DC 6-40V 4-Channel Digital Time Relay Timer Controller Delay Switch Module Independent Timing Cycle LCD Display
- Industrial LCD display, 4 keys for easy operation, with reset function.; High performance microcontroller for high stability, high reliability and low power consumption.; Reverse power protection function, avoiding surge current shock.; Each group of relay has common, normally open and normally closed contacts, 4 sets of conversion.; Four-channel time relay, adjustable timing range: 0.1 second to 9999 minutes(countdown), the total number of Loops is adjustable from 0 to 9999(zero for the infinite loop).; Effective signal input types of 4 channels can be set to high level and low level, rising edge and falling edge, etc. and can connect with external switch, PNP sensor and NPN sensor. The high level signal threshold value is adjustable from 0.1V to 40.0V.; Four channels of effective signal can be set to control four channels of time relay trigger to run, high level to maintain running, trigger reset and restart etc.; This controller is a 4-channel time relay; each channel of relay can run independently and it also can run in turn. It can be controlled by detecting four channels of input voltage signal to control four loads on/off independently or in turn, such as controlling four solenoid valves to work independently or work in turn, controlling four input signal to delay on/off, etc.
+
+
Overview
Specs
Reviews
Any questions? Ask CelesteSM will help you find out quickly.
Try me now
Features: Industrial LCD display, 4 keys for easy operation, with reset function. High performance microcontroller for high stability, high reliability and low power consumption. Reverse power protection function, avoiding surge current shock. Each group of relay has common, normally open and normally closed contacts, 4 sets of conversion. Four-channel time relay, adjustable
timing range: 0.1 second to 9999 minutes (countdown), the total number of Loops is adjustable from 0 to 9999 (zero for the infinite loop). Effective signal input types of 4 channels can be set to high level and low level, rising edge and falling edge, etc. and can connect with external switch, PNP sensor and NPN sensor. The high level signal threshold value is adjustable from 0.1V to 40.0V. Four channels of effective signal can be set to control four channels of time relay trigger to run, high level to maintain running, trigger reset and restart etc. User can set password to prevent others to change the setting parameters. All setting parameters can be saved after power off.
Range: 0.1 s - 9999min
Adjustable Cycle: 0 - 9999 times
Adjustable Working Power Supply: DC6-40V Four Signal Input Impedance > 100K
Input Signal Voltage Range: DC0-40V
Working Current: When backlight off current is about 9mA/12V( 0.11W ) 4
Relays Working Current: about 170mA/12V (2W) Four Set of Conversion (normally open and normally closed)
Contact Load: 10A/277V AC or 10A/30V
DC Contact Resistance: <=100m (1A 6V DC) Mechanical Durability: 10 million Electricity Durability: > 100, 000 (10A-250V AC)
Operating Temperature: -40~85°C
Item Size: 11 * 8.5 * 3.7 cm / 4.33 * 3.35 * 1.45 in
Item Weight: 196g / 6.92 oz
Package Size: 15 * 9.5 * 5cm / 5.91 * 3.74 * 1.97 in
Package Weight: 248g / 8.76 oz
Package List: 1 * Relay Module
timing range: 0.1 second to 9999 minutes (countdown), the total number of Loops is adjustable from 0 to 9999 (zero for the infinite loop). Effective signal input types of 4 channels can be set to high level and low level, rising edge and falling edge, etc. and can connect with external switch, PNP sensor and NPN sensor. The high level signal threshold value is adjustable from 0.1V to 40.0V. Four channels of effective signal can be set to control four channels of time relay trigger to run, high level to maintain running, trigger reset and restart etc. User can set password to prevent others to change the setting parameters. All setting parameters can be saved after power off.
Specifications
: TimingRange: 0.1 s - 9999min
Adjustable Cycle: 0 - 9999 times
Adjustable Working Power Supply: DC6-40V Four Signal Input Impedance > 100K
Input Signal Voltage Range: DC0-40V
Working Current: When backlight off current is about 9mA/12V( 0.11W ) 4
Relays Working Current: about 170mA/12V (2W) Four Set of Conversion (normally open and normally closed)
Contact Load: 10A/277V AC or 10A/30V
DC Contact Resistance: <=100m (1A 6V DC) Mechanical Durability: 10 million Electricity Durability: > 100, 000 (10A-250V AC)
Operating Temperature: -40~85°C
Item Size: 11 * 8.5 * 3.7 cm / 4.33 * 3.35 * 1.45 in
Item Weight: 196g / 6.92 oz
Package Size: 15 * 9.5 * 5cm / 5.91 * 3.74 * 1.97 in
Package Weight: 248g / 8.76 oz
Package List: 1 * Relay Module
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: 30 days
- This item is covered by EmpressTech Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory
LOADING...