Digital Clamp Meter T-RMS 6000 Counts, Multimeter Voltage Tester Auto-ranging, Measures Current Voltage Temperature Capacitance Resistance Diodes Continuity Duty-Cycle (AC Clamp Meter)
Limited time offer, ends 07/29 By E-tech
- True-RMS clamp meter: This voltage meter can accurately measure AC Current, AC/DC Voltage, Frequency or Duty Cycle, Resistance, Capacitance and also provides Diode, Continuity and Temperature tests. True RMS for accurate measurements on non-linear loads. Easy to use for labs factories and household.
- LowZ & LPF: Low input impedance helps prevent false readings due to ghost voltage. Low Pass Filter (LPF) for accurate measurement of variable frequency drive signals when measuring motors and transformer.
- NCV Defection Function: Non-contact voltage detection effectively check electrical status through measuring EM field intensity without touching any wires; The NCV button lies on the right side.
- Multi-function: Backlit LCD Display - When the voltage > 80V, the current > 3A, the LCD backlit screen turns red to warn you of high voltage/LED Flashlight/Temperature Measurement for liquids and air conditioning ports included K-Type Thermocouple/Low Battery Indication/Auto power off after 15mins
+
+
Overview
Specs
Reviews
Any questions? Our AI beta will help you find out quickly.
Try me now
To measure Alternating Current
:
If current> 3A, the orange display lights up.
The measuring range of AC current is 6A/60A/600A.
Accuracy: ±( 2.5 %+5).
Note:
To measure the current you need to clamp the meter around one of the wires and not the whole power cord. The power cord contains two wires carrying current and ground wire. The current in two wires always flows in opposite directions, so the magnetic fields from two wires canceling each other, therefore the meter reads 0 A.
To measure AC/DC Voltage
:
Press the "FUNC. " key to change the AC or DC voltage measurement.
If the voltage is> 80 V, the orange display lights up.
The measuring range of AC voltage is 6V/60V/600V.
Accuracy: ±( 1.0 %+3).
The measuring range of DC voltage is 600mV/6V/60V/600V.
Accuracy: ±( 0.5 %+3).
Note:
The voltage value needs to be measured using test leads, the clamp cannot be used directly.
Grasp the individual current conductor to be measured and close the current clamp again. The measured conductor must be placed in the center of the clamp, otherwise, additional errors will occur.
Features:
Jaw Design
The Jaw is marked with maximum voltage and current measured value. Suitable for one-hand operation
Weight & Size
Weight: 260g.
Size: 7.5 x 2.8 x 1.3 inches.
Small and light, easy to carry when working.
AC Current Measurement
To measure the current, you only need to clamp the live wire rather than the whole power cord.
FUNC. Button Measurement
Press the "Func. " button to switch the respective secondary function between the different measurements such as between AC and DC.
Automatic Shutdown
No operation in 15 minutes, the clamp meter beeps 3 times. Without further operation, it beeps again and switches off automatically.
Multi-Function
Accurately measure resistance, capacitance, diode, continuity. Easy to use in laboratory factories and homes.
Specifications
:
If current> 3A, the orange display lights up.
The measuring range of AC current is 6A/60A/600A.
Accuracy: ±( 2.5 %+5).
Note:
To measure the current you need to clamp the meter around one of the wires and not the whole power cord. The power cord contains two wires carrying current and ground wire. The current in two wires always flows in opposite directions, so the magnetic fields from two wires canceling each other, therefore the meter reads 0 A.
To measure AC/DC Voltage
Specifications
:
Press the "FUNC. " key to change the AC or DC voltage measurement.
If the voltage is> 80 V, the orange display lights up.
The measuring range of AC voltage is 6V/60V/600V.
Accuracy: ±( 1.0 %+3).
The measuring range of DC voltage is 600mV/6V/60V/600V.
Accuracy: ±( 0.5 %+3).
Note:
The voltage value needs to be measured using test leads, the clamp cannot be used directly.
Grasp the individual current conductor to be measured and close the current clamp again. The measured conductor must be placed in the center of the clamp, otherwise, additional errors will occur.
Features:
Jaw Design
The Jaw is marked with maximum voltage and current measured value. Suitable for one-hand operation
Weight & Size
Weight: 260g.
Size: 7.5 x 2.8 x 1.3 inches.
Small and light, easy to carry when working.
AC Current Measurement
To measure the current, you only need to clamp the live wire rather than the whole power cord.
FUNC. Button Measurement
Press the "Func. " button to switch the respective secondary function between the different measurements such as between AC and DC.
Automatic Shutdown
No operation in 15 minutes, the clamp meter beeps 3 times. Without further operation, it beeps again and switches off automatically.
Multi-Function
Accurately measure resistance, capacitance, diode, continuity. Easy to use in laboratory factories and homes.
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: non-replaceable
- This item is covered by E-tech Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory
LOADING...