Your Browsing History







Any questions? Our AI beta will help you find out quickly.
Feature
Specifications
| Function | ||
| DC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
| Basic accuracy | 0.025% | |
| AC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
| Basic accuracy | 0.4% (True-RMS) | |
| DC current | Range / resolution | 500.00 A, 5000.0 A, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| Basic accuracy | 0.05% | |
| AC current | Range / resolution | 500.00 A, 5000.0 A, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
| Basic accuracy | 0.6% (True-RMS) | |
| Temperature (excluding probe) | Range / resolution | -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) |
| Basic accuracy | 1.0% | |
| Resistance | Range / resolution | 50.000 , 500.00 , 5.0000 k, 50.000 k, 500.00 k, 5.0000 M, 50.00 M, 500.0 M |
| Basic accuracy | 0.05% | |
| Capacitance | Range / resolution | 1.000 nF,10.00 nF 100.0 nF, 1.000 F, 10.00 F, 100.0 F, 1000 F, 10.00 mF, 100 mF |
| Basic accuracy | 1.0% | |
| Frequency | Range / resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
| Basic accuracy | 0.005% | |
| Connectivity | Optional infrared connector via Fluke ir3000 FC | |
| General Specifications | ||
| Maximum voltage between any terminal and earth ground | 1000 V | |
| Battery type | 6 AA alkaline batteries, IECLR6 | |
| Battery life | 100 hours minimum, 200 hours in logging mode | |
| Temperature | Operating | -20°C to 55°C |
| Storage | -40°C to 60°C | |
| Relative humidity | 0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C) | |
| Electromagnetic compatibility | EMC EN613261 | |
| Vibration | Random vibration per MIL-PRF-28800F Class 2 | |
| Shock | 1 meter drop per IEC/EN 610101 3rd Edition | |
| Size (H x W x L) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | |
| Weight | 870.9 g (28 oz) | |
| Multiple on screen displays | Yes | |
| True-RMS AC bandwidth | 100 kHz | |
| dBV/dBm | Yes | |
| DC mV resolution | 1 V | |
| Megohm range | Up to 500 M | |
| Conductance | 50.00 nS | |
| Continuity beeper | Yes | |
| Battery/fuse access | Yes/Yes | |
| Elapse time clock | Yes | |
| Time of day clock | Yes | |
| Min-max-avg | Yes | |
| Duty cycle | Yes | |
| Pulse width | Yes | |
| Isolated optical interface | Yes | |
| Auto/touch hold | Yes | |
| Reading memory | Yes | |
| Log to PC | Yes | |
| Interval/event logging | Yes | |
| Logging memory | Up to 15,000 readings | |
| Wireless connectivity (optional) | Yes |