MY2600D Current Clamp - a good AC DC current clamp meter

This dc amp meter is a stable, safe and reliable instrument. The circuit design is based on the core of micro-intelligent dual integrated A/D converter IC, equipped with comprehensive overload protection circuit, novel and can be used to measure 600A AC/DC current, 600V AC/DC voltage, frequency, resistance, capacitance, diode, continuity and so on.
Safety Standard
This dc amp clamp meter is designed and manufactured in accordance with safety standards IEC61010, IEC61010-2-032, double insulation CAT III 600V and pollution class 2.
Hints
Since the probe on the test lead has an insulator cover. Before taking a measurement, simply grab the insulator cover and rotate it, it will come off so you can easily plug it into a household outlet.
To measure current, you need to clip the meter to one of the wires, not the entire power cord. The power cord contains two fire wires and a ground conductor. The current in the two conductors always flows in opposite directions, so the magnetic fields of the two conductors cancel each other out and the meter reads 0A.
Some of the features - to meet your needs
NCV Detection: The amp meter clamp ac/dc has a non-contact voltage test with an audible and visual alarm. If the indicator light is on, it means that there is voltage tage, please pay attention to your safety!
HOLD function: The HOLD function records the currently displayed measurement value in the display so that you can read or record it at your leisure.
Automatic shutdown: If the multimeter tester is not used for 15 minutes, it switches off automatically.
Multi-function Amp Meter Tester

Automatic shutdown
If the clamp meter does not operate for 15 minutes, it will turn off automatically.

Hold function
The multimeter with amp clamp has a hold function that allows the currently displayed measurement value to be retained in the display so that it can be read or recorded at any time.

Multi-function
The dc current meter accurately measure capacitance, resistance, diodes, and continuity, making them ideal for laboratory, factory, and home use.
DC clamp amp meter temperature measurement

Clamp meter AC/DC current, with temperature measurement function, measuring temperature range up to -50°C ~ 1300°C (-58 °F ~ 2372 °F), its measurement temperature range is wider, can better meet your needs


DC Ampere Meter Overview
![]() MAYILON MY2022B Digital Clamp Meter T-RMS 6000 Counts Multimeter Voltage Test... | ![]() MAYILON MY2600C Clamp Meter AC 600A Amp Meter, 4000 Counts Digital Multimeter... | ![]() MAYILON HT206D Clamp Meter, T-RMS Multimeter AC/DC Current Voltage Tester 600... | ![]() MAYILON HT208D Amp Meter clamp ac/dc,1000A True RMS multimeter Tester, 6000 C... | |
|---|---|---|---|---|
| Customer Reviews | — | — | — | — |
| Price | — no data | — | — no data | — no data |
| AC Current | 6A/60A/600A | 1A/40A/600A | 60A/600A | 60A/600A/1000A |
| AC Voltage | 6V/60V/600V | 4V/40V/400V/600V | 6V/60V/600V | 600mV/6V/60V/600V/750V |
| DC Current | 6A/60A/600A | no data | 60A/600A | 60A/600A/1000A |
| DC Voltage | 600mV/6V/60V/600V | 400mV/4V/40V/400V/600V | 600mV/6V/60V/600V | 600mV/6V/60V/600V/1000V |
| Capacitance | 6nF/600nF/6µF/60µF/600µF/6mF/60mF | 4nF/40nF/400nF/4?/40?/400?/4mF/40mF | 10nF/100nF/1µF/10µF/100µF/1mF/10mF/100mF | 10nF/100nF/1µF/10µF/100µF/1mF/10mF/100mF |
| Frequency | 9.999Hz/99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kHz/9.999MHz | no data | 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz | 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz |
| Resistance | 600O/6kO/60kO/600kO/6MO/60MO | 400O/4kO/40kO/400kO/4MO/40MO | 600O/6kO/60kO/600kO/6MO/60MO | 600O/6kO/60kO/600kO/6MO/60MO |
| Temperature | -50?~1300?/-58?~2372? | -40?-1000?/-40?-1832? | -40?~1000?/-40?~1832? | -40?~1000?/-40?~1832? |
| Duty Cycle | 0.1~99.9% | no data | 1%~99% | 1%~99% |
| Maximum Display | 6000 | 4000 | 6000 | 6000 |

MAYILON
Focusing on precision instruments for decades, we have meticulously manufactured electrical tools with high cost-effectivenes.
MY2600D Current Clamp - a good AC DC current clamp meter

