Skip to main content
  • $22.51
  • Free 45-day Returns
  • Ships from China.
    Price alert
    Shop it at NeweggBusiness.

    Digital Voltage Comparator 0-100V Voltage Measurement Control Voltage Measuring Charge Discharge Protection Overvoltage Undervoltage Overload Protection (12V)

    Limited time offer, ends 11/08 By PeakCircuit Technology

    • Digital Voltage Comparator module is a versatile voltage monitoring controller, using industrial grade microcontroller as the main control unit, wide measurement range, high accuracy.
    • Module carefully processed genuine quality components made of stable performance, it can be widely used in a variety of voltage measurement and control types of occasions. The controller 5 different preset function.
    • Users can set the upper limit voltage and the lower voltage limit; measuring range of DC 0-100V, measuring accuracy ±0.1V.
    • Increase automatic power saving feature, users can customize the settings; all set parameters can be automatically saved, set the content of non-volatile.
    • Module work voltage: DC 12V (nominal voltage should not exceed +/- 10%).
    +
    +
    Overview
    Specs
    Reviews

    Any questions? Ask CelesteSM will help you find out quickly.

    Parameters:

    Module work voltage: DC 12V (nominal voltage should not exceed +/- 10%).

    Current: less than 12V, 50mA (relay action not less than 12mA, turn off the display less than 3mA).

    Operating temperature: Recommended -20 -60 (the limits of -30 -70 ).

    Measuring range: 0-99.9V.

    load capacity:

    Normally open relay port maximum load capacity: DC 0-30V / 10A, AC 0-250V / 10A;

    Relay NC port maximum load capacity: DC 0-28V / 10A, AC 0-125V / 10A.


    Module interface:

    Module voltage inputs: a 4-wire interface, all the terminals are the interface, user-friendly;

    1, DC +: DC power positive;

    2, DC-: DC power supply negative;

    3, V +: measuring voltage positive electrode;

    4, V-: measure negative voltage.


    Function Module:

    The user can select from the following five kinds of functions in one, you can set and save function parameters are automatically saved parameter set, power-down is not lost.

    Function1: Voltage measurement: this function is selected, the relay will not operate, digital display of the current measurement voltage.

    Function 2: Charge monitoring: When the measured voltage falls below a preset voltage V1 and V2 in the lower one, relay, voltage V1 and V2 higher than the higher of a relay off.

    Function3: Discharge Monitoring: When the measured voltage is higher than the preset voltage V1 and V2 higher one, relay, T1 and T2 voltage is lower than the lower one, the relay off.

    Function 4: pull the interval: When measuring the voltage between V1 and V2 between, relay, the relay off other cases.

    Function 5: interval outer pull: When the measured voltage falls below a preset voltage V1 and V2 in a lower or higher than the preset measuring a voltage higher voltages V1 and V2, the relay is energized; otherwise relay disconnect.

    Warranty & Returns

    Warranty, Returns, And Additional Information

    Warranty

    • Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
    • CONTACT

    Return Policies

    Manufacturer Contact Info

    LOADING...