Press left arrow key to hold data in test mode, “HOLD” symbol display, press HOLD key again to cancel hold function
Data Access

Press the right arrow key enter into data access mode

Overflow Display

Exceed measure range overflow function: “OL” symbol display

No Signal Indication

When the receiver has not received transmit signal, dynamic display “no- -”symbol.

Auto Shut Down 15 minutes after boot up, the meter shuts down automatically without any operation
Battery Voltage

When battery voltage is lower than 4.8V, low battery voltage symbol will display and remind to replace battery.

Primary Current Clamp Transmission Distance
Wireless transmission distance 100M

Secondary Current Clamp Connection Cable Length

2M

Display Mode LCD:128dots×64dots With backlight function, suitable for dark places
LCD Size Display area :44mm×27mm
Host Size 78mm×165mm×42mm
Meter Weight 5 kg (with insulation rod and toolkit )
External Interference Avoid 315MHz, 433MHz Same-frequency Signal Interference
Working Temperature -10?~40?;below 70%rh
Store Temperature -10?~60?;below 70%rh
Insulation Rod Size F32mm,1m/pcs(5pcs)
Insulation Rod withstand voltage 110kv
Insulation Strength Host and detector:AC1000V/rms(between the shell and screws)

Warranty & Returns

Warranty, Returns, And Additional Information

Return Policies*

  • Return for refund within: 30 days
  • This item is covered by Talualuaz Return Policy
  • *Subject to applicable law
  • Warranty Notice:

    This product does not include manufacturer warranty when purchased or used outside of its designated sales region. By purchasing internationally, you acknowledge that warranty support from the manufacturer will not be available.

Manufacturer Contact Info

LOADING...