This dc amp meter is a stable, safe and reliable instrument. The circuit design is based on the core of micro-intelligent dual integrated A/D converter IC, equipped with comprehensive overload protection circuit, novel and can be used to measure 600A AC/DC current, 600V AC/DC voltage, frequency, resistance, capacitance, diode, continuity and so on.
Safety Standard
This dc amp clamp meter is designed and manufactured in accordance with safety standards IEC61010, IEC61010-2-032, double insulation CAT III 600V and pollution class 2.
Hints
Since the probe on the test lead has an insulator cover. Before taking a measurement, simply grab the insulator cover and rotate it, it will come off so you can easily plug it into a household outlet.
To measure current, you need to clip the meter to one of the wires, not the entire power cord. The power cord contains two fire wires and a ground conductor. The current in the two conductors always flows in opposite directions, so the magnetic fields of the two conductors cancel each other out and the meter reads 0A.
Some of the features - to meet your needs
NCV Detection: The amp meter clamp ac/dc has a non-contact voltage test with an audible and visual alarm. If the indicator light is on, it means that there is voltage tage, please pay attention to your safety!
HOLD function: The HOLD function records the currently displayed measurement value in the display so that you can read or record it at your leisure.
Automatic shutdown: If the multimeter tester is not used for 15 minutes, it switches off automatically.
Multi-function Amp Meter Tester

Automatic shutdown
If the clamp meter does not operate for 15 minutes, it will turn off automatically.

Hold function
The multimeter with amp clamp has a hold function that allows the currently displayed measurement value to be retained in the display so that it can be read or recorded at any time.

Multi-function
The dc current meter accurately measure capacitance, resistance, diodes, and continuity, making them ideal for laboratory, factory, and home use.
DC clamp amp meter temperature measurement

Clamp meter AC/DC current, with temperature measurement function, measuring temperature range up to -50°C ~ 1300°C (-58 °F ~ 2372 °F), its measurement temperature range is wider, can better meet your needs


DC Ampere Meter Overview
| Maximum Display | 6000 |
| AC Current | 6A/60A/600A |
| AC Voltage | 6V/60V/600V |
| DC Current | 6A/60A/600A |
| DC Voltage | 600mV/6V/60V/600V |
| Duty Cycle | 0.1~99.9% |
| Temperature | -50?~1300?/-58?~2372? |
| Resistance | 600O/6kO/60kO/600kO/ 6MO/60MO |
| Capacitance | 6nF/600nF/6uF/60uF/600uF/6mF/ 60mF |
| Frequency | 9.999Hz/99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kHz/9.999MHz |
![]() MAYILON MY2022B Digital Clamp Meter T-RMS 6000 Counts Multimeter Voltage Test... | ![]() MAYILON MY2600C Clamp Meter AC 600A Amp Meter, 4000 Counts Digital Multimeter... | ![]() MAYILON HT206D Clamp Meter, T-RMS Multimeter AC/DC Current Voltage Tester 600... | ![]() MAYILON HT208D Amp Meter clamp ac/dc,1000A True RMS multimeter Tester, 6000 C... | |
|---|---|---|---|---|
| Customer Reviews | — | — | — | — |
| Price | — no data | — | — no data | — no data |
| AC Current | 6A/60A/600A | 1A/40A/600A | 60A/600A | 60A/600A/1000A |
| AC Voltage | 6V/60V/600V | 4V/40V/400V/600V | 6V/60V/600V | 600mV/6V/60V/600V/750V |
| DC Current | 6A/60A/600A | no data | 60A/600A | 60A/600A/1000A |
| DC Voltage | 600mV/6V/60V/600V | 400mV/4V/40V/400V/600V | 600mV/6V/60V/600V | 600mV/6V/60V/600V/1000V |
| Capacitance | 6nF/600nF/6µF/60µF/600µF/6mF/60mF | 4nF/40nF/400nF/4?/40?/400?/4mF/40mF | 10nF/100nF/1µF/10µF/100µF/1mF/10mF/100mF | 10nF/100nF/1µF/10µF/100µF/1mF/10mF/100mF |
| Frequency | 9.999Hz/99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kHz/9.999MHz | no data | 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz | 10Hz/100Hz/1kHz/10kHz/100kHz/1MHz/10MHz |
| Resistance | 600O/6kO/60kO/600kO/6MO/60MO | 400O/4kO/40kO/400kO/4MO/40MO | 600O/6kO/60kO/600kO/6MO/60MO | 600O/6kO/60kO/600kO/6MO/60MO |
| Temperature | -50?~1300?/-58?~2372? | -40?-1000?/-40?-1832? | -40?~1000?/-40?~1832? | -40?~1000?/-40?~1832? |
| Duty Cycle | 0.1~99.9% | no data | 1%~99% | 1%~99% |
| Maximum Display | 6000 | 4000 | 6000 | 6000 |
MAYILON