12/2 NM-B, Non-Metallic, Sheathed Cable, Residential Indoor Wire, Equivalent to (100Ft Cut)
- #12 AWG Residential Wire for Outlets, Switches and Other Loads
- Equivalent to Romex NM-B - Color of Wire May not be the Same as the Picture Shown.
- 600-Volt Maximum with an Allowable Ampacity of 20 Amps
+
+
Overview
Reviews
Any questions? Our AI beta will help you find out quickly.
Try me now
For Dry Locations up to 90 degrees Celsius or 194 degrees Farenheit. For Exposed and Concealed Applications.
Copper (Cu) Conductors
Applications:
Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant. Equivalent to Romex NM-B.
Standards:
Meets or exceeds all applicable ASTM specifications
UL Standard 83: Thermoplastic Insulated Wires and Cables
UL Standard 719: Non-Metallic Cables
Federal Specification A-A-59544 and requirements of the NEC
Voltage rating - 600 volts
Construction:
Insulation:
Color coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90C
Sheath:
30 mil color coded PVC sheath rated 90C is applied over the completed assembly
Specifications:
Size:
12 AWG
Number of Conductors:
2
PVC Insulation Thickness:
0.76 mm / 0.029 inches
Ground Wire Size:
10 AWG
Nylon Thickness:
0.13 mm / 0.005 inches
Nominal Cable Dimensions:
14.2 mm x 0.55 inches
Weight per Foot:
0.254 lbs
Allowable Ampacity:
20 Amps
Copper (Cu) Conductors
Applications:
Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads. Its applications are outlined in NEC 2008 and NEC 2011 Article 334. NM-B is rated at 600 volts and although it is rated at a conductor temperature of 90°C dry , its ampacity is limited to 60°C according to the NEC 2008 and NEC 2011. It may be fished through masonry or tile walls, where not exposed or subject to excessive moisture or dampness. NM-B cables are LEAD FREE and RoHS compliant. Equivalent to Romex NM-B.
Standards:
Meets or exceeds all applicable ASTM specifications
UL Standard 83: Thermoplastic Insulated Wires and Cables
UL Standard 719: Non-Metallic Cables
Federal Specification A-A-59544 and requirements of the NEC
Voltage rating - 600 volts
Construction:
Insulation:
Color coded polyvinyl chloride (PVC) compound with a nylon covering meeting the required thickness of Type THHN. Conductor insulation is rated 90C
Sheath:
30 mil color coded PVC sheath rated 90C is applied over the completed assembly
Specifications:
Size:
12 AWG
Number of Conductors:
2
PVC Insulation Thickness:
0.76 mm / 0.029 inches
Ground Wire Size:
10 AWG
Nylon Thickness:
0.13 mm / 0.005 inches
Nominal Cable Dimensions:
14.2 mm x 0.55 inches
Weight per Foot:
0.254 lbs
Allowable Ampacity:
20 Amps
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: 30 days
- This item is covered by MINGPIN YOUCHUANG E-COMMERCE LIMITED Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory
LOADING...