Shipped by Zienroylein
Operation Instructions:
Press "+" the LED displays the low voltage protection parameter. Hold on the "+" to enter setting manual to set the protection parameter
Press "-" will display the difference value. Hold on the "-" to enter setting manual to set the difference value.
For example
if you want the battery to stop outputting when the battery voltage is lower than 11V and re-output when it is over 11.6V. What should you need to do?
Hold on "+" and set the value as 11. The LED starts flashing. After the flashing stops, hold on "-" and set the difference value as 0.6V
Is it lower than 12.5V and the voltage is higher than 14.8V? Long press + screen flashing to set the stop value to 12.5,wait for the screen to not flash,press and hold - the screen flashes,set the hysteresis voltage to 2.3V.
Specifications:
Input Voltage Range: DC12-36V
Control Accuracy: 0.1V
Compatible Battery: lead acid, lithium ion battery, solar panel battery
Board Size: 57 X 42 X 19mm/2.24 X 1.65 X 0.75inch(L*W*H)
Package:
3pcs XH-M609 DC 12V-36V Battery Low Voltage Disconnect Protection Module
Warranty Notice:
This product does not include manufacturer warranty when purchased or used outside of its designated sales region. By purchasing internationally, you acknowledge that warranty support from the manufacturer will not be available.