Skip to main content
  • $43.99
  • Free 30-day Returns
  • Ships from China.
    Sold by EmpressTech

    Shipped by EmpressTech

    Price alert
    Shop it at NeweggBusiness.

    Meet Your Seller

    PMS5003 High Precision Laser Sensor to Detect Air Quality Digital Particle Concentration Laser Sensor

    • PMS5003 High Precision Laser Sensor to Detect Air Quality Digital Particle Concentration Laser Sensor; The PMS5003 is a digital general-purpose particulate matter concentration sensor that can be used to obtain the mass and quantity of suspended particulate matter in air per unit volume and output it as a digital interface; The sensor can be embedded into various instruments or environmental improvement equipment related to the concentration of suspended particulate matter in the air to provide timely and accurate concentration data; The sensor adopts the principle of laser scattering. This means that the laser light is scattered on the suspended particles in the air, and the scattered light is collected at a specific angle to obtain the curve of the scattered light intensity change with time.
    +
    +
    Overview
    Specs
    Reviews

    Any questions? Ask CelesteSM will help you find out quickly.

    Product description PMS5003 High Precision Laser Sensor to Detect Air Quality Digital Particle Concentration Laser Sensor Outputs The main outputs are the mass and number of particles of each concentration per unit volume, where the number of particles per unit volume is 0.1 litre and the mass concentration is in micrograms per cubic metre. The outputs are divided into two states: active and passive. After the sensor is powered on, the default state is active output, i. e., the sensor actively sends serial data to the host computer, with a time interval of 200-800ms, and the higher the concentration of particulate matter in the air, the shorter the time interval. The active output is divided into two modes: smooth mode and fast mode. When the concentration of particles in the air is small, the sensor outputs a smooth mode, i. e., it outputs the same set of values every three times, and the actual data update period is about 2 s. When the concentration of particles in the air is large, the sensor outputs are automatically switched to a fast mode, and each time the output is a new value, and the actual data update period is 200-800ms. Typical Circuit Connection The circuit should be designed with the following in mind
    1. The PMS5003 requires a 5V supply because the fan needs a 5V drive. However, the other data communication and control pins require 3.3V as a high level. However, all other data communication and control pins require 3.3V as high level. Therefore the main board MCU to which it communicates should be powered by 3.3V. If the motherboard MCU is supplied with 5V, a level shifter chip or a level converter should be added to the communication lines (RXD, TXD) and control lines (SET, RESET). If the motherboard MCU is 5V powered, a level shifter chip or circuit should be added to the communication (RXD, TXD) and control (SET, RESET) lines. 2. SET and RESET have internal pull-up resistors that should be left blank if not used. 3. 3. PIN7 and PIN8 are for internal debugging and should be left empty in the application circuit. 4.
    4. When applying the hibernation function, it should be noted that the fan stops working when hibernating, and it takes at least 30 seconds for the fan to restart. Therefore, in order to obtain accurate data, the sensor should not work for less than 30 seconds after waking up from hibernation. Therefore, in order to obtain accurate data, the sensor should not operate for less than 30 seconds after wake-up from sleep.
    Size Default Baud Rate: 9600bps
    Parity Bit: No
    Stop Bit: 1 bit
    Total protocol length: 32 bytes Starting symbol 1 0x42 (fixed) Start character 2 0x4d (fixed) Frame length high octet...... Frame length = 2x13 + 2 (data + parity bit) Frame length low octet...... Data 1 high octet...... *Data 1 indicates PM 1.0 concentration (CF=1, standardised particulate matter) in µg/m3 Data 1 Low Octet...... Data 2 High Octet...... Data 2 indicates PM 2.5 concentration (CF=1, standardised particulate matter) in µg/m3 Data 2 Low Octet...... Data 3 Upper Octet...... Data 3 indicates PM10 concentration (CF=1, standardised particulate matter) in g/m3 Data 3 Low Octet...... Data 4 Upper Octet...... *Data 4 indicates PM 1.0 concentration (in atmospheric conditions) in g/m3 Data 4 Low Octet...... Data 5 Upper Octet...... Data 5 indicates PM 2.5 concentration (atmospheric) in g/m3 Data 5 Low Octet......

    Data 6 Upper Octet...... Data 6 indicates PM10 concentration (atmospheric conditions) in g/m3. Data 6 Low Octet...... Data 7 Upper Octet...... Data 7 indicates the number of particles with a diameter of 0.3 m or more in 0.1 litre of air. Data 7 Low Octet...... Data 8 Upper Octet...... Data 8 indicates the number of particles above 0.5 m in 0.1 litre of air. Data 8 Low Octet...... Data 9 Upper Octet...... Data 9 indicates the number of particles above 1.0 m in 0.1 litre of air. Data 9 Low Octet...... Data 10 Upper Octet...... Data 10 indicates the number of particles above 2.5 m in 0.1 litre o

    Warranty & Returns

    Warranty, Returns, And Additional Information

    Warranty

    • Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
    • CONTACT

    Return Policies

    Manufacturer Contact Info

    LOADING...