Digital Dissolved Oxygen Meter with ATC, High Accuracy Do Meter with 9.84ft Cable, 0-20mg/L Measurement Range, Portable Dissolved Oxygen Tester for Aquaculture, Aquarium, Hydroponics, Wastewater
- Professional Dissolved Oxygen Meter: DO meter LH-D701 features a 0.00-20.00mg/L full dissolved oxygen measurement range with 0.01mg/L high resolution and ±0.3mg/L accuracy for ultra-reliable readings. It simultaneously tests dissolved oxygen concentration, saturation (0.0-200.0%), and temperature (32-140). All-in-one design meets all your multi-dimensional water quality testing needs without extra instruments.
- Triple Compensation Technology: Equipped with manual atmospheric pressure compensation (60.0-110.0KPa) and manual salinity compensation (0.0-50.0g/L), paired with automatic temperature compensation (32-104). Effectively offsets environmental interference, ensures precise detection results in various water environments such as aquaculture, sewage treatment and water source monitoring, suitable for lab and field use.
+
+
Overview
Reviews
Any questions? Our AI beta will help you find out quickly.
Try me now
Ideal Design: Boasts a wide LCD screen with clear data display and intuitive operation prompts, plus high-brightness backlight for easy reading in dim light. Advanced 32-bit microprocessor technology enables one-click operation for data switching and saving. (Includes switching between Celsius and Fahrenheit). With IP65 environmental protection grade, this DO meter is waterproof, dustproof and anti-interference, durable for harsh outdoor humid and dusty detection environments.
Wide-Range Applications: High-Performance Portable Dissolved Oxygen Meter is an essential professional water quality testing tool for aquaculture, environmental monitoring, water supply & sewage treatment. Precisely tests tap water, swimming pool water, Aquarium, Fish Tank, hospital & domestic sewage for compliance with quality standards.
What You Gain: 1*Instrument, 9.84 ft SD02 dissolved oxygen electrode, 30mL electrolyte, spare membrane head + rubber ring, sandpaper, USB charging cable and user manual.
How to install the dissolved oxygen electrode correctly?
Rinse and dry the electrode and membrane head with pure water. Fill the head 3/4 full with electrolyte and screw it tight. Remove spilled electrolyte and check for air bubbles. Reinstall the head if bubbles are present.
Does the instrument need calibration before first use?
The zero-oxygen calibration is completed at the factory. For daily use, only full-scale calibration in air or oxygen-saturated water is required.
What types of calibration are supported?
This DO meter supports three calibration modes: zero-oxygen calibration, full-scale calibration and temperature calibration, which can meet different accuracy requirements.
What core compensation functions does this device have?
Built with comprehensive compensation functions including auto temperature, manual air pressure and salinity compensation. It works stably across environments and guarantees accurate measurement in diverse water bodies.
When do I need to set atmospheric pressure and salinity?
The default pressure is 101.3 KPa. Adjust it to match local air pressure for better accuracy. Set the salinity level accordingly when testing seawater or saline water to ensure valid compensation.
Wide-Range Applications: High-Performance Portable Dissolved Oxygen Meter is an essential professional water quality testing tool for aquaculture, environmental monitoring, water supply & sewage treatment. Precisely tests tap water, swimming pool water, Aquarium, Fish Tank, hospital & domestic sewage for compliance with quality standards.
What You Gain: 1*Instrument, 9.84 ft SD02 dissolved oxygen electrode, 30mL electrolyte, spare membrane head + rubber ring, sandpaper, USB charging cable and user manual.
How to install the dissolved oxygen electrode correctly?
Rinse and dry the electrode and membrane head with pure water. Fill the head 3/4 full with electrolyte and screw it tight. Remove spilled electrolyte and check for air bubbles. Reinstall the head if bubbles are present.
Does the instrument need calibration before first use?
The zero-oxygen calibration is completed at the factory. For daily use, only full-scale calibration in air or oxygen-saturated water is required.
What types of calibration are supported?
This DO meter supports three calibration modes: zero-oxygen calibration, full-scale calibration and temperature calibration, which can meet different accuracy requirements.
What core compensation functions does this device have?
Built with comprehensive compensation functions including auto temperature, manual air pressure and salinity compensation. It works stably across environments and guarantees accurate measurement in diverse water bodies.
When do I need to set atmospheric pressure and salinity?
The default pressure is 101.3 KPa. Adjust it to match local air pressure for better accuracy. Set the salinity level accordingly when testing seawater or saline water to ensure valid compensation.
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: 30 days
- This item is covered by Halo Electronics Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory
LOADING...