Your Browsing History
Meet Your Seller
100BALANCE UART to USB Cable 6pin GH1.25 for Smart Active Balance BMS
Limited time offer, ends 09/07 By Yihe Global Store
- This is a separate part; use it with a 100balance smart BMS or smart active balancer. When the minimum NTC temperature is below the heating start temperature (settable via the PC host) and a charger is connected, heating will be activated. When the minimum NTC temperature rises above the heating shutdown temperature (settable via the PC host), heating for charging is turned off. Abnormal status detection: if heating has been active for 15 minutes but the temperature has not increased by 2 degrees, heating is considered abnormal. Heating remains present. After 15 minutes, the system re-evaluates whether to resume heating. If heating has been active for 60 minutes but the temperature has not risen by 5 degrees, heating is deemed abnormal and exits. A re-check occurs after a few minutes to decide whether to restart heating
+
+
Overview
Specs
Reviews
Any questions? Our AI mode will help you find out quickly.
Try me now
This is a separate part; use it with a 100balance smart BMS or smart active balancer. When the minimum NTC temperature is below the heating start temperature (settable via the PC host) and a charger is connected, heating will be activated. When the minimum NTC temperature rises above the heating shutdown temperature (settable via the PC host), heating for charging is turned off.
Abnormal status detection: if heating has been active for 15 minutes but the temperature has not increased by 2 degrees, heating is considered abnormal. Heating remains present. After 15 minutes, the system re-evaluates whether to resume heating. If heating has been active for 60 minutes but the temperature has not risen by 5 degrees, heating is deemed abnormal and exits. A re-check occurs after a few minutes to decide whether to restart heating
Abnormal status detection: if heating has been active for 15 minutes but the temperature has not increased by 2 degrees, heating is considered abnormal. Heating remains present. After 15 minutes, the system re-evaluates whether to resume heating. If heating has been active for 60 minutes but the temperature has not risen by 5 degrees, heating is deemed abnormal and exits. A re-check occurs after a few minutes to decide whether to restart heating
Warranty & Returns
Warranty, Returns, And Additional Information
Warranty
- Please contact the Seller directly for warranty information. Warranty information may also be found on the Manufacturer's website.
- CONTACT
Return Policies
- Return for refund within: 30 days
- Return for replacement within: 30 days
- This item is covered by Yihe Global Store Return Policy
Manufacturer Contact Info
- For a directory of all our manufacturers, please click below.
- Manufacturers Directory
LOADING...













