Your Browsing History
- Free 30-day Returns
$255.28
Meet Your Seller
BLUE SEA 7622100 ML ACR CHARGING RELAY WITH MANUAL
+
+
Overview
Specs
Reviews
Any questions? Ask CelesteSM will help you find out quickly.
Try me now
BLUE SEA 7622100 ML ACR CHARGING RELAY WITH MANUAL7622100 ML ACR Charging Relay 12V 500A with Manual Control Deutsch Connector500 Amp magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine.
Features: Manual control switch provides an added level of safety allowing control with or without power, and offering LOCK OFF capability for servicingAutomatically manages the charging of two large battery banksAllows paralleling of battery banks for emergency starting500 Ampere continuous rating to support high-output alternatorsMagnetic Latch (ML) ACR draws very low current (<40mA to monitor terminal voltage) in the ON or OFF states, and draws moderate current for very short time when changing stateDual sensingsenses charge on both battery banksStart Isolation (SI) can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronicsEngine Isolation (EI) can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator outputSenses charging on two battery banksLED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation3/8-16 tin-plated copper studs for maximum conductivity and corrosion resistance7/8 (22mm) stud length accepts multiple cable terminalsSilver alloy contacts provide high reliability for switching live loadsLabel recesses for circuit identificationSpecifications: Control
Circuit Connection: Deutsch DTM
Nominal Voltage: 12VDC
Manual Control: YesEngine
Isolation:
YesMounting: #10Start
Assist: YesStart
Isolation: YesAmperage
Operating Current: 13mAAmperage
Operating Current When Changing State: < 7.0AT erminal
Stud Torque: 140 in-lb ( 15.82
Nm)Continuous Rating: 500AIntermittent
Rating: 700A (5 min) Cranking
Rating 30 Seconds: 1450A DCCable Size to
Meet Ratings: 2x (4/0)Live
Current Switching: 300A@12VDC
Switching Cycles: 100, 000Terminal Ring
Diameter Clearance: 1.18 ( 29.97 mm)Terminal
Stud Length: 0.875 ( 22.23 mm)Terminal
Stud Size: 3/8 - 16 (M10)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings. ca. gov.
Features: Manual control switch provides an added level of safety allowing control with or without power, and offering LOCK OFF capability for servicingAutomatically manages the charging of two large battery banksAllows paralleling of battery banks for emergency starting500 Ampere continuous rating to support high-output alternatorsMagnetic Latch (ML) ACR draws very low current (<40mA to monitor terminal voltage) in the ON or OFF states, and draws moderate current for very short time when changing stateDual sensingsenses charge on both battery banksStart Isolation (SI) can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronicsEngine Isolation (EI) can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator outputSenses charging on two battery banksLED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation3/8-16 tin-plated copper studs for maximum conductivity and corrosion resistance7/8 (22mm) stud length accepts multiple cable terminalsSilver alloy contacts provide high reliability for switching live loadsLabel recesses for circuit identificationSpecifications: Control
Circuit Connection: Deutsch DTM
Nominal Voltage: 12VDC
Manual Control: YesEngine
Isolation:
YesMounting: #10Start
Assist: YesStart
Isolation: YesAmperage
Operating Current: 13mAAmperage
Operating Current When Changing State: < 7.0AT erminal
Stud Torque: 140 in-lb ( 15.82
Nm)Continuous Rating: 500AIntermittent
Rating: 700A (5 min) Cranking
Rating 30 Seconds: 1450A DCCable Size to
Meet Ratings: 2x (4/0)Live
Current Switching: 300A@12VDC
Switching Cycles: 100, 000Terminal Ring
Diameter Clearance: 1.18 ( 29.97 mm)Terminal
Stud Length: 0.875 ( 22.23 mm)Terminal
Stud Size: 3/8 - 16 (M10)
WARNING: This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings. ca. gov.
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: non-replaceable
- This item is covered by NothingButSavings Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory
LOADING...