Skip to main content
Multi USB Charging Adapter Cable Kit, USB C to Ligh-ting Adapter Box | All-in-one Charging Adapter Kit USB A to Type C & Light-ning Adapter, 60W Fast Charging & Data Transfer Cable
  •  
  • $11.99 
  • $43.99
  • Free 30-day Returns
  • Sold by PowerixDxz

    Shipped by PowerixDxz

    Price alert
    Shop it at NeweggBusiness.

    Meet Your Seller

    Clamp Meter 4000 Counts Amp Meter for AC Current AC/DC Voltage 600A | TRMS Auto Range Digital Multimeter with Capacitance Continuity Resistance NCV Diode Test for Car Electric Cabinet

    • High Safety Rating:This clamp meter meets CAT III 600V safety standards, featuring overload protection and low voltage alerts. It activates an LED alarm for AC voltage between 90-1000V or live wires and displays "OL" during overload, ensuring safety in high-voltage environments and reliable operation
    • High Precision & Auto-Ranging:Neoteck digital clamp meter features a 4000-count display and True RMS (TRMS) technology, ensuring precise measurement of complex waveforms like those from inverters or drives. With a voltage accuracy of ±1.0%, it is ideal for troubleshooting household appliances, automotive circuits, or industrial equipment, minimizing errors
    • Multi-Functional Clamp Meter:This clamp tester measures 600A AC current, 600V AC/DC voltage, resistance, diode functionality, and continuity. It features a 1A low-current mode for precise low-power circuit detection, such as LED lighting or electronics, covering 90% of basic measurement needs and streamlining workflows
    • NCV & Temperature Measurement:This amp meter features non-contact voltage detection (NCV) and a 25mm clamp jaw, detecting 90-1000V AC voltage without direct contact, with audible and visual alarms for safety in tight spaces or low-light conditions. It also measures temperature via a thermocouple, covering -40°C to 1000°C, making it versatile for various applications
    +
    +
    Overview
    Specs
    Reviews
    avatar

    Any questions? Our AI mode will help you find out quickly.

    Versatile Clamp Meter for AC Current, Accurate AC/DC Voltage, Diode, Resistance

    multifunctional digital clamp meter

    Neoteck digital clamp meter is a highly versatile tool, capable of measuring AC current, AC/DC voltage, resistance, and diode functionality. With auto-ranging, NCV detection, and clamp measuring capabilities for troubleshooting electrical issues safely in various applications.

    Reasons for Inaccurate AC Current Measurement

    Both wires clamped together If you clamp both the live and neutral wires, their currents cancel out, giving a near-zero reading. Always clamp only one wire.
    Wire not centered The wire should be placed in the middle of the clamp opening. Off-center placement reduces accuracy.
    Clamp not fully closed Dirt or a loose hinge can cause a gap, giving weak readings. Close the clamp tightly. If you hear a noise, open and close it again. If the noise stays, clean the dirty surfaces.
    Wrong range selected If the manual range is set too high (e.g., 200A for a 0.5A current), the reading may appear very low or inaccurate. Use auto-range or select a lower range.
    Current is too small Some clamp meters have poor resolution at low currents (e.g., below 0.1A). Try wrapping the wire around the clamp several times and divide the reading by the number of wraps.
    Low battery A weak battery can cause erratic or incorrect readings. Replace the battery if needed.
    Nearby conductors cause error Strong magnetic fields from other current-carrying wires near the clamp can affect accuracy. Try to isolate the wire being measured.

    High Precision with Auto-Ranging for Accurate Readings

    digital clamp meter

    This clamp meter provides precise measurements with 4000 counts of auto-ranging, automatically selecting the appropriate decimal point for reliable AC/DC voltage, resistance, and AC current detection. Featuring True RMS (TRMS), it ensures accurate results without the need for manual adjustments.

    • Estimate current first. If you are not sure, start with the highest range, then switch to a lower range for a more accurate reading. Never measure large current on a small range – it can damage the meter.

    • Clamp only one wire – Never clamp both live and neutral together, or their currents will cancel out and the reading will be zero.

    • Because that "single wire" might still contain both live and neutral inside (like a power cord). Their currents cancel out. To get a reading, you must clamp onto one of the phase wires.

    • If the current is too small for your clamp meter, try this trick:Wrap the same wire around the clamp several times (e.g., 5 or 10 turns).Then divide the reading on the display by the number of turns.

    • Voltage is not measured with the clamp. You must use the test leads (red and black probes).

    Neoteck Multimeter Series for Home, Schools, Laboratories, Factories, etc..

