ETCR9550B Wireless H/L Voltage Transformation Ratio Tester
Notice:
The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.
At the same time, please forgive us that we are unable to provide the English user manual. If you need it, please contact the customer service after purchase.
Thanks for your support!
Product Main Function
1. Measurement of H/L voltage current transducer, transformer primary and secondary circuit current, transformation ratio, polarity and phase adjustment
2. Transformation Ratio Measurement Range:1~500
3. Transformation Ratio Resolution :0.1
4. Primary Current Test Accuracy :Range:0.0A~800A;Resolution:0.1; Accuracy:±0.5%FS(23?±3?,below 70%RH,the detected is in the center position of the clamp);
6. Secondary Current Test Accuracy : Range:0.00mA~5A;Resolution:0.01mA;Accuracy:±0.5%FS
ETCR9550B Wireless H/L Voltage Transformation Ratio Tester special designed and manufactured for online measurement of current transducer, transformaer primary current and secondary current, transformation ratio, phase and polarity judgment below 35kV in operation. The product is composed of primary current clamp (high voltage detector), secondary current clamp, host machine, high voltage insulation rod, monitoring software, communication cable, etc. the test data of primary current clamp adopt wireless to transmt which transmission distance of 100 meters.
The current clamp is made of high performance permalloy with magnetic shielding technology, which is almost free from the influence of the external magnetic field, ensuring the long time uninterrupted monitoring of high accuracy, high stability and high reliability. The host LCD display clear, with large storage space, can store 3000 groups of data. the hight voltage detector connect with 5pcs insulation rod, which can use for hight voltage line current measurement of the wire with insulation skin below 60KV or bare wire below 35KV, high voltage current clamp have unique automatic plug and pull structure, by pressing or pulling out the insulation rod can be easy to clamp or withdraw the tested wire, saving time and more effective. It is widely used in substations, power plants, industrial and mining enterprises, inspection stations, electrical maintenance departments for current detection and electrical field operations. The insulation rod is handiness, and has the characteristics of moisture-proof, high temperature resistance, impact resistance, bending resistance, high insulation, scalable and so on. insulation level 110KV.
The monitoring software has the functions of online real-time monitoring and historical query, dynamic display, maximum, minimum and average indication, alarm value setting and alarm indication, and with historical data reading, accessing, saving, printing and other functions. ETCR9550B Wireless H/L Voltage Transformation Ratio Tester, at the same time: H/L voltage clamp current meter, high altitude current telemeter and other products functions.
Technical Parameter
Function Description
Fuction H/L voltage current transducer, transformer primary and secondary circuit current, transformation ratio, polarity and phase adjustment
Power Supply DC6V alkaline batteries (1.5V AAA × 4)
Test Mode Clamp CT
Primary HV Current Clamp Test Accuracy Range:0.0A~800A;Resolution:0.1A; Accuracy:±0.5%FS (23?±3?,below 70% RH,the detected is in the center position of the clamp);
Primary Flexible Current Clamp Test Accuracy Range:0.0A~3000A;Resolution:0.1A; Accuracy:±1.0%FS
Secondary Current Test Accuracy Range:0.00mA~5A;Resolution:0.01mA;Accuracy:±0.5%FS
Transformation Ratio Measurement Range 1~500
Transformation Ratio Resolution 0.1
Angle Error Test Accuracy Range:0~360°;Accuracy:±3°
Shift Automatic shifting
Sampling Rate 2 times/second
Data Storage 3000 groups, Press the left arrow key to keep the data and store automatically (Power down or replace the battery will not lose data)
Data Hold Press HOLD key to hold data, press “HOLD” key once again cancel the hold function
Data Access Press HOLD key+ POWER key enter into data access mode
Overflow Display Exceed measure range overflow function: “OL” symbol display
No Signal Indication When the receiver has not received transmit signal, dynamic display “no- -”symbol
Automatic Shutdown 15 minutes after boot up, the meter shuts down automatically without any operation
Battery Voltage When battery voltage is lower than 5.2V±0.3V, low battery voltage symbol will display and remind to replace battery.
Display Mode LCD:128dots×64dots; with backlight function, suitable for dark places
LCD Size 44mm×27mm
Host Size 78mm×165mm×42mm;
Primary HV Current Clamp Size Jaw Size: f48mm; Out Shape Size: 76mm×255mm×31mm
Primary Flexible Current Clamp Size Jaw Size: f200mm; Out Shape Size: 200mm×245mm×13mm
Secondary LV Current Clamp Size Jaw Size: f8mm; Out Shape Size: 137mm×40mm×19.5mm
Primary Current Clamp Transmission Distance Wireless transmission distance 100m
Current Clamp Connection Cable Length 2M
Meter Weight 5kg (include insulation rod and battery)
External Interference Should avoid extremely strong electromagnetic fields, avoid 315MHz, 433MHz same-frequency signal interference
Working Temperature -25?~45?;below 80%rh
Store Temperature -10?~60?;below 70%rh
Insulation Rod Dimension ?32mm, 1m/pcs×5pcs
Insulation Rod Withstand Voltage 110kv
Insulation Streigth Host and Detector:AC1000V/rms(between the shell and screws)
Related Series Model
Model Description Primary HV Current Clamp Primary Flexible Current Clamp Secondary LV Current Clamp
ETCR9500B Wireless HV Transformation Ratio Tester Have None Have
ETCR9550B Wireless H/LVoltage Transformation Ratio Tester Have Have Have
Host 1 PCS
Primary HV Current Clamp 1 PCS
Primary Flexible Current Clamp 1PCS
Secondary LV current clamp 1 PCS
Insulation rod(1M) 5 PCS
USB Communication cable 1 PCS
Tool Bag 1 PCS
Manual 1 PCS
Certificate 1 PCS
Warranty Card 1 PCS