ZHONGPXY 275V Uc AC Surge Protector for 208Y/120V, 3P+N Type 2 DIN Rail SPD
- 3+1 Three-Phase Protection: This Type 2 SPD uses three MOV modules for the L1-N, L2-N, and L3-N paths, plus one GDT module for N-PE. The 3+1 configuration is intended for compatible three-phase systems with a neutral conductor
- 275V L-N and 255V N-PE Uc: The maximum continuous operating voltage is 275V AC on each L-N path and 255V AC on the N-PE path. Its voltage protection level is 1.5kV on both types of path
- 20kA In and 40kA Imax: Rated for a 20kA nominal discharge current and a 40kA maximum discharge current under an 8/20s waveform to help limit transient overvoltage in compatible low-voltage distribution systems
- Pluggable DIN Rail Design: Four replaceable protective modules and 35mm DIN-rail mounting suit compatible commercial distribution panels and industrial control cabinets. The pluggable design makes future module maintenance more convenient
- Visual Status and Remote Signaling: Green/red indicator windows provide an at-a-glance status check. COM-NC and COM-NO changeo
+
+
Overview
Specs
Reviews
Any questions? Ask CelesteSM will help you find out quickly.
Try me now
OverviewThe YDF40-275/3+1 (FM) Type 2 Surge Protective Device is designed to help limit transient overvoltage in compatible three-phase AC distribution systems. Its 3+1 configuration provides three L-N protection paths and one N-PE protection path. Pluggable modules, thermal disconnection, visual status indicators, and remote signaling support installation and ongoing maintenance. Features20kA nominal discharge current and 40kA maximum discharge current, both rated under an 8/20s waveform. Three MOV modules for the L1-N, L2-N, and L3-N paths, plus one GDT module for the N-PE path. Pluggable protective modules for convenient replacement during maintenance.
Response times of 25ns on L-N and 100ns on N-PE. Green status windows indicate normal operation; red indicates a fault. Remote signaling through COM-NC and COM-NO changeover contacts. UL94-V0 thermoplastic housing with an IP20 protection rating. Operating temperature range of -40C to +80C.
SpecificationsModel: YDF40-275/3+1 (FM)
Maximum continuous operating voltage (Uc): 275V AC on L-N; 255V AC on N-PENominal discharge current
In (8/20s): 20kAMaximum discharge current
Imax (8/20s): 40kAVoltage protection level
Up: 1.5 kV on L-N; 1.5 kV on
N-PEResponse time: 25ns on L-N; 100ns on
N-PEMaximum backup fuse: 125A
gL/gGMounting: 35mm
DIN railApplicable power systems: Three-phase TN and
TT systemsOperating temperature: -40C to +80CApplicationsSuitable applications may include compatible three-phase distribution panels, commercial electrical panels, and industrial control cabinets. The remote signaling contacts can be connected to a compatible monitoring circuit where status monitoring is needed. Confirm the system voltage, neutral and grounding arrangement, wiring paths, and installation requirements before selection. Installation and maintenance should be performed by a qualified electrician with power isolated.
Response times of 25ns on L-N and 100ns on N-PE. Green status windows indicate normal operation; red indicates a fault. Remote signaling through COM-NC and COM-NO changeover contacts. UL94-V0 thermoplastic housing with an IP20 protection rating. Operating temperature range of -40C to +80C.
SpecificationsModel: YDF40-275/3+1 (FM)
Maximum continuous operating voltage (Uc): 275V AC on L-N; 255V AC on N-PENominal discharge current
In (8/20s): 20kAMaximum discharge current
Imax (8/20s): 40kAVoltage protection level
Up: 1.5 kV on L-N; 1.5 kV on
N-PEResponse time: 25ns on L-N; 100ns on
N-PEMaximum backup fuse: 125A
gL/gGMounting: 35mm
DIN railApplicable power systems: Three-phase TN and
TT systemsOperating temperature: -40C to +80CApplicationsSuitable applications may include compatible three-phase distribution panels, commercial electrical panels, and industrial control cabinets. The remote signaling contacts can be connected to a compatible monitoring circuit where status monitoring is needed. Confirm the system voltage, neutral and grounding arrangement, wiring paths, and installation requirements before selection. Installation and maintenance should be performed by a qualified electrician with power isolated.
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: 30 days
- This item is covered by kaipuda Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory
LOADING...