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/31517678-ddc6-4704-ad80-c53359d6ddf9.__AC_SR200,225___.jpg

    4000 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/073bce5d-4e63-4209-86d4-b08258b3101d.__AC_SR200,225___.jpg

    6000 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/0ad9ec9d-9885-40a2-84e8-d55a0cb78ca9.__AC_SR200,225___.jpg

    9999 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/2795bad8-fc4a-4136-8e4e-466747537d30.__CR0,0,200,225_PT0_SX200_V1___.png

    2000 Counts Multimeter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/7add195c-9530-4c34-a3bf-5ffa2c2ebf32.__AC_SR200,225___.jpg

    6000 Counts Multimeter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/15c437ef-eaf6-4f6c-be4c-b4091dd997d7.__CR0,0,200,225_PT0_SX200_V1___.jpg

    6000 Counts Multimeter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/8a3daf83-17a2-4944-9fdc-6ba1d2a1bfec.__CR0,0,200,225_PT0_SX200_V1___.jpg

    4000 Counts Multimeter

    Customer Reviews
    Price
    Security Level
    CAT III 600V CAT III 600V CAT III 1000V CAT III 1000V CAT III 600V CAT II 600V CAT II 600V
    AC Current
    1A/40A/600A 6A/60A/800A 100A/600A/1000A 200uA/2000uA/20mA/200mA/10A 600uA/6000uA/60mA/600mA/6A/10A - -
    DC Current
    - 6A/60A/800A 100A/600A/1000A 200uA/2000uA/20mA/200mA/10A 600uA/6000uA/60mA/600mA/6A/10A - -
    AC Voltage
    4V/40V/400V/600V 600mV/6V/60V/600V 1V/10V/100V/750V 2V/20V/200V/600V 6V/60V/600V 10mV-600V 0.8-600V
    DC Voltage
    400mV/4V/40V/400V/600V 600mV/6V/60V/600V 1V/10V/100V/1000V 200mV/2V/20V/200V/600V 600mV/6V/60V/600V/600V 0.1mV-600V 0.8-600V
    Capacitance
    4nF - 40mF(7 Ranges) 60nF-60mF(7 Ranges) 10nF - 100mF(8 Ranges) 4uF-2000uF 60nF - 60mF (7 Ranges) 10nF- 40mF -
    Resistance/Frequency/DutyCycle
    Resistance Resistance/Frequency/DutyCycle Resistance/Frequency/DutyCycle Resistance/Frequency Resistance/Frequency Resistance/Frequency Resistance
    NCV/Continuity
    NCV/Continuity(=50O) NCV/Continuity(=50O±10O) NCV/Continuity(=50O±30O) Continuity NCV/Continuity NCV/Continuity NCV/Continuity
    Clamp Size
    26MM 26MM 40MM - - - -
    Power Source
    2 x 3V AAA Battery(Included) 2 x 3V AAA Battery(Included) 2 x 4.5V AAA Battery(Included) 1 x 9V Battery(Included) 2 x 1.5V AAA Battery(Included) 2 x 1.5V AAA Battery(Included) 2 x 1.5V AAA Battery(Included)
    Range Selection
    Auto Auto/Manual Auto/Manual Auto Auto/Manual Auto/Manual Auto
    Temperature Detection
    ? ? ? ? ? ? ?

    Versatile Clamp Meter for AC Current, Accurate AC/DC Voltage, Diode, Resistance

    multifunctional digital clamp meter

    Neoteck digital clamp meter is a highly versatile tool, capable of measuring AC current, AC/DC voltage, resistance, and diode functionality. With auto-ranging, NCV detection, and clamp measuring capabilities for troubleshooting electrical issues safely in various applications.

    Reasons for Inaccurate AC Current Measurement

    Both wires clamped together If you clamp both the live and neutral wires, their currents cancel out, giving a near-zero reading. Always clamp only one wire.
    Wire not centered The wire should be placed in the middle of the clamp opening. Off-center placement reduces accuracy.
    Clamp not fully closed Dirt or a loose hinge can cause a gap, giving weak readings. Close the clamp tightly. If you hear a noise, open and close it again. If the noise stays, clean the dirty surfaces.
    Wrong range selected If the manual range is set too high (e.g., 200A for a 0.5A current), the reading may appear very low or inaccurate. Use auto-range or select a lower range.
    Current is too small Some clamp meters have poor resolution at low currents (e.g., below 0.1A). Try wrapping the wire around the clamp several times and divide the reading by the number of wraps.
    Low battery A weak battery can cause erratic or incorrect readings. Replace the battery if needed.
    Nearby conductors cause error Strong magnetic fields from other current-carrying wires near the clamp can affect accuracy. Try to isolate the wire being measured.

    High Precision with Auto-Ranging for Accurate Readings

    digital clamp meter

    This clamp meter provides precise measurements with 4000 counts of auto-ranging, automatically selecting the appropriate decimal point for reliable AC/DC voltage, resistance, and AC current detection. Featuring True RMS (TRMS), it ensures accurate results without the need for manual adjustments.

    • Estimate current first. If you are not sure, start with the highest range, then switch to a lower range for a more accurate reading. Never measure large current on a small range – it can damage the meter.

    • Clamp only one wire – Never clamp both live and neutral together, or their currents will cancel out and the reading will be zero.

    • Because that "single wire" might still contain both live and neutral inside (like a power cord). Their currents cancel out. To get a reading, you must clamp onto one of the phase wires.

    • If the current is too small for your clamp meter, try this trick:Wrap the same wire around the clamp several times (e.g., 5 or 10 turns).Then divide the reading on the display by the number of turns.

    • Voltage is not measured with the clamp. You must use the test leads (red and black probes).

    Neoteck Multimeter Series for Home, Schools, Laboratories, Factories, etc..

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/31517678-ddc6-4704-ad80-c53359d6ddf9.__AC_SR200,225___.jpg

    4000 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/073bce5d-4e63-4209-86d4-b08258b3101d.__AC_SR200,225___.jpg

    6000 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/0ad9ec9d-9885-40a2-84e8-d55a0cb78ca9.__AC_SR200,225___.jpg

    9999 Counts Clamp Meter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/2795bad8-fc4a-4136-8e4e-466747537d30.__CR0,0,200,225_PT0_SX200_V1___.png

    2000 Counts Multimeter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/7add195c-9530-4c34-a3bf-5ffa2c2ebf32.__AC_SR200,225___.jpg

    6000 Counts Multimeter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/15c437ef-eaf6-4f6c-be4c-b4091dd997d7.__CR0,0,200,225_PT0_SX200_V1___.jpg

    6000 Counts Multimeter

    https://m.media-amazon.com/images/S/aplus-media-library-service-media/8a3daf83-17a2-4944-9fdc-6ba1d2a1bfec.__CR0,0,200,225_PT0_SX200_V1___.jpg

    4000 Counts Multimeter

    Customer Reviews
    Price
    Security Level
    CAT III 600V CAT III 600V CAT III 1000V CAT III 1000V CAT III 600V CAT II 600V CAT II 600V
    AC Current
    1A/40A/600A 6A/60A/800A 100A/600A/1000A 200uA/2000uA/20mA/200mA/10A 600uA/6000uA/60mA/600mA/6A/10A - -
    DC Current
    - 6A/60A/800A 100A/600A/1000A 200uA/2000uA/20mA/200mA/10A 600uA/6000uA/60mA/600mA/6A/10A - -
    AC Voltage
    4V/40V/400V/600V 600mV/6V/60V/600V 1V/10V/100V/750V 2V/20V/200V/600V 6V/60V/600V 10mV-600V 0.8-600V
    DC Voltage
    400mV/4V/40V/400V/600V 600mV/6V/60V/600V 1V/10V/100V/1000V 200mV/2V/20V/200V/600V 600mV/6V/60V/600V/600V 0.1mV-600V 0.8-600V
    Capacitance
    4nF - 40mF(7 Ranges) 60nF-60mF(7 Ranges) 10nF - 100mF(8 Ranges) 4uF-2000uF 60nF - 60mF (7 Ranges) 10nF- 40mF -
    Resistance/Frequency/DutyCycle
    Resistance Resistance/Frequency/DutyCycle Resistance/Frequency/DutyCycle Resistance/Frequency Resistance/Frequency Resistance/Frequency Resistance
    NCV/Continuity
    NCV/Continuity(=50O) NCV/Continuity(=50O±10O) NCV/Continuity(=50O±30O) Continuity NCV/Continuity NCV/Continuity NCV/Continuity
    Clamp Size
    26MM 26MM 40MM - - - -
    Power Source
    2 x 3V AAA Battery(Included) 2 x 3V AAA Battery(Included) 2 x 4.5V AAA Battery(Included) 1 x 9V Battery(Included) 2 x 1.5V AAA Battery(Included) 2 x 1.5V AAA Battery(Included) 2 x 1.5V AAA Battery(Included)
    Range Selection
    Auto Auto/Manual Auto/Manual Auto Auto/Manual Auto/Manual Auto
    Temperature Detection
    ? ? ? ? ? ? ?
    Clamp Meter 4000 Counts Amp Meter for AC Current AC/DC Voltage 600A | TRMS Auto Range Digital Multimeter with Capacitance Continuity Resistance NCV Diode Test for Car Electric Cabinet

    Warranty & Returns

    Warranty, Returns, And Additional Information

    Warranty

    • Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
    • CONTACT

    Return Policies

    • Return for refund within: 30 days
    • Return for replacement within: 45 days
    • This item is covered by PowerixDxz Return Policy

    Manufacturer Contact Info

    LOADING...